Wireless Serial Device Server with Ethernet over VDSL Interface

RS920W    -_____  -____  -____  -____  -_____                  

PS  

M  

S   

VV 

WW             

PS: Power Supply

.

24 = 24VDC (9-36VDC)

.

48 = 48VDC (36-72VDC)

.

HI = 85-264VAC or 88-300VDC

M: Mounting options

.

D = Din Rail 

.

P = Panel Mounting

.

N = None

S: Serial Port Options

.

XX = None

S1 = 2 x RS232/422/485 DB9

.

S2 = 2 x RS232/422/485 RJ45

.

S3 = 2 x Fiber 850nm ST

VV: VDSL Interface

.

V1 = Standard reach (<2.5km)

.

V2 = Long Reach (4km) Master / CO

.

V3 = long Reach (4km) /CPE

WW: Wireless Options

.

W1 = 802.11i - US (North America)

.

W2 = 802.11i - EU (European Union) (coming soon)

.

W3 = 802.11i - CH (China) (coming soon)

.

W4 = 802.11i - AU (Australia) (coming soon)

Power Cables

43-10-0008 - Bare-wire
43-10-0007 - with lugs

For additional information on our products and
services, please visit our website at: www.RuggedCom.com

RuggedCom Inc.
30 Whitmore Road
Woodbridge, Ontario, Canada L4L 7Z4

Tel: 

(905) 856-5288 

Fax:

(905) 856-1995

Toll Free:

(888) 264-0006

Technical Support Center: 

(866) 922-7975 or (954) 922-7975

© 2007 RuggedCom Inc.
RuggedWireless is a trademark of RuggedCom Inc.
Ethernet is a trademark of the Xerox Corporation.
Patent Pending
All specifications in this document are subject to change without notice.
Rev 1  -F

Order Code

Содержание RuggedWireless RS920W

Страница 1: ...of RJ45 Serial Fiber Interface ST available Ethernet Over VDSL Port Characteristics Up to 4km LAN segments Symmetric data rates up to 50 Mbps Automatically selects fastest data rate based on distance...

Страница 2: ...support for both IEEE802 11b and IEEE802 11g wireless clients Can be configured as an access client or bridge device Antenna type Removable upgradeable 3dBi Antenna with R SMA male connector Operatin...

Страница 3: ...and mesh Ethernet networks that incorporate redundant links that are pruned to prevent loops eRSTP yields worst case fault recovery1 of 5ms times the bridge diameter and allows rings of up to 80 swit...

Страница 4: ...ical equipment ROS limits this by filtering broadcast frames with a user defined threshold Port Mirroring ROS can be configured to duplicate all traffic on one port to a designated mirror port When co...

Страница 5: ...fe Relay output 5kV Fail Safe Relay output N A D C Power ports 5kV 5kV N A A C Power ports 5kV 5kV N A Notes 1 Class 2 refers to Measuring relays and protection equipment for which a very high securit...

Страница 6: ...CSA C22 2 No 60950 UL 60950 EN60950 Laser Eye Safety FDA CDRH Complies with 21 CFR Chapter1 Subchapter J Warranty 5 Years Applicable to design or manufacturing related product defects Technical Specif...

Страница 7: ...tions Parameter Fiber Port Type Mode Multimode Singlemode Connectors MTRJ ST SC LC LC SC ST Typical Dist km 2 20 50 90 Optical Wavelength nm 1310 1310 Cable SizeCore Cladding um 50 or 62 5 125 8 or 9...

Страница 8: ...ireless Options W1 802 11i US North America W2 802 11i EU European Union coming soon W3 802 11i CH China coming soon W4 802 11i AU Australia coming soon Power Cables 43 10 0008 Bare wire 43 10 0007 wi...

Отзывы: