background image

Chapter 1 Product Overview 

1.1 Product Overview 

The RG-S2924GT/8SFP-XS-P switches of Ruijie are high-performance, high-security and multi-service L2 
switches, mostly applied at the aggregation or access layers of large-sized networks to provide line-speed 
exchanging and complete QoS services, and ensure the undelayed transmission of key data by applying different 
traffic classification rules to different services. The 

RG-S2924GT/8SFP-XS-P provide flexible medium interfaces 

and can meet the connection requirements of different media in network constructions. 

Table 1-1 RG-S2924GT/8SFP-XS-P 

Model 

10/100/1000Base-T 
adaptive Ethernet 
port 

1000Base-X SFP 
port 

Console port  Extension 

Module Slot

Redundancy 
Power 

RG-S2924GT/8SFP-XS-P 24 

8(Combo) 

Dual 

power 

The extension module slot supports M5000E-02SFP/GT, M5000E-01XS and M5000E-02XS modules. Table1-2 lists 
the supported extension modules. 

Table 1-2 Supported Extension Modules 

Model 

1000Base-X SFP port 

10/100/1000Base-T adaptive Ethernet port 

M5000E-02SFP/GT 

2-port 1000M fiber/copper combo 
module 

2 10/100/1000Base-T adaptive Ethernet ports 

2 Combo 1000Base-X SFP ports

 

M5000E-01XS 

1-port 10G interface module 

1 SFP port 

M5000E-02XS 

2-port 10G interface module 

2 SFP ports 

The 1000 Base-X SFP port and the corresponding 10/100/1000Base-T adaptive Ethernet port form one fiber/copper 
combo port, i.e., only one of the ports that form the fiber/copper combo port at the same time can be used.   

For the detailed information about the supported modules, please refer to 

Switch Extension Module Usage Guid

e.  

1.2 Main Technical Specifications of RG-S2924GT/8SFP-XS-P 

Table 1-3 Technical specifications of the RG-S2924GT/8SFP-XS-P   

Switch Model 

RG-S2924GT/8SFP-XS-P 

Содержание RG-S2924GT/8SFP-XS-P

Страница 1: ...Installation Manual RG S2924GT 8SFP XS P...

Страница 2: ...ans are all registered trademarks of Ruijie Networks Ltd and are protected by law Disclaimer The information contained in this manual may be modified without notification Ruijie Networks has tried its...

Страница 3: ...16 2 3 1 Safety Grounding 16 2 3 2 Lightning Grounding 16 2 3 3 EMC Grounding 16 2 4 Lightning Resistance Considerations 16 2 5 EMI Consideration 17 2 6 Precaution for Fiber Connections 17 2 7 Precaut...

Страница 4: ...2 1 Checking before Power on 23 4 2 2 Checking after Power on Recommended 24 Chapter 5 Maintenance and Troubleshooting 25 5 1 General Troubleshooting Procedure 25 5 2 Troubleshooting Common Faults 25...

Страница 5: ...ns in the switch installation and application Appendix A Connector and Connection Media Appendix B Mini GBIC Modules Related Documents Software manual of switches covering CLI commands software config...

Страница 6: ...Conventions The symbols used in this document are described as below This symbol draws the attention of readers to some suggestions and references This symbol reminds readers to be alert of wrong ope...

Страница 7: ...wer The extension module slot supports M5000E 02SFP GT M5000E 01XS and M5000E 02XS modules Table1 2 lists the supported extension modules Table 1 2 Supported Extension Modules Model 1000Base X SFP por...

Страница 8: ...type Dual power Power supply AC input Rated voltage range 100 240V Maximum voltage range 90 264V Frequency 50 60Hz Rated current 6A POE Supported on all RJ45 ports up to 30W power supported on each po...

Страница 9: ...XS P Ethernet switch provides twenty four 10 100 1000Base T Ethernet ports eight GE SFP fiber copper combo ports and one Console port The backplanel provides two power module slots and two extension m...

Страница 10: ...module chapter Dual power input The switch power can be supplied by 1 power module or by 2 power modules When both two modules are available the switch power is supplied by the redundant power input W...

Страница 11: ...reen The switch is being initialized If the blinking persists however it indicates that an abnormality occurs Solid green Normal switching is performed by the switch Solid yellow It indicates a warnin...

Страница 12: ...o is Up Blinking green Data at a rate of 1000 M are being transceived at the port Solid yellow The 100 M link that the port connects to is Up Blinking yellow Data at a rate of 100 M are being transcei...

Страница 13: ...off all power supplies and dismantle all power modules 2 1 3 Electric Safety Observe local regulations and specifications when performing electric operations Relevant operators must be qualified Care...

Страница 14: ...penings to ensure the normal ventilation After various cables have been connected they should be arranged into bundles or placed on the cabling rack to avoid blocking the air inlets 2 2 2 Temperature...

Страница 15: ...e intrusion of harmful gases such as sulfur dioxide sulfured hydrogen nitrogen dioxide and chlorine whose requirements are listed in Table 2 3 Table 2 3 Requirements for harmful gases in the equipment...

Страница 16: ...shares the power reference ground and yellow green safety cable ground The lightning discharge ground is for the facility only irrelevant to the equipment 2 3 3 EMC Grounding The grounding required fo...

Страница 17: ...rference may affect any signal path in the equipment and is difficult to shield 1 Effective measures should be taken for the power system to prevent the interference from the electric grid 2 The worki...

Страница 18: ...The power module is hot swappable It s recommended to disable all power switches when plugging in out the power module and enable the switch with the power module inserted and installed...

Страница 19: ...tools Common tools Cross screwdriver straight screwdriver related electric cables and optical cables bolts diagonal pliers straps Special tools Anti static tools Meters Multimeter The RG S2924GT 8SFP...

Страница 20: ...Confirmations before Installation Before installation please confirm the following points Whether sufficient airflow is available for the switch Whether the requirements of the switch for temperature...

Страница 21: ...elding should be adopted For example use interface cables to shield cables Interface cables should be laid inside the equipment room Outdoor cabling is prohibited avoiding damages to device signal int...

Страница 22: ...around the switch can flow freely 3 4 Checking after Installation Before checking the installation switch off the power supply so as to avoid any personal injury or damage to the component due to con...

Страница 23: ...PC Step 2 Connect one end of the console cable RJ45 to the console port of the switch 4 1 3 Setting Terminal Parameters Step 1 Start the PC and run the terminal simulation program on the PC such as Te...

Страница 24: ...the parameters are already configured 4 2 2 Checking after Power on Recommended After power on you are recommended to perform the following checks to ensure the normal operation of follow up configura...

Страница 25: ...tatus indicator is not on after the switch is started The power supply module does not supply power The power cable is in loose contact Check whether the power socket at the equipment room is normal a...

Страница 26: ...cted switch The fiber port cannot be connected The Rx and Tx ends are connected reversely The interconnected optical module type does not match The fiber type is not correct The length of the optical...

Страница 27: ...hematic diagram for the four twisted pairs of the 1000BASE T Straight Through Crossover Switch Switch 1TP0 1TP0 2TP0 2TP0 3TP1 3TP1 6TP1 6TP1 4TP2 4TP2 5TP2 5TP2 7TP3 7TP3 8TP3 8TP3 Switch Switch 1TP0...

Страница 28: ...orts select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4 Schematic diagram for...

Страница 29: ...M1310 1310 Multi mode optical fiber 62 5 125 N A 2km 14 14 IEEE802 3 FE SFP LH15 SM1310 1310 Single mod e optical fiber 9 125 N A 15km 8 8 Mini GBIC SX 850 Multi mode optical fiber 62 5 62 5 50 0 50...