background image

Rooftop Packaged

5

K

J

L

M

N

XW

Y

I

Bottom

Supply

Return

H

G

F

E

     

Y

E

F

X

W

Bottom

                  

20~30TON                                                              25, 30TON(Heat Pump)

DIMENSION

(mm)

3,4Ton

5Ton

8,10Ton

13,15Ton 20,25,30Ton

25Ton

(Heat Pump)

30Ton(Heat 

Pump)

E

400

400

443

443

1143

26

26

F

87

87

110

117

660

945

945

G

130

130

219

230

150

/

/

H

300

300

430

430

765

/

/

I

260

260

275

360

73

/

/

J

82

82

98

127

525

/

/

K

48

48

95

150

100

/

/

L

475

475

815

900

290

/

/

M

87

87

113

87

1500

/

/

N

50

50

50

50

55

/

/

W

312

312

215

152

1300

430

430

X

720

720

1570

1900

970

873

873

Y

1010

1010

1394

1564

2068

2068

2068

Z

16

16

14

14

14

14

14

Note: Above diagrams may be different from actual mode

Содержание GK-C03NC1AD

Страница 1: ...ooftop Packaged Commercial Air Conditioners Owner s Manual Thank you for choosing Commercial Air Conditioners please read this owner s manual carefully before operation and retain it for future reference ...

Страница 2: ......

Страница 3: ...oling capacity product number and delivery date Malfunction Describe the actual condition before and after the error happens in details 4 Every unit has passed through strictly test and trial run before delivery In the event of damage to the unit due to improper disassembly user is not allowed to dismantle and check the unit by themselves Please contact local dealer then RUNWAY professional servic...

Страница 4: ...n 3 4 2 General Information 6 4 3 Location 7 4 4 Crane Way 7 4 5 Installation Positions and Clearances 8 4 6 Ductwork 11 4 7 Installation of Condensate Pipe 12 4 8 Adjust the Tightness of the Belt Only above 5 Ton 12 5 Electrical Installation 14 5 1 Electrical Date and Wire Sizing 14 5 2 Connect Wiring to the Terminals 15 5 3 Electrical Connections supply Voltage 16 5 4 Wiring Diagram 17 6 Trial R...

Страница 5: ...losive poisonous or other dangerous substances beside the air conditioner 7 In case of trouble e g burnt smell please immediately cut off the main power of air conditioner unit Caution 1 Before installation please check the power supply for compliance with the ratings on nameplate Check the power safety as well 2 Before use please check and confirm if the drainage pipes and cables are correctly co...

Страница 6: ...oor Conditon Indoor Condition DB Temperatrue C WB Temperatrue C DB Temperatrue C WB Temperatrue C Cooling 35 24 27 19 Heating 7 6 20 15 2 2 Operating Range Item Outdoor Condition DB C Cooling 21 52 Heating 7 24 3 Pre installation Instruction 3 1 Checking Product Received Upon receiving the product check any damage from transportation Shipping damage is the responsibility of the carrier Verify the ...

Страница 7: ... Parts When reporting shortages or damages or ordering repair parts give the complete product model and serial numbers as stamped on the product Replacement parts for this product are available through your contractor or local distributor 4 Installation Instructions 4 1 Physical Dimension B C A D 3 5TON 8 15TON B C A D A B C D 20 30TON 25 30TON Heat Pump DIMENSION mm 3 4Ton 5Ton 8 10Ton 13 15Ton 2...

Страница 8: ...3 4Ton 5Ton 8 10Ton 13 15Ton 20 25 30Ton 25Ton Heat Pump 30Ton Heat Pump O 73 73 203 208 1083 1219 1219 P 400 400 460 460 765 650 650 Q 260 260 275 360 525 525 525 R 75 75 122 120 92 90 90 S 300 300 443 443 660 800 1000 T 105 105 165 165 150 145 145 U 475 475 815 900 1130 1334 1842 V 104 104 175 170 150 145 145 Supply Return Bottom F E Return XW Y Supply Bottom N KL M J IH G 3 5TON 8 15TON ...

Страница 9: ... E 400 400 443 443 1143 26 26 F 87 87 110 117 660 945 945 G 130 130 219 230 150 H 300 300 430 430 765 I 260 260 275 360 73 J 82 82 98 127 525 K 48 48 95 150 100 L 475 475 815 900 290 M 87 87 113 87 1500 N 50 50 50 50 55 W 312 312 215 152 1300 430 430 X 720 720 1570 1900 970 873 873 Y 1010 1010 1394 1564 2068 2068 2068 Z 16 16 14 14 14 14 14 Note Above diagrams may be different from actual mode ...

Страница 10: ...h 50Hz R22 GK H08TC1AM Heat Pump T3 380 415V 3Ph 50Hz 10 R22 GK C10TC1AF Cooling Only T3 220V 3Ph 60Hz R22 GK C10TC1AM Cooling Only T3 380 415V 3Ph 50Hz R22 GK H10TC1AM Heat Pump T3 380 415V 3Ph 50Hz 13 R22 GK C13TC1AF Cooling Only T3 220V 3Ph 60Hz 15 R22 GK C15TC1AF Cooling Only T3 220V 3Ph 60Hz R22 GK C15TC1AM Cooling Only T3 380 415V 3Ph 50Hz R22 GK H15TC1AM Heat Pump T3 380 415V 3Ph 50Hz 20 R2...

Страница 11: ...trong enough to support the weight of unit and it shall be able to insulate noise and prevent vibration Ensure that the wind and noise from the unit will not affect your neighbors 4 Avoid direct sunshine over the unit It is better to set up a sun shield as the protection 5 Place of installation must be able to drain the rainwater and defrosting water 6 Place of installation must ensure the unit wi...

Страница 12: ...ION REAR DUCT MODEL 1 TYPICAL SLAB ON GROUND INSTALLATION Supply Air Duct Return Air Duct Clearance C Clearance B Clearance D Clearance A Clearance E Electric Box MODEL 2 TYPICAL ROOF CURB INSTALLA Clearance J Clearance G Clearance H Clearance I Clearance F Supply AirD uct Return Air Duct Note Above diagrams may be different from actual model ...

Страница 13: ...G 860 34 C 860 34 H 860 34 D 1100 43 I 1100 43 E 1100 43 J 1100 43 MODEL 1 TYPICAL SLAB ON GROUND INSTALLATION Clearance B Clearance E Clearance C Clearance D Clearance A Supply Air Duct Return Air Duct Electric Box MODEL 2 TYPICAL ROOF CURB INSTALLATION Return Air Duct Supply Air Duct Clearance H Clearance G Clearance J Clearance F Clearance I Note Above diagrams may be different from actual mode...

Страница 14: ... G 860 34 C 1100 43 H 1100 43 D 1100 43 I 1100 43 E 1829 72 J 1829 72 MODEL 1 TYPICAL SLAB ON GROUND INSTALLATION Supply Air Duct Return Air Duct Clearance A Clearance E Clearance D Clearance C Clearance B Electric Box MODEL 2 TYPICAL ROOF CURB INSTALLATION Clearance H Supply Air Duct Return Air Duct Clearance I Clearance F Clearance J Clearance G Note Above diagrams may be different from actual m...

Страница 15: ...f 15 Ton or lower As for all other units the side supply air outlet is factory defaulted Meanwhile the button supply air outlet is reserved however the seal plate should be prepared by the user Cover for Air Return Cover for Air Supply Caution 1 The design and installation of air ducts must be in conformity with the relevant state engineering criteria 2 Ductwork is to be constructed in a manner th...

Страница 16: ...pipe shall be installed with an inclining angel of 5 10 so as to facilitate the drainage of condensate 4 As the inside of the unit is in the negative pressure status it is required to set up a backwater elbow The requirements is A B P 10 20 mm P is the absolute pressure inside the unit The unit of the pressure is Pa 5 After the electrical installation is completed carry out the testing of the drai...

Страница 17: ...length of the belt mm Deviation length mm Tension N Min Max SPA 90 200 1582 8 93 18 26 106 190 1582 8 89 18 26 125 190 1632 9 07 18 26 132 180 1632 9 12 15 21 125 170 1632 9 33 18 26 150 170 1632 9 03 21 32 106 180 1432 7 82 18 26 112 180 1432 7 75 15 21 95 190 1432 7 80 18 26 106 190 1432 7 68 18 26 106 170 1432 7 95 18 26 125 170 1582 9 33 18 26 Nut 1 Nut 2 Setting lever Tensiometer Note Above d...

Страница 18: ...6 25 GK C08TC1AM 380 415V 3Ph 50Hz 40 10 10 GK H08TC1AM 380 415V 3Ph 50Hz 40 10 10 GK C10TC1AF 220V 3Ph 60Hz 63 16 25 GK C10TC1AM 380 415V 3Ph 50Hz 40 10 10 GK C10TC1AM 380 415V 3Ph 50Hz 100 25 50 GK H10TC1AM 380 415V 3Ph 50Hz 40 10 10 GK C13TC1AF 220V 3Ph 60Hz 100 25 50 GK C15TC1AF 220V 3Ph 60Hz 100 25 50 GK C15TC1AM 380 415V 3Ph 50Hz 63 16 25 GK C15TC1AM 380 415V 3Ph 50Hz 110 25 50 GK H15TC1AM 3...

Страница 19: ...erminal Strand wire Solid wire Insulation 10 25 Warning If the power line or the signal line is defective use the special coil to replace it 1 Before connecting lines read the voltages of the relevant parts on the nameplate Then carry out line connection according to the schematic diagram 2 The air conditioning unit shall have special power supply line which shall be equipped with electricity leak...

Страница 20: ...upply cable to terminals and the grounding screw according to wiring diagram Use cable fastener to bundle and fix the cable 3 Low Voltage Connections Low voltage wiring is to be copper conductors A minimum of 18AWG must be used for installations up to 50 and 16AWG for installations over 50 Remove the Electric Box Cover of the unit Pass the signal cable of the wire controller though rubber ring Con...

Страница 21: ...ND Electric Box POWER 220V 60Hz THERMOSTAT L1 L1 L2 L2 R R C C Y1 Y1 Single Phase 220V 50Hz POWER SUPPLY Model GK C03TC1AK Electric Box N L N L R C Y1 R C Y1 GROUND POWER 220V 50Hz THERMOSTAT Three Phase 220V 3 60Hz POWER SUPPLY Model GK C04TC1AF GK C05NC1AF GK C05TC1AF GROUND Electric Box POWER 220V 3 60Hz THERMOSTAT L1 L2 L3 N L1 L2 L3 R C Y1 R C Y1 ...

Страница 22: ... Y1 G Y2 O R C Y1 G Y2 O Three Phase 380 415V 3N 50Hz POWER SUPPLY Model GK C04TC1AM GK C05TC1AM Electric Box GROUND THERMOSTAT POWER 380 415V 3N 50Hz L1 L2 L3 N L1 L2 L3 N R C Y1 R C Y1 Model GK C08TC1AM GK C10TC1AM GK C15TC1AM GK C20TC1AM GK C25TC1AM THERMOSTAT Electric Box GROUND L1 L2 L3 N L1 L2 L3 N POWER 380 415V 3N 50Hz R C Y1 G W1 W2 Y2 O B R C Y1 G W1 W2 Y2 O B ...

Страница 23: ...Y1 G W1 W2 Y2 O B 5 4 2 Heat Pump Three Phase 380 415V 3N 50Hz POWER SUPPLY Model GK H05TC1AM Electric Box GROUND THERMOSTAT POWER 380 415V 3N 50Hz L1 L2 L3 N L1 L2 L3 N R C Y1 O R C Y1 O G B Model GK H08TC1AM GK H10TC1AM GK H15TC1AM GK H20TC1AM GK H25TH1AM GK H30TH1AM Electric Box GROUND THERMOSTAT POWER 380 415V 3N 50Hz L1 L2 L3 N L1 L2 L3 N R C Y1 Y2 G O R C Y1 Y2 G O B ...

Страница 24: ...ic heat units GK C10TC1AM GK C13TC1AF GK C15TC1AM GK C20TC1AM GK C25TC1AF GK C25TC1AM GK C30TC1AM TERMINAL FUNCTION R power supply for the wired controller C power supply for the wired controller Y1 Y2 start the compressor and outdoor condensing side fan motor G start the indoor evaporating side fan motor W1 startup electrical heater W2 startup electrical heater Caution When it is cooling operatio...

Страница 25: ...d The power supply does not connect or improper phase sequence Connect the power supply or change two random phase Electrical leakage of air conditioning unit causes tripping of leakage switch Contact the nearest service center The voltage is too low Contact the dealer The control loop has failure Contact the nearest service center The unit operates for a while and then stops Air outlet port or in...

Страница 26: ... regularly at least once every two months You can clean the surface with vacuum cleaner or nylon brush please do not wash it with water 3 Belt The indoor units are driven by belt You should check the tightness of the belt after operating for a period of time only above 5 ton 4 Maintenance at the Beginning of Operating Season Check the air inlet and outlet of the units to confirm there is no blocka...

Страница 27: ......

Страница 28: ......

Отзывы: