Selecting trigger mode 

Stand-alone routines can be automatically triggered or sound triggered.  
To select trigger mode:    
1.  Press MENU to enter the control menu. 
2.  Select SOUND MODE and press ENTER to confirm.  
3.  Use the UP and DOWN buttons to select ON for sound trigger or OFF for 

automatic trigger. Press ENTER to save the setting. 

4.  Press MENU to exit. 

Adjusting sound trigger level 

1.  Press MENU to enter the control menu. 
2.  Select SOUND SENSE and press ENTER to confirm. 
3.  Play the sound source (music beat, for example) at a typical volume. 

Press the UP button to increase microphone sensitivity or the DOWN 
button to decrease sensitivity. When sound triggering is satisfactory, press 
ENTER to save the setting.   

4.  Press MENU to exit. 

Master/slave operation 

Multiple fixtures can be operated in Show Mode without a controller using the 
master/slave function. You can select any convenient fixture to be the master 
fixture that controls the others. You set the remaining fixtures as slaves.  
There are 4 slave mode options that allow you to create dynamic effects 
among multiple fixtures. Fixtures set to SLAVE1 flash at the same time as the 
master. Fixtures set to SLAVE2, SLAVE3, and SLAVE4 flash with a timing 
delay that is determined by the show selection. SLAVE1 is the default setting. 
You can connect up to 32 fixtures using DMX cable to connect one fixture’s 
DMX OUT socket to the next fixture’s DMX IN socket. See ‘Control data link’ 
beginning on page 16 for more information about connecting fixtures. 
To set up the master fixture: 
1)  On the fixture selected to be the master, press MENU to enter the control 

menu. 

2)  Select MASTER/SLAVE. Press ENTER.  
3)  Press UP or DOWN to select MASTER. Press ENTER to save the setting.  
4)  Set the master fixture to run one of the stand-alone shows. See ‘Selecting 

a Show Mode routine’ on page 19.  

Содержание strobe cwl

Страница 1: ...Strobe CWL User Manual...

Страница 2: ...ability to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this document pertain...

Страница 3: ...ixture mounting bracket 11 AC power 12 Linking fixtures to power in a chain 13 Fixture overview 14 Tips for reliable data transmission 16 Connecting the DMX data link 16 Fixture setup 17 Using the con...

Страница 4: ...d do not view the light output with optical instruments or any device that may concentrate the beam This lighting fixture is for professional use only and must be installed by a qualified technician I...

Страница 5: ...nnected to ground earth Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Socket outlets or external po...

Страница 6: ...and Canada the cables must be UL listed type SJT or equivalent In the EU the cables must be type H05VV F or equivalent Suitable cables with Neutrik PowerCon connectors are available from Martin see Ac...

Страница 7: ...nu items are selected To minimize the risk of eye irritation or injury disconnect the fixture from power at all times when the fixture is not in use and provide well lit conditions to reduce the pupil...

Страница 8: ...n any way not described in this manual or install other than genuine RUSH by Martin parts Refer any service operation not described in this manual to a qualified technician Protection from epileptic s...

Страница 9: ...es The fixture is supplied with this user manual a 1 5 m 5 ft power cable local power plug not included on some versions and a mounting bracket Before using the product for the first time 1 Read Safet...

Страница 10: ...surface can be oriented at any angle Ensure that the mounting surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment they will support Mounting the fixt...

Страница 11: ...Loop the safety cable through the eye bolt on the fixture s rear panel and around the truss or other secure anchoring point See Accessories on page 29 for suitable safety cables Multiple fixture mount...

Страница 12: ...ble so that the fixtures can easily be disconnected from power Do not insert or remove live Neutrik PowerCon connectors to apply or cut power as this may cause arcing at the terminals that will damage...

Страница 13: ...16 A rated 14 AWG 1 5 mm2 throughput cables from Martin see Accessories on page 29 you can relay mains power from one fixture to another by connecting fixtures to power in a linked daisy chain MAINS O...

Страница 14: ...the rear panel in a fuse holder Replace only with one of the rating printed on the rear panel 3 Microphone The built in microphone provides sound triggered activation in Show Mode 4 Secondary attachme...

Страница 15: ...throughput using 5 pin cables 9 3 pin DMX input output For your convenience 3 pin XLR sockets are also provided for DMX input and output throughput using 3 pin cables In each case use either the 3 pin...

Страница 16: ...he 5 pin XLR connectors are not used in the fixture but are available for possible additional data signals as required by the DMX512 A standard Standard pin out is pin 4 data 2 cold and pin 5 data 2 h...

Страница 17: ...e start channel is the first channel used to receive instructions from a DMX controller Each DMX controlled fixture must have a DMX address set If a fixture that requires 4 DMX channels has its DMX ad...

Страница 18: ...ash To set the fixture s DMX mode 1 Press MENU to enter the control menu 2 Select CHANNEL MODE and press ENTER The present mode setting will blink on the display 3 Use the UP and DOWN buttons to selec...

Страница 19: ...r fixtures operating in master slave mode The following table describes the dynamic effects provided by the shows when 4 fixtures are set up as master slave 2 slave 3 and slave 4 Show Routine M Master...

Страница 20: ...w Mode without a controller using the master slave function You can select any convenient fixture to be the master fixture that controls the others You set the remaining fixtures as slaves There are 4...

Страница 21: ...Press ENTER 3 Press UP or DOWN to select a slave mode SLAVE1 SLAVE4 4 Press ENTER to save the setting 5 Set the DMX STATE setting to SHOW MODE See Behavior when DMX signal is not present on page 18 Ma...

Страница 22: ...3 Press MENU to exit Fixture operating hours readout To display the fixture s operating hours counter 1 Press MENU to enter the control menu 2 Select FIXTURE TIME and press ENTER The display will sho...

Страница 23: ...pecify precise cleaning intervals for the fixture Environmental factors that may result in a need for frequent cleaning include Use of smoke or fog machines High airflow rates near air conditioning ve...

Страница 24: ...with a new one of the specified type and rating only 4 Reinstall the fuse holder cap before reapplying power If the replacement fuse blows immediately disconnect the fixture from power and refer it to...

Страница 25: ...inuous blinder effect 4 channel mode Channel Value Function 1 0 5 Blackout 6 255 Flash intensity minimum to maximum 2 0 255 Flash duration minimum to maximum 3 0 5 No flash single flash with ch 1 6 25...

Страница 26: ...fixture in master slave mode Slave1 Slave fixture that flashes with master Slave2 Slave4 Slave fixture with timing delay Show Mode Show 0 Show 12 Random flash show 0 and 12 programmed shows See table...

Страница 27: ...e is set to the DMX address that is set on the controller Check that linked components all use standard DMX polarity Move fixture away from unshielded high voltage installation Fixture connected to DM...

Страница 28: ...blinder single flash Control and Programming Control options DMX stand alone master slave sound trigger DMX channels 1 or 4 Setting and addressing Control panel with LCD display Compliance USITT DMX51...

Страница 29: ...nal voltage Allow for a deviation of 10 PF Power Factor Thermal Cooling Forced air temperature regulated low noise Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta min 0 C...

Страница 30: ...ur unit bracket for RUSH Strobe CWL P N 91606019 Half coupler clamp P N 91602005 G clamp P N 91602003 Safety cable safe working load 50 kg P N 91604003 Related Items RUSH Software Uploader 1 P N 91611...

Страница 31: ......

Страница 32: ......

Отзывы: