Heater Casing :
It can’t be measured from the electronical card.
From the component:
Probes of the tester should be applied on to the related connectors as shown on the
pictures
Detergent dispenser :
It can’t be measured from the electronical card.
Probes of the tester should be applied on to the related connectors as shown on the
pictures
Regeneration valve:
From the electronical card:
CN2.10 – CN2.7
4130
Ω
± 10 (25 C º)
Sketch at the
.
23.95±15
Ω
1660
Ω
± 10 (25 C º)
ELECTRON
İ
CAL CARD
CONNECTORS
Sketch at the side show the
connectors of the regeneration
valve on the electronical card.
Probes of the tester should be
applied on to the related
connectors.
O
R
A
N
G
E
P
IN
K
CONNECTORS SHOULD BE MEASURED
57