background image

 

Table of Contents 

Table of Contents .......................................................... 2

 

Safety Information ......................................................... 2

 
 

Pre-installation .............................................................. 3

 

Planning Installation ................................................................3

 

Installation Options ..................................................................4

 

Tools required ..........................................................................4

 

Materials required ....................................................................4

 

Hardware Included ........................................................ 5

 

Package Contents ....................................................................5

 

Installation ..................................................................... 6

 

Specifications    .  ......    ....................................................... 9

   

.................................................9

 

DIMENSIONS                                               ........................9

 

Safety Information 

 

CFA-D150(BPT18-44A)

.............................................

1. Electric Service supply must be 120V 60Hz.
2. Follow all local safety and electrical codes as well as NEC (National Electrical Code) and the

OSHA(Occupational Safety and Health Act).

3. This unit must be properly grounded.
4. Always disconnect the power supply prior to servicing the fan, motor or junction box.
5. Do not bend or kink the power wires.
6. Do not install where the air temperature will exceed 40

°

C(104

°

F).

7. This ventilating fan is approved for use over a bathtub or shower when installed in a GFCI

protected circuit.

8. Do not use to exhaust hazardous or explosive vapors.
9. Do not install in a cooking area.

10. Use this unit in the manner intended by the manufacturer. If you have any questions please call

the manufacturer .Customer service number located on last page.

11. Installation work must be carried out by qualified person(s) in accordance to all local and safety

codes including the rulers for fire-rated construction.

12. Sufficient air supply is required for proper combustion and the exhausting of gases through the

chimney(flue) of fuel burning equipment to prevent back –drafting .See the standards of NFPA
(National Fire Protection Association ) and ASHRAE(American Society for Heating Refrigeration
and Air Conditioning Engineers) and the local building code authorities.

13. Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
14. Fans should always be vented to the exterior.
15. If this ventilating fan is installed over a tub or shower, it must be marked as approved for the

application.

16. Prior to service or cleaning this unit, shut off power supply at the panel and lock to prevent the

power from being turned on. If the panel cannot be locked clearly mark the panel with a warning
tag not to turn on the power.

17. Do not install in a ceiling with insulation greater than R40.
18. Ductwork should be installed in a straight line with minimum bends.
19. Duct work size must be a minimum of the discharge and should not be reduced.

20.

For UL: the fan is intended to be mounted at least 2.1m(7feet) above the floor.

Care and Cleaning......................................................... 10

Содержание BPT18-44A

Страница 1: ... BPT18 44A It is very important that you read this manual installation for your safety and efficiency of the unit Please be advised that all units should be installed by a licensed electrician READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...must be carried out by qualified person s in accordance to all local and safety codes including the rulers for fire rated construction 12 Sufficient air supply is required for proper combustion and the exhausting of gases through the chimney flue of fuel burning equipment to prevent back drafting See the standards of NFPA National Fire Protection Association and ASHRAE American Society for Heating...

Страница 3: ...the dimensions on page 12 to determine the required hole size for the ceiling The grill edges should overlap the finished ceiling NOTE If installing in existing construction you must have access to space above and below the installation location This unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Do not i...

Страница 4: ...ons possible for this ventilation fan Not all configurations are shown If your installation requires a variation other than those shown consult with a licensed contractor to determine the best installation for your project If you are replacing an existing fan ensure that the new grill will adequately cover the existing opening TOOLS REQUIRED Hammer Safety goggles Phillips screwdriver Level Electri...

Страница 5: ...e not shown to actual size Part Description Quantity AA Long wood screw M4x30 8 BB Short screw M4x12 2 CC Short screw M4x8 1 PACKAGE CONTENTS Part Description A Fan body B Grill C Suspension bracket I D Suspension bracket II E Suspension bracket III AA BB CC B ...

Страница 6: ...ions between 20 in and 24 in insert suspension brackets I C II D and III E Proceed to step 5 NOTE Sliding hanger bars are provided to allow for accurate positioning of the main body between joists Use four long wood screws AA to attach the main body of the fan to the ceiling joists Ensure the main body is level and square to the joists Tighten all screws CAUTION Do not mount the fan flush against ...

Страница 7: ...oist Secure the suspension brackets C D and E to the joist using long wood screws AA Ensure the main body is level and square to the joists Tighten all screws CAUTION Do not mount the fan flush against the joist The flange should be flush with the ceiling board Install a circular duct 1 to the outlet and secure Install the duct with a gradient of 1 2 to the outside 1 it with duct tape or clamps to...

Страница 8: ...ese colors determine what each house wire represents before connecting You may need to consult a licensed electrician to determine this safely Connect house wires to ventilation fan wires Match colors as shown black to black white to white and green to green using wire nuts not provided Replace the junction box cover Do not pinch the lead wires Use the spring clips to pinch mount and insert the gr...

Страница 9: ...5 Sone Power consumption Watts 42 W Speed 660 rpm Air deliver at 0 1 WG 150 cfm Weight 10 78 lbs 4 9 kg DIMENSIONS Ceiling opening length 10 8 in 27 4 cm Ceiling opening width 10 5 in 26 7 cm Ceiling opening depth 8 5 in 21 6 cm Housing dimension length 10 2 in 25 9 cm Housing dimension width 10 2 in 25 9 cm Housing dimension depth 8 0 in 20 30 cm ...

Страница 10: ...ove dust and dirt from the fan housing with a vacuum cleaner Dampen a cloth with dish detergent wipe the fan housing and dry with a cloth Replace the grill To reduce the risk of fire always vent fans to the exterior and in compliance with local codes Do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages Unplug or disconnect the appliance from the power supply bef...

Отзывы: