Ruijie RG-NBS3100 Series Switches Hardware Installation and Reference Guide 

 

Preparation before Installation 

 

21 

 

The equipment using AC power supply must be grounded by using the yellow/green safety grounding cable. Otherwise, 

when  the  insulating  resistance  decreases  the  power  supply  and  the  enclosure  in  the  equipment,  electric  shock  may 

occur. 

 

The building must provide protective grounding connection to ensure that the device is connected to the protection 

location. 

 

The  installation  and  maintenance  personnel  must  check  whether  the  A.C.  socket  is  well  connected  to  the 

protection location of the building, if not, they should use a protective grounding wire to connect the grounding end 

of the A.C. socket to the building's protection location. 

 

The power supply socket must be installed in a place that is near to the device and where users can operate the 

device easily. 

 

Before  the  installation  of  the  device,  make  sure  that  ground  connection  is  connected  at  first  and  disconnected 

finally. 

 

The sectional area of the protective grounding wire should be at least 0.75 mm

2

 (18 AWG). 

 

Use the 3-core power supply line. The sectional area of each pin should be at least 0.75 mm

2

 or 18 AWG. 

Lightning Grounding 

The  lightning  protection  system  of  a  facility  is  an  independent  system  that  consists  of  the  lightning  rod,  download 

conductor  and  the  connector  to  the  grounding  system,  which  usually  shares  the  power  reference  ground  and 

yellow/green safety cable ground. The lightning discharge ground is for the facility only, irrelevant to the equipment. 

EMC Grounding 

The grounding required for EMC design includes shielding ground, filter ground, noise and interference suppression, 

and level reference. All the above constitute the comprehensive grounding requirements. The resistance of earth wires 

should be less than 1 ohm. The RG-NBS3100 series switch back plane is reserved with one grounding pole, as shown 

in Figure 2-1. 

Figure 2-1 Grounding of RG-NBS3100 

 

2.2.6  Lightning Resistance 

When the AC power cable is imported outdoors and directly connected to the power port of the RG-NBS3100 series 

switch,  lightning  line  bank  should  be  adopted  to  prevent  the  switch  from  being  hit  by  lightning  shocks.  Usage  of  the 

lightning  line  bank:  Connect  the  mains  supply  AC  cable  to  the  lightning  line  bank.  Then,  connect  the  switch  to  the 

lightning line bank. This can help to prevent the current of high-voltage lightning from passing the switch directly through 

the mains supply cable to a certain extent. 

 

The lightning line banks are not provided and should be purchased by users as required. 

For the usage of lightning line banks, refer to their related manuals. 

Содержание RG-NBS3100 Series

Страница 1: ...Ruijie RG NBS3100 Series Switches Hardware Installation and Reference Guide...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...ite https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical Suppo...

Страница 4: ...wnward compatible with 100Base FX 1000Base T is downward compatible with 100Base TX and 10Base T 1 1 RG NBS3100 24GT4SFP Technical Specifications Model RG NBS3100 24GT4SFP CPU Built in CPU single core...

Страница 5: ...61000 3 3 EN 55035 ETSI EN 300 386 Security Standards GB4943 2011 EN 62368 1 Dimensions W x D x H 440 mm x 165 mm x 44 mm Weight 2 4 kg The RG NBS3100 24GT4SFP switch is a class A product In a domest...

Страница 6: ...the separate protective earthing terminal The device installation shall be permanently connected to building earth by a skilled person The device shall be intended to be used in a location having equ...

Страница 7: ...cal Specifications Model RG NBS3100 24GT4SFP P CPU Built in CPU single core processor 500MHz Flash Memory 16 MB SDRAM DDRIII 256MB Optical Module See Appendix B The copper cable is not supported The s...

Страница 8: ...RG NBS3100 24GT4SFP P switch is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures The high tempera...

Страница 9: ...he LED is solid green it indicates that the PoE supported ports are supplying power when the LED blinks green the power of the ports is overloaded Back Panel Figure 1 6 Back Panel of RG NBS3100 24GT4S...

Страница 10: ...f The port is not connected Solid green The port is connected at 10 100 1000 Mbps Blinking green The port is receiving or transmitting traffic at 10 100 1000 Mbps RJ45 port PoE status LED 1 24 Off PoE...

Страница 11: ...d Power Consumption 8W Temperature Operating temperature 0 C to 50 C Storage temperature 40 C to 70 C Humidity Operating humidity 10 to 90 RH Storage humidity 5 to 95 RH Fan Not supported Temperature...

Страница 12: ...00 8GT2SFP Front Panel Figure 1 9 Front Panel of RG NBS3100 8GT2SFP Note 1 System status LED 2 Reset button 3 10 100 1000 Base T Ethernet port 4 Copper port status LED 5 1000 Base X SFP port 6 SFP por...

Страница 13: ...air circulation It is recommended to clean the device once every 3 months to avoid dust from blocking vents LED LED Panel Identification State Meaning System status LED Status Off The switch is not re...

Страница 14: ...PoE Supports PoE and PoE Ports 1 8 are PoE capable with the maximum power output of 30W per port Port 9 does not support PoE The overall maximum output power of PoE PoE is 125W PoE Mode Mode A data pa...

Страница 15: ...d be installed in the restricted area when the ambient temperature exceeds 50 deg C Product Appearance On the front panel the RG NBS3100 8GT2SFP P Ethernet switch provides 8 10 100 1000Base T Ethernet...

Страница 16: ...a skilled person The device shall be intended to be used in a location having equipotential bonding such as a telecommunication centre a dedicated computer room or a restricted access area Heat Dissi...

Страница 17: ...lation Keep the chassis clean and free from dust Do not place the equipment in a passage Do not wear loose clothes or any other things that may be caught by the chassis during installation and mainten...

Страница 18: ...eakage protector divided by two is greater than the sum of maximum leakage currents of all the power supplies The rated leakage non action current of a leakage protector shall be 50 of the leakage act...

Страница 19: ...the equipment may be damaged In an environment with high relative humidity the insulating material may have bad insulation or even leak electricity Sometimes the materials may suffer from mechanical...

Страница 20: ...caused by capacity coupling inductance coupling electromagnetic wave radiation common impedance including grounding system coupling and conducting wires including power cords signal and output wires T...

Страница 21: ...tection system of a facility is an independent system that consists of the lightning rod download conductor and the connector to the grounding system which usually shares the power reference ground an...

Страница 22: ...er Radiated interference may affect any signal path in the equipment and is difficult to shield For the AC power supply system TN single phase three core power socket with protective earthing conducto...

Страница 23: ...re installation please confirm the following points Whether ventilation requirements are met for the switch Whether the requirements of temperature and humidity are met for the switch Whether power ca...

Страница 24: ...pted For example use interface cables to shield cables 100 meter network cables should be laid inside the equipment room and outdoor cabling of such cables is prohibited If outdoor cabling is necessar...

Страница 25: ...Port Switch Figure 3 5 Attaching the Brackets to the Rack 24 Port Switch Figure 3 6 Attaching the Brackets to the Rack 24 Port Switch 3 3 2 Mounting the Switch on a Table Attach the four rubber pads...

Страница 26: ...aximum current Cables of good conductor should be used Do not use bare wire The grounding electric resistance should be less than 1 To guarantee the security of the body and the device the switch must...

Страница 27: ...fibers at the connectors have natural bends or bends of large radius Do not bundle fibers and twisted pairs too tightly as this may press hard the fibers and affect their service time and transmission...

Страница 28: ...Ruijie RG NBS3100 Series Switches Hardware Installation and Reference Guide Product Installation 28 Check that sufficient airflow is available around the device over 10 cm...

Страница 29: ...d RJ 45 port of the network cable to any Ethernet port of the switch Configuring the Device Step 1 Start the PC and configure the IP address of the PC as 10 44 77 XXX 10 44 77 XXX indicates the IP add...

Страница 30: ...the parameters are already configured Checking after Power on Recommended After power on you are recommended to perform the following checks to ensure the normal operation of follow up configurations...

Страница 31: ...port is not in connectivity or it is erroneous in receiving transmitting frames The connected twisted pair cable is faulty The length of the cable exceeds 100 m The port has special configuration tha...

Страница 32: ...Ruijie RG NBS3100 Series Switches Hardware Installation and Reference Guide Troubleshooting 32 that rated of the optical module appropriate length...

Страница 33: ...BASE T port uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Schematic Diagram for...

Страница 34: ...and Connection Media 34 Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection s...

Страница 35: ...ransmitted Light dBm Intensity of Received Light dBm Min Max Min Max MINI GBIC SX MM8 50 850 MMF No 9 5 3 17 0 MINI GBIC LX SM13 10 1310 SMF No 9 5 3 20 3 GE eSFP SX MM85 0 850 MMF Yes 9 5 3 17 0 GE e...

Страница 36: ...MF 50 125 500m GE SFP SX SM1550 BIDI LC MMF 50 125 500m GE SFP LX20 SM1310 BIDI LC SMF 9 125 20km GE SFP LX20 SM1550 BIDI LC SMF 9 125 20km GE SFP LH40 SM1310 BIDI LC SMF 9 125 40km GE SFP LH40 SM1550...

Страница 37: ...Module 37 Rate Distance Module Pairs 1000M 500m GE SFP SX SM1310 BIDI GE SFP SX SM1550 BIDI 1000M 20km GE SFP LX20 SM1310 BIDI GE SFP LX20 SM1550 BIDI 1000M 40km GE SFP LH40 SM1310 BIDI GE SFP LH40 SM...

Страница 38: ...cal requirement Precautions for installation Make sure that the PE terminal of the power arrester has been well grounded After connecting the switch AC power plug to the socket of the power arrester l...

Страница 39: ...to check whether the grounding line for the arrester is in good contact with the switch grounding terminal and the framework According to the description on the Ethernet Port Arrester Hardware Instal...

Страница 40: ...to the OUT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal Use the multimeter to con...

Страница 41: ...erall diameter The minimum bend radius of a coaxial cable should be 7 times the overall diameter of the cable If the cable is constantly bent plugged or unplugged the bend radius should be 10 times th...

Страница 42: ...proper cable ties to bind cables together Do not tie two or more cable ties to bind cables Cut off excess cable tie cleanly with no sharp edges after bundling cables as shown in Figure D 2 Figure D 2...

Страница 43: ...ed and prevented from loosening as shown in Figure D 4 Figure D 4 Fastening Cable Lugs Note Flat washer Nut Spring washer Flat washer When using a stiff cable fix it near the cable lug to avoid stress...

Страница 44: ...conditions such as windstorm and heavy rain as well as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the resid...

Страница 45: ...Ruijie RG NBS3100 Series Switches Hardware Installation and Reference Guide 45...

Отзывы: