Содержание RG-S7800 Series

Страница 1: ...Hardware Installation Guide RG S7800 Series High density Multi service IPv6 Core Routing Switch...

Страница 2: ......

Страница 3: ...ten consent of Ruijie Networks is prohibited are registered trademarks of Ruijie Networks Counterfeit is strictly prohibited Exemption statement This document is provided as is The contents of this do...

Страница 4: ......

Страница 5: ...et before you install the switch n Chapter 4 Installation describes how to install the switch as a whole and its various modules and connect power supply and grounding cables n Chapter 5 Maintenance a...

Страница 6: ...s provides all customers with needed technical assistance product technology and solutions The customer service center provides responsive technical support for your product installation problems soft...

Страница 7: ...of RG S7800 series and RG S8600 RG S5700 RG S3760 provides users with stable secure and efficient enterprise network solution Figure 1 1 Typical Application for RG S7800 swiches RG S7800 series suppor...

Страница 8: ...Hot swappable Supported Management redundancy Supported Unsupported Power supply Fan Power supply System Power RG PA300I 100 240V 50 60Hz Power 400W Installed PoE Power RG PA300P 100 240V 50 60Hz Pow...

Страница 9: ...the CMs control modules and 4 slots for the service modules This core routing switch supports up to 96 GE interfaces 8 10GE interfaces or 192 FE interfaces line speed forwarding Figure 1 2 shows the...

Страница 10: ...o implement the redundancy management function and the four slots with the number 1 2 3 4 are for different service modules according to the application requirements 2 Total 4 power slots are on the b...

Страница 11: ...al working of the device Table 1 3 lists the technical specification of the M7806 FAN I Specification Parameter M7806 FAN I Card dimension 300 460 30 Lx W x H Fan count 9 Revolutions per minute 4500RP...

Страница 12: ...e night fans is out of work other fans can still address the requirement of the ventilation and heat dissipation of the whole system However the RPM of the all normal fans reaches the maximum limit re...

Страница 13: ...implement the redundancy management function and the three slots with the number 1 2 3 4 are for different service modules according to the application requirements 2 Total 3 power slots are on the b...

Страница 14: ...device Table 1 5 lists the technical specification of the M7804 FAN I Specification Parameter M7804 FAN I Card dimension 200 460 30 Lx W x W Fan count 6 Revolutions per minute 4500RPM Flow measurement...

Страница 15: ...k other fans can still address the requirement of the ventilation and heat dissipation of the whole system However the RPM of the all normal fans reaches the maximum limit resulting in the intelligent...

Страница 16: ...the external PoE power supply 1 5 2 1 Host Power System The RG S7800 host power system locates on the back of the switch and the RG PA300I AC power module is available for the user Table 1 7 lists the...

Страница 17: ...lists the power consumption of each module in the system Table 1 8 Power information for each module Module name Power Module name Power M7800 CM 40W M7800 02XS24SFP 8GT 45W M7806 FAN I 70W M7800 24S...

Страница 18: ...in PoE power module technical specification Power Module RG PA300P AC input voltage range 100 240V 50 60Hz DC input voltage range external PoE power input connected with RG PSE 50 57V Output voltage...

Страница 19: ...e max power of the external PoE power module 1 5 2 2 2 External PoE Power RG S7800 s external PoE power system locates on the RG PSE module providing 2 slots for the power supply and one slot for the...

Страница 20: ...ailed Information RUN System LED OFF The module has not been powered on or the input power fault Green The input power works normally ALARM Alarm LED OFF The module works normally Solid Yellow Recover...

Страница 21: ...ordance with only one RG PA800 PSE inserted Warning 1 All RG PSE modules and the monitoring module must be pulled out from the chassis before moving or transporting the RG PSE chassis Moving or transp...

Страница 22: ...cates on the left of the chassis The air filter is used to prevent the dust and debris from being blown to the switch frame to cause the cicuit board damage To this end the air filter must be installe...

Страница 23: ...nterfaces and 10G optic fiber ports ect The following chapters introduces the specifications of each service card modules in detail 2 2 M7800 CM M7800 CM performs the management and switching function...

Страница 24: ...he system running performance yet the system can still be running Link ACT MGMT port LED OFF Port is not linked up Green Port is linked up and the data will be transmitted at the rate of 100Mbps Yello...

Страница 25: ...T Category 5 twisted pairs LED Status Link ACT LED Hot swappability Supported Power consumption 40W EMC GB9254 1998 FCC Class A Safety regulation GB4943 2001 Operating temperature 0 to 50 C Storage te...

Страница 26: ...tted on the port SFP port LED OFF Port is not linked up Green Port is linked up and the data will be transmitted at the rate of 100Mbps Yellow Port is linked up and the data will be transmitted at the...

Страница 27: ...SR 850nm Multi mode optic fiber 10GBASE LR 1310nm Single mode optic fiber 10GBASE ER 1550nm Single mode optic fiber 1000BASE SX 850nm Multi mode optic fiber 1000BASE LX 1310nm Single mode optic fiber...

Страница 28: ...een The module has finished initialization and can perform switching normally Link ACT GT port LED OFF Port is not linked up Green Port is linked up and the data will be transmitted at the rate of 100...

Страница 29: ...005 Port type 48 10 100 1000BASE T copper RJ45 ports Transmission media 10 100 1000BASE T 100m Category 5 twisted pairs LED Status Link ACT LED Hot swappability Supported Power consumption 60W EMC GB9...

Страница 30: ...er management function Upon being inserted into the chassis or powering on the chassis all RG S7800 service cards are not powered on and all LEDs are OFF untill the CMs control over powering on the se...

Страница 31: ...er for the external PSE power module is 1600W up to configure 2 RG PA800 PSE modules You shall select and set the appropriate power modules according to the actual requirements of the PoE power 2 6 2...

Страница 32: ...s the power management function Upon being inserted into the chassis or powering on the chassis all RG S7800 service cards are not powered on and all LEDs are OFF untill the CMs control over powering...

Страница 33: ...following requirement n Avoid moving the equipment frequently n Turn off all power supplies and unplug all power cables before you remove the equipment n At least two people are needed to move the eq...

Страница 34: ...ricity great damage may be caused to the circuitry and equipment when the static electricity exceeds a certain limit In the communication network of the RG S7800 electrostatic induction may come from...

Страница 35: ...firm enough to bear the weight of the RG S7800 and its installation accessories n Be sure that the dimensions of the cabinet is appropriate for installation of the RG S7800 that can reserve a certain...

Страница 36: ...o the running of the equipment The indoor dust falling on the equipment may be adhered by the static electricity causing bad contact of the metallic joint Such electrostatic adherence may occur more e...

Страница 37: ...fety cable ground The lightning discharge ground is for the facility only irrelevant to the equipment 3 3 3 EMC Ground The ground required for EMC design includes shielding ground filter ground noise...

Страница 38: ...ing the fibers you should ensure that the type of optical connector and the type of fibers match the type of the optical interface used Moreover you should pay attention to the Tx and Rx directions of...

Страница 39: ...mentation n Packing list 3 Module carton n Various modules n Packing list n Documentation Note A normal delivery should contain the above mentioned items which may differ from the actual delivery depe...

Страница 40: ...ion Guide Chapter 4 Switch Installation 18 Switch Installation Note 1 Before you install the RG S7800 make sure you have carefully read Chapter 3 and this chapter 2 Be sure that the requirements set f...

Страница 41: ...e following before installation n The installation location is of a good air flow n The installation location meets the temperature and humidity requirements of the equipment n The qualified power sup...

Страница 42: ...s of the equipment should be installed securely and the fastening screws on the panel should be tightened n All wiring inlets at the top and bottom of the cabinet should be installed with rodent resis...

Страница 43: ...e RG S7800 series switch as shown in the figure1 3 and the figure1 6 by loosening the captive screws 2 Insert the power supply module 3 Tighten the screws Warning 1 The configured total power for the...

Страница 44: ...connect the other end to the monitoring module RG PSE M s RS485 s interface 5 Connect one end of the shipped AC power cable to the RG PSE AC power input interface and connect the other end to the moni...

Страница 45: ...g the AC Power Supply to the Power Module Connect AC power cables according to the ID and position instruction on the RG PA300I panel of the AC power module 4 7 1 Precautions n Before connecting the p...

Страница 46: ...into the guide rail 3 Push the card into position by using the ejector and tighten the two captive screws on the card with a cross screwdriver Warning 1 Do not hold the edge of the PCB or collide the...

Страница 47: ...ification on the panel of the linecard Distinguish the crossover cable and straight through cable 4 Connect the cables and fibers of each board in sequence 4 12 Binding the Cables 4 12 1 Precautions n...

Страница 48: ...inet and all the cables have been fastened to the cabinet 4 13 2 Verifying the Cables n Verify that the fibers and twisted pairs match the ports n Verify that the cables have been bound properly 4 13...

Страница 49: ...ns that the power supply is faulty in which case you should replace it promptly The RG S7800 allows you to monitor various system status by executing the appropriate CLI commands including n Module bo...

Страница 50: ...ernet a user can realize communication through remote Telnet login During installation and networking RG S7800 and the Internet are connected therefore the user can log in to the RG S7800 via Telnet a...

Страница 51: ...g after installation Check the cabinet installation Check the mounting of the RG S7800 switch in the cabinet Check the power connection Check the installation of the power module Check the linecards a...

Страница 52: ...e is loose If yes insert the board to another slot for a try If the slot and connection are not the cause return the linecard for repair Fault 4 The LED is abnormal after a linecard works for some tim...

Страница 53: ...800 Software Configuration Guide If not modify the serial port configuration parameters If there is still no serial port printed information please contact Ruijie Customer Service Department for techn...

Страница 54: ...uide 32 the maximum power If so please add more power modules to provide the enough power for the power supply If all checkings are OK but the newly inserted service card module still cannot be powere...

Страница 55: ...which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four twisted pairs of the 1000BASE T Straight Through Crossover Switch Switch 1TP0...

Страница 56: ...TX 10BASE T Figure A 3 Connections of the twisted pairs of the 100BASE TX 10BASE T 2 Fiber Connection For the optic ports select single mode or multiple mode fibers for connection according to the fi...

Страница 57: ...C SFP Module Table B 1 SFP modules and technical specification Mini GBIC SFP Wavele ngth nm Trans missio n Rate bps Media Type Core Size nm Maximu m cabling distance Optical Intensity dBm MAX Receptio...

Страница 58: ...0G SFP Module Table B 2 10G SFP modules and technical specification Model Wavelength nm Media Type Core Size nm Mode Bandwidth MHz km Maximum Cabling Distance Optical Intensity dBm Reception Sensitivi...

Страница 59: ...ow shall be used on the AC power port to prevent the switch from being struck by lightning when the AC power cable is introduced from the outdoor and directly connected to the power port of the switch...

Страница 60: ...nstalling the Ethernet Port Arrester During the switch usage the Ethernet port arrester shall be connected to the switch to prevent the switch damage by lightning before the outdoor network cable conn...

Страница 61: ...e refer to Ethenet Port Arrester Hardware Installation Guide which contains the technical specification and the maintenance and installation of the arrester 2 3 Installation Tips You may pay attention...

Страница 62: ...Appendix S7800 Series Hardware Installation Guide iv on the switch it needs to install the arresters on all connection ports for the purpose of the lightning protection...

Отзывы: