background image

Installation manual

WARNING

The machine must be installed and started for the first time by qualified personnel

authorized by RUPES Spa

Package handling instructions
The machine is supplied in a box with overall dimensions and weight of
70x54x90 (H) cm – 30kg
comprising:

-

wooden platform

-

corrugated cardboard covering

-

binding straps

The box must be handled and stored in an upright position. Do not place any objects on the package
that weigh more and/or have a different sized base than the box. Avoid knocking the package or
damaging it when it is being moved.

Instructions for unpacking and disposal of packaging
Before opening the box, carefully examine its appearance. If it is damaged, shows signs of having
been opened or the documentation in the envelope attached to the outside is not complete, do not
proceed but send the box back to the sender taking suitable measures. Failure to do so will render
the warranty void.
To unpack the machine:
-

cut the binding straps;

-

remove the corrugated cardboard covering

Take the machine off the wooden platform
Take the key to open the inspection door
Set aside the bag of accessories

Inspection of package contents
The package contains:
the vacuum suction unit equipped with connection pliers for equipotential circuit and pneumatic
sleeve; the accessories bag containing a dust bag and instruction manuals.

Parts of machine
1 – Suction pipe union
2 – Abrasive holder shelf
3 – Tool support
4 – Dust bin
5 – Vacuum head
6 – Ignition valve
7 – Grounding pliers
8- Suction cleaner frame
9 – hose supports
10 – compressed air supply
11- pneumatic tool plug
12 – fixed wheels
13 – castor wheels
14- technical specification and ATEX marking label

Installation of machine
Place the machine on a stable and level surface. Verify that it is possible to connect the metal
suction cleaner pliers to the grounding system of the working area.
Connect the suction cleaner to the pneumatic sleeve supplied (see figure 1) with the machine and
connect:

-

The quick coupling to the pneumatic sleeve on the front right side of the suction cleaner

-

The suction head to the pipe union of the suction cleaner

Disconnect the supply pipe from the vacuum head using the quick fitting, then remove the vacuum
head using the two metal hooks (see figure 2).
Place the dust bag inside the drum and firmly fix it to the sleeve (see figure 3).
Place the vacuum head in the correct position above the drum and fix it using the metal hooks
supplied.
Connect the supply pipe to the vacuum head (see figure 4).

Connection to the pneumatic supply
Please note: use filtered and dry air only.
Verify that the supply faucet of the suction cleaner is closed.
Connect the supply faucet to a pipe with an internal diameter of 10 mm (see figure 5).
Adjust the supply pressure at 7 bar.
Connect the pneumatic tool to the fitting on the sleeve and the suction pipe to the socket on the
pneumatic tool.
WARNING: for a correct operation, the suction cleaner requires an amount of air equivalent to
1000l/min, added to the amount of air required by the connected pneumatic tool. Verify that the
compressed air plant is able to supply the required amount to the machine.

Connection to the grounding system

CAUTION: ALWAYS connect the machine to the grounding system of the plant using the
metal pliers, specifically during the use of the suction cleaner, the emptying of the dust bag
and its replacement.

Connect the metal pliers to a part of the area that is connected to the grounding system of the plant.
(see figure 6)

User manual

Operation
The supply of the pneumatic tool and suction cleaner can be controlled by means of the faucet
situated on the rear of the suction cleaner.
To protect operators, the pneumatic tool should always be started together with the suction cleaner
to avoid the dust produced from forming potentially explosive atmospheres.
Verify that the suction sleeve is correctly connected to the pneumatic tool and suction pipe union.
Always check the conditions of the dust suction sleeve before using the machine.
Turn the faucet to start the vacuum cleaner.
Switch the pneumatic tool on to start working.
At the end of the work, stop the tool, close the faucet to stop the vacuum cleaner and place the tool
on the support provided.
Use the side supports to wind the supply pipe and the suction sleeve at the end of the work.
Place the abrasives, work tools, etc. on the rear shelf.

Содержание KX 135

Страница 1: ... D ENTRETIEN OPERATING AND MAINTENANCE INSTRUCTIONS BEDIENUNGS UND WARTUNGSANLEITUNG KX 135 Aspiratore pneumatico ATEX ATEX Pneumatic suction cleaner Aspirateur Pneumatique ATEX ATEX Mobilier pneumatischer absauger 11 1 4 13 12 2 3 5 7 8 10 6 14 1 2 3 4 5 6 7 ...

Страница 2: ...se in explosive atmospheres Safety control and monitoring devices that contribute to the safety operating of equipment and protective systems All electrical mechanical hydraulic and pneumatic equipment What are the user s obligations With regard to the prevention of explosions and relative protection users are obliged to take suitable technical or organizational measures depending on the type of c...

Страница 3: ...using a tube with an internal diameter of 10 mm During use the vacuum cleaner must always be connected to the grounding system by means of the pliers supplied RUPES spa does not accept liability for any damage direct or indirect caused by the failure to comply with the instructions provided in these manuals The machine must only be used by trained and qualified personnel The machine must be locate...

Страница 4: ... union of the suction cleaner Disconnect the supply pipe from the vacuum head using the quick fitting then remove the vacuum head using the two metal hooks see figure 2 Place the dust bag inside the drum and firmly fix it to the sleeve see figure 3 Place the vacuum head in the correct position above the drum and fix it using the metal hooks supplied Connect the supply pipe to the vacuum head see f...

Страница 5: ...inside the bin Place a new dust bag inside the bin and connect the flange to the suction union pipe Verify that there are no signs of damage or lacerations on the filtering fabric Place the head on the dust bin verifying that it is correctly oriented Fix the head with the two metal hooks Connect the compressed air supply to the head of the suction cleaner using the quick fittings Removing dust res...

Страница 6: ...ribed in Annex X of 94 9 CE directive and by the following special marking described in Annex II 1 0 5 paragraph of the 94 9 CE D CLARATION DE CONFORMIT É É Anné de apposition de la marquéture Nous déclarons sous notre propre responsabilité que l aspirateur pneumatique pour poussières potentiellement explosibles représenté est conforme à les Requises Essentiels de Sécurité des Directives UNI EN 13...

Отзывы: