Ruijie RG-AP180 Series Скачать руководство пользователя страница 3

·

 

 

 

Preface 

Thank you for using our products. This manual will guide you through the installation of the access point. 

 

Scope 

It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it 

is assumed that the users are already familiar with the related terms and concepts. 

 

Obtaining Technical Assistance 

 

Ruijie Networks Website: 

https://www.ruijienetworks.com/

 

 

Technical Support Website

https://ruijienetworks.com/support

 

 

Case Portal

https://caseportal.ruijienetworks.com

 

 

Community

https://community.ruijienetworks.com

 

 

Technical Support Email

[email protected]

 

 

Skype

[email protected]

 

 

Related Documents 

Documents 

Description 

Configuration Guide 

Describes network protocols and related mechanisms that supported by the 

product, with configuration examples.   

Command Reference 

Describes the related configuration commands, including command modes, 

parameter descriptions, usage guides, and related examples. 

 

 

Documentation Conventions 

The symbols used in this document are described as below: 

 

 

This symbol brings your attention to some helpful suggestions and references. 

 

 

This symbol means that you must be extremely careful not to do some things that may damage the device or cause 

data loss. 

Содержание RG-AP180 Series

Страница 1: ...Ruijie RG AP180 Series Access Points Hardware Installation and Reference Guide V1 00...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...ty https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes ne...

Страница 4: ...with Ruijie RG WS Wireless Controller Series wireless data forwarding high performance security and access control can be accomplished with ease 1 1 Technical Specifications Table 1 1 Technical Specif...

Страница 5: ...l power supply DC 12V 1A PoE IEEE 802 3af 802 3at compliant compatible Power Consumption 10W Bluetooth Bluetooth 4 0 iBeacon Temperature Operating 10 C to 45 C 14 F to 113 F Storage 40 C to 70 C 40 F...

Страница 6: ...Reference Guide Product Overview Figure 1 2 Bottom View of RG AP180 Note 1 Four 10 100 1000Base T LAN ports Figure 1 3 Side View of RG AP180 Note 1 Micro USB management port Console 2 Reset button 3 P...

Страница 7: ...AP is powered off Or the AP is in Silent mode which can be disabled via software Fast blinking green before solid green 2 5Hz fast blinking green Initialization is in progress The AP is operational F...

Страница 8: ...P connection is established At least one client is associated 1 4 Reset Button To reset the AP you need to keep the reset button pressed for 2s or less To restore default settings you need to keep the...

Страница 9: ...should be free from water flooding seepage dripping or condensation The installation site shall be selected according to network planning and features of communications equipment and considerations s...

Страница 10: ...meter Outer Diameter Insertion Depth Polarity 2 1mm 5 5mm 10mm Inner pole positive Outer pole negative The DC input power should be greater than the power actually consumed by the system The input pow...

Страница 11: ...tive measures should be taken for the power system to prevent the interference from the electric grid The working ground of the routers should be properly separated and kept as far as possible from th...

Страница 12: ...all the device in a well ventilated location Do not subject the device to high temperatures Keep away from high voltage cables Install the device indoors Do not expose the device in a thunderstorm or...

Страница 13: ...ype faceplate that is mounted on the wall Skip this step if the faceplate has not been mounted Figure 3 1 Loosen Screws on the Faceplate 2 Connect the uplink cable to the UpLNK port Figure 3 2 Connect...

Страница 14: ...in the way as shown in the following figure Figure 3 4 Install the Cover 5 Compete the installation Figure 3 5 Cover for RG AP180 3 4 Removing the Plate Cover You can use a straight screwdriver to re...

Страница 15: ...Hardware Installation and Reference Guide Installing the Access Point...

Страница 16: ...ommended that you check the following to ensure normal operation of the AP Check if any message is displayed on the Web based configuration interface for the wireless controller Check if the LED works...

Страница 17: ...the Ethernet link is up But the CAPWAP connection is faulty Blinking green 0 4Hz The AP is operational The CAPWAP connection is OK At least one client is associated with the AP Blinking green one flas...

Страница 18: ...cable is connected Verify that the device at the other end of the Ethernet cable is working properly And then verify that the Ethernet cable is capable of providing the required data rate and is prope...

Страница 19: ...imum distance of 100 meters 328 feet 1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure A 1 Figure A 1 1000BASE T Connection 10BASE T uses Category 3 4 5...