![Russell Hobbs RHDW1 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/russell-hobbs/rhdw1/rhdw1_service-manual_1500893005.webp)
Capacitor
Heater Casing Group
•
Heater
Voltage 220/240 V
Total Power 2000 W
Resistance 23.19
Ω
±
٪
5
It is used to heat the washing water.
Heater is not active during the drying process.
It is assembled to the sump and located to the Supply side
of circulation pump.
2,5
µ
F – 450 V class P2
Capacitor is permanently connected to the
circulation pump coils.
Drain Pump
Voltage
220/240 Volt
Frequency
50 Hz
Total Power
30 W
Flowrate
17 – 21 lt/min
Coil Resistance
143
Ω
%± 7
Coil
İ
solation Class F
Thermal Protection
120 ° C
3