time is no less than 100ms, if the machine is idle currently, it will
start work. If the machine is running currently, the work will be
suspended. If the machine is in a paused state currently, the
suspended work will be restarted, that is, the function of the foot
switch is similar to the “Start/Pause” key on the keyboard. If the
time between the second stepping down of the foot switch and
the first stepping down is less than 100 milliseconds, the second
pedal action will be considered invalid by the motherboard.
3
DrProc
Dedicated input, protection signal input, if the machine needs to
be protected in a certain state (such as cover-opening protection),
the protection signal is input from this pin. This pin can be
enabled or disabled. When the pin is disabled, the signal will not
be queried by the mainboard. If the pin is enabled, when a high
voltage is input or the input port is suspended, the machine is
protected, the ongoing work will be suspended, and the laser will
be turned off.
4
Shot
General input, laser hardware pulse switch input port, when a low
voltage is connected, laser pulse can be performed, while a high
voltage is connected, laser pulse do not be performed.
5
IN1
General input, function reserved.
6
+24V
Power +24V (output)
4.8 Four-axis limit input interface CN3/CN4
X/Y axis limit interface CN4
PIN
Signal
Definition
1
GND
Power ground (output)
2
LmtY-
Y-, the limit of Y-axis moving to coordinate 0
3
LmtY+
Y+, the limit of Y-axis moving to the maximum coordinate
4
LmtX-
X-, the limit of X-axis moving to coordinate 0
5
LmtX+
X+, the limit of X-axis moving to the maximum coordinate
6
+5V
Power 5V (output)
The limit polarity is optional. When the axis reaches the limit position, a low voltage signal is triggered,
the LED corresponding light are on. When the axis leaves the limit position, a high voltage signal will be
triggered or a limit signal will be disconnected to make the limit indicator lights are off.Then the limit
polarity is negative conversely, if the corresponding indicator light is off when the axis gets close to the
limit, and the corresponding indicator light is on when it leaves the limit, then the limit polarity is