background image

Serial Ports:

2 RS485/RS422/RS232

DB9 or RJ45

Up to 230kbp

Integrated Power Supply

Universal high-voltage range:

88-300VDC or 85 - 264VAC

Popular low voltage DC ranges: 24VDC

(9-36VDC), 48VDC (36-59VDC)

Dual Isolated DC power inputs

Critical Alarm Relay

Form-C failsafe contact relay: 

1A@30VDC

RuggedSwitch™ RS920W 

Rugged Construction:

20 AWG. galvanized

steel enclosure

Conformal coating

(optional)

Operating Temperature

-40

o

C to +85

o

C

No Fans

Mounting Options

Din Rail

Panel Mount

Hazardous Location

Certification

Class1, Division2

www.RuggedCom.com

2

RuggedWireless™ RS920W

RuggedWireless

TM

RS920W

Wireless Serial Device Server with Ethernet over VDSL Interface

Wireless Specifications

IEEE 802.11b/g compliant provides simultaneous support for

both IEEE802.11b and IEEE802.11g wireless clients.

Can be configured as an access, client or bridge device

Antenna type: Removable, upgradeable 3dBi Antenna with 
R-SMA (male) connector

Operating channels/frequency-range:

11 channels, 2.400 - 2.4720 Ghz (US, Canada)

13 channels, 2.400 - 2.4835 Ghz (ETSI)

14 channels, 2.400 - 2.4970 Ghz (Japan)

Data rates:

IEEE 802.11b: 11/5.5/2/1 Mbps with automatic failback

IEEE 802.11g: 54/48/36/24/18/12/9/6 Mbps with
automatic failback

Modulation technology:

IEEE 802.11b: DSSS over CCK (11/5 Mbps), DQPSK 
(2 Mbps), DBPSK (1 Mbps)

IEEE 802.11g: OFDM over 64QAM, 16QAM, QPSK, BPSK

Transmit power:

IEEE 802.11b: 20dBm nominal @ 11 Mbps

IEEE 802.11g: 16dBm nominal @ 54 Mbps

Receiver sensitivity:

IEEE 802.11b: -88dBm @ 11 Mbps with 8% FER

IEEE 802.11g: -74dBm @ 54 Mbps with 10% FER

EoVDSL Port

One EoVDSL port 

RJ11 connector

Symmetrics data rates 

up to 50Mbps

Antenna

Standard 3dBi

Various antenna option

packages available

Содержание RuggedWireless RS920W

Страница 1: ...of RJ45 Serial Fiber Interface ST available Ethernet Over VDSL Port Characteristics Up to 4km LAN segments Symmetric data rates up to 50 Mbps Automatically selects fastest data rate based on distance...

Страница 2: ...support for both IEEE802 11b and IEEE802 11g wireless clients Can be configured as an access client or bridge device Antenna type Removable upgradeable 3dBi Antenna with R SMA male connector Operatin...

Страница 3: ...and mesh Ethernet networks that incorporate redundant links that are pruned to prevent loops eRSTP yields worst case fault recovery1 of 5ms times the bridge diameter and allows rings of up to 80 swit...

Страница 4: ...ical equipment ROS limits this by filtering broadcast frames with a user defined threshold Port Mirroring ROS can be configured to duplicate all traffic on one port to a designated mirror port When co...

Страница 5: ...fe Relay output 5kV Fail Safe Relay output N A D C Power ports 5kV 5kV N A A C Power ports 5kV 5kV N A Notes 1 Class 2 refers to Measuring relays and protection equipment for which a very high securit...

Страница 6: ...CSA C22 2 No 60950 UL 60950 EN60950 Laser Eye Safety FDA CDRH Complies with 21 CFR Chapter1 Subchapter J Warranty 5 Years Applicable to design or manufacturing related product defects Technical Specif...

Страница 7: ...tions Parameter Fiber Port Type Mode Multimode Singlemode Connectors MTRJ ST SC LC LC SC ST Typical Dist km 2 20 50 90 Optical Wavelength nm 1310 1310 Cable SizeCore Cladding um 50 or 62 5 125 8 or 9...

Страница 8: ...ireless Options W1 802 11i US North America W2 802 11i EU European Union coming soon W3 802 11i CH China coming soon W4 802 11i AU Australia coming soon Power Cables 43 10 0008 Bare wire 43 10 0007 wi...

Отзывы: