Preparation before Installation 

 

supplies (that is, Action current of the leakage protector/2/Maximum leakage current of each power supply = 30/2/3.5 

=  4.28).  In  other  words,  the  leakage  protector  with  30  mA  rated  action  current supports  no  more  than  four  power 

supplies. In this case, the sixteen power supplies in the system require at least four leakage protectors with 30 mA 

rated action current and each leakage protector supports four power supplies. If power supplies in a system differ in 

models, the rated leakage action current of each leakage protector divided by two is greater than the sum of maximum 

leakage currents of all the power supplies. The rated leakage non-action current of a leakage protector shall be 50% 

of the leakage action current. Take a leakage protector with 30 mA rated leakage action current as an example. The 

rated leakage non-action current shall be 15 mA. When the leakage current is below 15 mA, the protector shall not 

act. Otherwise, misoperation may easily occur due to high sensitivity and thus the leakage protector trips, devices 

are powered off, and services are interrupted. 

 

To guarantee personal safety, the rated leakage action current of each leakage protector in the system must be equal 

to or less than 30 mA (human body safety current is 30 mA). When twice of the total leakage current of the system is 

greater than 30 mA, the system must be equipped with two or more leakage protectors. 

 

For the leakage current value of each power supply model, see the power supply model parameter table in Chapter 

1. 

2.1.4  Static Discharge Damage Prevention 

To prevent damage from static electricity, pay attention to the following: 

 

Proper grounding of grounding screws on the back panel of the device. 

 

Indoor dust prevention 

 

Proper humidity conditions 

2.2  Installation Site Requirements 

To ensure the normal working and a prolonged durable life of the equipment, the installation site must meet the following 

requirements. 

2.2.1  Installation Site 

If the router is installed in the cabinet, the following requirements shall be met: 

 

Make sure sufficient room has been reserved for the air intake and air vent of router to facilitate the heat elimination 

of the router chassis.   

 

Make sure the cabinet is equipped with a good ventilation and cooling system. 

 

Make sure the cabinet and workbench is steady enough and capable of withstanding the weight of the router and its 

accessories. 

 

Make sure the cabinet is properly grounded. 

2.2.2  Ventilation 

For the RG-EG210G-E router, a sufficient space (at least 10 cm distances from both sides and the back plane of the 

cabinet) should be reserved at the ventilation openings to ensure the normal ventilation. After various cables have been 

connected, they should be arranged into bundles or placed on the cabling rack to avoid blocking the air inlets. It is 

Содержание RG-EG210G-E Series

Страница 1: ...Ruijie RG EG210G E Series Routers Hardware Installation and Reference Guide...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...ite https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical Suppo...

Страница 4: ...tor familiar with mainstream router configuration commands can use this device without training 1 1 RG EG210G E Specifications Model RG EG210G E CPU Dual core CPU with the clock speed of 1 35GHz Flash...

Страница 5: ...ference in which case the user may be required to take adequate measures Appearance Figure 1 1 Appearance of RG EG210G E Figure 1 2 Front Panel of RG EG210G E Note 1 System status LED 2 Reset button 3...

Страница 6: ...ce in the specified environment 10 cm distance space should be reserved at both sides and the back plane of the cabinet to allow air circulation It is recommended to clean the device once every 3 mont...

Страница 7: ...supply and damp wet ground or floor Before installing the device find out the location of the emergency power supply switch in the room First cut off the power supply in the case of an accident Try to...

Страница 8: ...urrent is 30 mA When twice of the total leakage current of the system is greater than 30 mA the system must be equipped with two or more leakage protectors For the leakage current value of each power...

Страница 9: ...E Series Router Temperature Relative Humidity 0 C to 40 C 32 F to 104 F 10 to 90 40 F to 158 F The requirements for the sampling site of the temperature and humidity in the operating environment of t...

Страница 10: ...unding required for EMC design includes shielding ground filter ground noise and interference suppression and level reference All the above constitute the comprehensive grounding requirements The resi...

Страница 11: ...of the electrical equipment and anti lightning grounding device Keep the equipment away from high power radio transmitter radar transmitting station and high frequency large current device Measures m...

Страница 12: ...g points Whether ventilation requirements are met for the device Whether the requirements of temperature and humidity are met for the device Whether power cables are already laid out and whether the r...

Страница 13: ...le management bracket and cables Install the tray and wiring layer on the cabinet according to the configuration of one cabinet with one device installed or one cabinet with multiple devices installed...

Страница 14: ...he building In most buildings the neutral point of a power supply has been grounded during the construction You need to make sure the power supply is properly grounded Please take the following steps...

Страница 15: ...uijie RG EG210G E Series Routers Hardware Installation and Reference Guide Installing the Router Verify that the fibers and twisted pairs match the ports Verify that the cables have been bound properl...

Страница 16: ...onnect to the SSID for configuration Figure 4 1 Schematic Diagram of the Configuration Environment 4 2 Startup Check 4 2 1 Checking before the Device is Powered on The router is fully grounded The pow...

Страница 17: ...ters Hardware Installation and Reference Guide System Debugging 4 3 Configuring Router To use the router more configuration should be made on the device Please refer to the corresponding command refer...

Страница 18: ...set Button for more than 5 seconds to restore the default password The status indicator is not on after the device is started The power supply module does not supply power Check whether the power sock...

Страница 19: ...all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000BASE T In addition to the above cables the 10...

Страница 20: ...or the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4...

Страница 21: ...seven times their respective diameters The bend radius of a common coaxial cable should be greater than seven times its diameter The bend radius of this type of cables that often bend or suffer remova...

Страница 22: ...rack and cabling slot inside and outside the cabinet should be smooth without sharp corners The metal hole traversed by cables should have a smooth and fully rounding surface or an insulated lining P...

Страница 23: ...running or cause device damage or cable damage during commissioning The power cords cannot be bundled on the guide rails of moving parts The power cables connecting moving parts such as door grounding...

Страница 24: ...bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table B 1 Cable Bunch Diameter mm Binding Space mm 10 80 150 10 30 150 200 30 200 300...

Отзывы: