background image

Chapter 5

Technical Specifications

RUGGEDCOM RSG2300

Installation Guide

30

Failsafe Relay Specifications

Section 5.2

Failsafe Relay Specifications

Parameter

Value (Resistive Load)

Max Switching Voltage

240 VAC, 125 VDC

Rated Switching Current

2 A @ 240 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC

Maximum Switching Capacity

150 W, 500 VA

Section 5.3

Supported Networking Standards

Standard

10 Mbps Ports

100 Mbps Ports

1000 Mbps Ports

Description

IEEE 802.3

ü

10BaseT/10BaseFL

IEEE 802.3u

ü

100BaseTX/100BaseFX

IEEE 802.3x

ü

ü

ü

Flow Control

IEEE 802.3z

ü

1000BaseLX

IEEE 802.3ab

ü

1000BaseTx

IEEE 802.3ad

ü

Link Aggregation

IEEE 802.1D

ü

ü

ü

MAC Bridges

IEEE 802.1D

ü

ü

ü

Spanning Tree Protocol (STP)

IEEE 802.1p

ü

ü

ü

Class of Service (CoS)

IEEE 802.1Q

ü

ü

ü

VLAN (Virtual LAN) Tagging

IEEE 802.1w

ü

ü

ü

Rapid Spanning Tree Protocol (RSTP)

IEEE 802.1x

ü

ü

ü

Port-Based Network Access Control

IEEE 802.1Q-2005

(formerly 802.1s)

ü

ü

ü

Multiple Spanning Tree Protocol (MSTP)

Section 5.4

Copper Ethernet Port Specifications

The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM

RSG2300.

NOTE

• Maximum segment length is greatly dependent on factors such as fiber quality, and the number

of patches and splices. Consult a Siemens sales associate when determining maximum segment

distances.

• All optical power numbers are listed as dBm averages.

Содержание RuggedSwitch RSG2300

Страница 1: ...RUGGEDCOM RSG2300 Installation Guide 07 2018 RC1046 EN 12 Preface Introduction 1 Installing Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6...

Страница 2: ...t and or networks They are important components in a holistic industrial security concept With this in mind Siemens products and solutions undergo continuous development Siemens recommends strongly th...

Страница 3: ...Siemens Address Siemens Canada Ltd Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E mail ruggedcom info...

Страница 4: ...RUGGEDCOM RSG2300 Installation Guide iv...

Страница 5: ...Twisted Pair Data Ports 4 1 5 2 Gigabit Ethernet 1000Base TX Cabling Recommendations 5 1 5 3 Supported Fiber Optic Cables 5 Chapter 2 Installing Device 7 2 1 General Procedure 7 2 2 Unpacking the Dev...

Страница 6: ...9 5 1 Power Supply Specifications 29 5 2 Failsafe Relay Specifications 30 5 3 Supported Networking Standards 30 5 4 Copper Ethernet Port Specifications 30 5 5 Fiber Optic Ethernet Port Specifications...

Страница 7: ...ssing Documentation Training Customer Support Alerts The following types of alerts are used when necessary to highlight important information DANGER DANGER alerts describe imminently hazardous situati...

Страница 8: ...nique mix of IT Telecommunications expertise combined with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s applicati...

Страница 9: ...Installation Guide Preface Customer Support ix Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the...

Страница 10: ...Preface RUGGEDCOM RSG2300 Installation Guide x Customer Support...

Страница 11: ...G2300 is packaged in a rugged galvanized steel enclosure with industrial grade DIN panel or 48 cm 19 in rack mount mounting options The RUGGEDCOM RSG2300P additionally offers 802 3af standard Power ov...

Страница 12: ...Screw or pluggable terminal blocks for reliable maintenance free connections CSA UL 60950 1 safety approved to 85 C 185 F Section 1 2 Description The RUGGEDCOM RSG2300 features various ports controls...

