Miknetum MGR 400
16
h)
Check radial shaft seals for leak tightness; replace otherwise!
i)
Read the error memory (frequency converter)!
5.3
Repair and spare parts
As a damaged part on a machine is usually damaged due to causes
unrelated to the part, always carry out a fault diagnosis.
For this reason, contact our Service Hotline at +49 7748-523-11 for
spare parts or technical faults. Please keep the machine type and
number ready.
6
Disposal
1.
The machine contains a cooling system filled with the
refrigerant R404A. It must be pumped off by a refrigeration
installer and must then disposed of correctly!
2.
The following components contain oil:
a.
Lid drive
b.
Tumbling stripper arm drive
c.
Mixing arm drive
d.
Slewing gear
e.
Lifting aid drive
f.
Vacuum pump
g.
Compressor (cooling unit)
All gears/motors except for the compressor are equipped with
oil draining screws. The compressor must be drilled open for
draining the oil. Subsequently, dispose of the oil properly!
3.
All other materials must be sorted and disposed of at a
recycling facility!