Preparation for Installation 

Precautions 

The wireless controller acts as a network repeater and its working affects the normal operation of the whole network. 

T

he following suggestions are advised for the installation and use of RG-WS6108: 

 

Do not place the wireless controller in a damp/wet location. Do not let any liquid enter the chassis. 

 

Keep the wireless controller far away from the heat source. 

 

Ensure that the wireless controller is properly grounded. 

 

Wear an anti-static wrist strap during installation and maintenance. 

 

Do not wear loose clothes to avoid hooking any parts. Before operation, tighten your band, shawl, and sleeves. 

 

Put the tools and parts away from where people walk by. 

 

Use UPS to prevent power failure and other interferences. 

 

If the clock is not accurate, check whether the clock has been configured. If not, the inaccuracy is likely to occur. If 

the clock has been configured, the inaccuracy may be caused by the battery running out of power. In general, the 

button battery lasts about 10 years.   

 

Misuse of battery may cause damage to the device or hurt to people. Do not replace battery by yourself. Instead, 

contact Ruijie Service Center for the replacement of battery.   

 

This device is an A-class product. It may cause radio interference in living environment, which may require you to 

take anti-interference measures.   

 

Keep the device within the restricted-access area. 

 

The device should be installed by professionals or technicians.   

Preparing Installation Site 

RG-WS6108 is for indoor use only. To ensure its normal operation and prolong its life span, the installation site should 

meet the following requirement: 

Temperature and Humidity Requirements 

To ensure normal operation and service life of the device, maintain appropriate temperature and humidity levels in your 

equipment room. See Table 2-1. Improper room temperature and humidity can cause damages to the device. High 

relative humidity may affect insulation materials, resulting in poor insulation and even electrical leakage, and sometimes 

may lead to change of mechanical properties of materials and corrosion of metal parts. Low relative humidity may dry and 

shrink insulation sheets and cause static electricity that can damage the circuitry inside the device. High temperature 

greatly reduces reliability of the device and shortens its service life. 

Table 2-1 Required Temperature and Humidity for the RG-WS6108 

Содержание RG-WS6108 Series

Страница 1: ...RG WS6108 Series Wireless Controller Hardware Installation and Reference Guide V1 01...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...Website https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical...

Страница 4: ...Configuration port Console port RS 232 Dimensions W x D x H 440 mm x 200 mm x 43 6 mm excluding foot pad Voltage 100 240V 50 60Hz Power Consumption 40W max Operating Temperature 0 C to 45 C 32 to 113...

Страница 5: ...system sends out an alarm 1 8 Gigabit copper ports link ACT Solid green The copper port is connected at 10 100 1000 Mbps Blinking green The copper port is receiving or transmitting data 1 8 Gigabit co...

Страница 6: ...e battery by yourself Instead contact Ruijie Service Center for the replacement of battery This device is an A class product It may cause radio interference in living environment which may require you...

Страница 7: ...ervice life of the device and cause communication failures Table 0 2 shows the maximum concentration and diameter of dust allowed in the equipment room Table 2 2 Maximum Diameter m 0 5 1 3 5 Maximum C...

Страница 8: ...ion Site Requirements To install the wireless controller whether in the cabinet or on the workbench pay attention to the following items Ensure that enough space is reserved around the air inlet and e...

Страница 9: ...controller is ready for installation Mount it to either of these two places A cabinet A workbench Mounting RG WS6108 in Cabinet RG WS6108 is designed according to the specification of 19 inch standar...

Страница 10: ...wire power socket or multi functional microcomputer socket with neutral point connector The neutral point needs to be grounded safely Check whether the power supply in your building is grounded proper...

Страница 11: ...console port of the wireless controller and the other end to the DB 9 male serial adapter of the microcomputer Verification When you have installed the wireless controller before powering on it pay at...

Страница 12: ...ter you will need to run a terminal emulation program like Windows operating system s Hyperterm Take Hyperterm for example 1 Run Hyperterm and create a connection 2 Select the serial port to be connec...

Страница 13: ...rs for Serial Port After building the configuration environment you may power on the wireless controller Powering on Wireless Controller Verification Before Power on Before powering on the wireless co...

Страница 14: ...will feel the air flowing If the indicators on the front panel of the wireless controller are in the proper state See LED Indicators in Chapter 1 If the configuration terminal displays information as...

Страница 15: ...uch device or address Starting rg_lowmem_killer OK Starting snooping elf OK Starting postgresql server mnt sata0 pgsql bin postgres not found OK Starting rg mtdoops cli OK Starting sntp elf OK Press R...

Страница 16: ...ing If the system is operational relevant information is displayed on the terminal as described in chapter 4 Otherwise nothing or gibberish is displayed If nothing is displayed please check the follow...

Отзывы: