Allow to stand for a minimum of 3 hours before plugging in to the mains
The temperature in the appliance is controlled by the temperature
control knob located on the front face, at the bottom right hand side.
Rotate the control knob left or right to regulate the temperature inside
the freezer.
On the temperature control, 1 is the warmest setting and 6 is the coldest
setting. Under normal conditions the temperature control should be set
between 2 and 3. Once the temperature control has been set, close the
door and plug in the appliance. We recommend that the door is not
opened for a minimum of 4 hours to allow the appliance to reach the
standard operating temperature. The ‘OFF’ position is an automatic
shutdown, and it will defrost.
Note: The standard operating temperature for the freezer compartment
should be between -12
°
C and -30
°
C.
Indicator lights
Power
Indicates the freezer is switched on.
Run
Indicates the appliance is working. (The red indicator
light will switch on and off as required, this is normal)
Alarm
Indicates when the inside temperature of the appliance is
too high
How To Use and Temperature Selection