Hardware Installation and Reference Guide Product Overview
6
Caution
The power adapter is optional. If you need to use a DC power adapter for power supply, please purchase an
adapter that meets the corresponding safety requirements.
1.3.5
Environment and Reliability
Table 1-8 Environment and Reliability
Item
Description
Temperature
Operating: -10°C to 50°C (14°F to 122°F)
Storage: -40°C to 70°C (-40°F to 158°F)
At a height between 3000 m (9842.52 ft.) to 5000 m (16404.20 ft.) above the sea
level, every time the altitude increases by 220 m (721.78 ft.), the maximum
temperature decreases by 1°C (1.8°F).
Humidity
Operating: 0% to 95% (RH), non-condensing
Storage: 0% to 95% (RH), non-condensing)
Safety
Certifications
GB 4943.1-2011, IEC 62368-1
EMC Certifications
EN 300386, GB/T 19286-2015, GB/T 17618-2015
1.4
LEDs and Button
Table 1-9 Fit AP
State
Frequency
Meaning
Off
N/A
The AP is NOT receiving power or the AP is in Do Not Disturb mode,
which can be disabled by software.
Blinking green
3Hz
uBoot program initialization is in progress.
Solid green
N/A
Main program initialization is in progress.
Blinking red
3Hz
Initialization is complete, but no Ethernet activity.
2Hz
Locate the AP.
Solid orange
N/A
Initialization is complete, and the AP is establishing a CAPWAP
connection with an AC.
Blinking orange
3Hz
Firmware upgrade in progress. Do not power off the AP.
Solid blue
N/A
Normal operation, but no wireless clients are associated with the AP.
Blinking blue
3Hz
Normal operation, and at least one wireless client is associated with the
AP.
Reset button
Pressed
for
less than 2s
Reboot the device.