Страница 13: ...cator LED illuminates when an alarm condition exists Power Module Indicator LEDs The power module indicator LEDs indicate the status of the power modules Green The power supply is supplying power Red...

Страница 14: ...ust be done in accordance with local regulations Section 1 5 Cabling Recommendations Before connecting the device be aware of the recommendations and considerations outlined in this section CONTENTS S...

Страница 15: ...iance 5e Yes No action required New installations should be designed with Category 5e or higher 6 Yes No action required 6 Yes Connector and wiring standards to be determined Follow these recommendati...

Страница 16: ...Chapter 1 Introduction RUGGEDCOM RSG2300 Installation Guide 6 Supported Fiber Optic Cables...

Страница 17: ...iation exposure IMPORTANT This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly a...

Страница 18: ...ing the Device The RUGGEDCOM RSG2300 is designed for maximum mounting and display flexibility It can be equipped with connectors that allow it to be installed in a 48 cm 19 in rack 35 mm 1 4 in DIN ra...

Страница 19: ...s not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space Do not exceed the maxi...

Страница 20: ...l For DIN rail installations the RUGGEDCOM RSG2300 can be equipped with panel DIN rail adapters pre installed on each side of the chassis The adapters allow the device to be slid onto a standard 35 mm...

Страница 21: ...el Mounting 1 Screw 2 Panel DIN Rail Adapter 2 Install the supplied screws to secure the adapters to the panel Section 2 4 Connecting the Failsafe Alarm Relay The failsafe relay can be configured to l...

Страница 22: ...hock or vibration CAUTION Electrical hazard risk of damage to the device Disconnect the device from the power supply if power input is above or below the specified input range For more information ref...

Страница 23: ...suppression circuitry during testing CAUTION Electrical hazard risk of damage to equipment Do not connect AC power cables to a DC power supply terminal block Damage to the power supply may occur IMPOR...

Страница 24: ...and 6 to connect the surge ground terminals to the chassis ground terminal The surge ground terminals are used as the ground conductor for all surge and transient suppression circuitry internal to th...

Страница 25: ...n Guide Chapter 2 Installing Device Wiring Examples 15 Section 2 5 2 Wiring Examples The following illustrate how to connect power to single and dual power supplies Figure 8 Single AC Power Supply Fig...

Страница 26: ...Chapter 2 Installing Device RUGGEDCOM RSG2300 Installation Guide 16 Wiring Examples Figure 10 Dual AC Power Supply Figure 11 Dual DC Power Supply...

Страница 27: ...RUGGEDCOM RSG2300 Installation Guide Chapter 2 Installing Device Wiring Examples 17 Figure 12 Dual AC DC Power Supply...

Страница 28: ...Chapter 2 Installing Device RUGGEDCOM RSG2300 Installation Guide 18 Wiring Examples...

Страница 29: ...ation directly to the RS232 console port to access the boot time control and ROS interfaces The console port provides access to ROS s console and Web interfaces IMPORTANT The serial console port is in...

Страница 30: ...ect any of the available Ethernet ports on the device to a management switch and access the ROS console and Web interfaces via the device s IP address For more information about available ports refer...

Страница 31: ...mbination of two port fiber or copper Ethernet modules up to 100 Mbps Slots 3 and 4 support any combination of two port Gigabit Ethernet 1 Gbps ports Slots 5 6 and 7 house 8 port 10 100TX copper RJ45...

Страница 32: ...connectors The RJ45 connectors are directly connected to the chassis ground on the device and can accept CAT 5 shielded twisted pair STP cables WARNING Electric shock hazard risk of serious personal...

Страница 33: ...8 Reserved Do Not Connect BI_DD Receive Data or Bi Directional Pair D Specifications For specifications on the available copper Ethernet ports refer to Section 5 4 Copper Ethernet Port Specifications...

Страница 34: ...ransceivers approved by Siemens for RUGGEDCOM products Siemens accepts no liability as a result of performance issues related in whole or in part to third party components SFP Transceiver Order Code S...

Страница 35: ...onnector connectors 2 1 Figure 21 SC Port 1 Tx Connector 2 Rx Connector CONTENTS Section 4 4 1 Installing a GBIC Optical Port Section 4 4 2 Removing a GBIC Optical Port Section 4 4 1 Installing a GBIC...

Страница 36: ...sert in only one orientation Do not force the port into the module 4 Remove the dust plug from the socket and store for future use 5 Squeeze the latches on either side of the port and insert the port...

Страница 37: ...trostatic discharge ESD This can be accomplished by wearing an ESD preventive wrist trap connected to either the chassis ground connector or a bare metal surface on the router switch 2 Disconnect the...

Страница 38: ...Chapter 4 Communication Ports RUGGEDCOM RSG2300 Installation Guide 28 Removing a GBIC Optical Port...

Страница 39: ...ction 5 1 Power Supply Specifications The RUGGEDCOM RSG2300 can be equipped with the following power supplies CAUTION Electrical hazard risk of damage to the device Disconnect the device from the powe...

Страница 40: ...1000BaseTx IEEE 802 3ad Link Aggregation IEEE 802 1D MAC Bridges IEEE 802 1D Spanning Tree Protocol STP IEEE 802 1p Class of Service CoS IEEE 802 1Q VLAN Virtual LAN Tagging IEEE 802 1w Rapid Spanning...

Страница 41: ...ptical Specifications Tx dBm Mode Connector Type Cable Type m Tx nm j Minimum Maximum Rx Sensitivity dBm Rx Saturation dBm Distance km k Power Budget dB MM ST 62 5 125 850 16 9 34 11 2 2 18 MM ST 50 1...

Страница 42: ...ifications NOTE These transceivers utilize a distributed feedback DFB type laser and are rated for 20 to 85 C 4 to 185 F operation only Tx dBm p Mode Connector Type Cable Type m n Tx nm o Minimum Maxi...

Страница 43: ...number of patches and splices Consult a Siemens sales associates when determining maximum segment distances v Operating temperature range of 25 to 85 C 13 to 185 F Section 5 6 Operating Environment T...

Страница 44: ...Specifications RUGGEDCOM RSG2300 Installation Guide 34 Dimension Drawings NOTE Dimensional tolerances are in accordance with ISO 2768 mK unless otherwise stated 303 28 285 24 438 15 44 45 0 8 Figure 2...

Страница 45: ...M RSG2300 Installation Guide Chapter 5 Technical Specifications Dimension Drawings 35 461 01 6 35 31 75 6 35 4 57 308 10 28 95 12 70 25 40 51 05 11 68 21 08 32 64 314 71 479 29 Figure 25 Rack Mount Di...

Страница 46: ...4 5 6 7 8 11 12 9 10 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 P4 P3 P6 P5 P7 P8 P2 P1 P10 P9 P12 P11 P14 P13 P16 P15 P18 P17 P20 P19 P22 P21 P24 P23 P26 P25 P28 P27 P30 P29 P32 P31...

Страница 47: ...which the RUGGEDCOM RSG2300 complies CONTENTS Section 6 1 1 CSA Section 6 1 2 European Union EU Section 6 1 3 FCC Section 6 1 4 FDA CDRH Section 6 1 5 ISED Section 6 1 6 ISO Section 6 1 7 ACMA Sectio...

Страница 48: ...y is available from Siemens Canada Ltd For contact information refer to Contacting Siemens Section 6 1 3 FCC This device has been tested and found to comply with the limits for a Class A digital devic...

Страница 49: ...182 of the Radiocommunications Act 1992 Radiocommunications Labelling Electromagnetic Compatibility Notice 2008 made under Section 182 of the Radiocommunications Act 1992 Radiocommunications Complian...

Страница 50: ...Industrial Environments IEC 61850 3 Communication Networks and Systems in Substations Part 3 General Requirements Section 6 2 EMC and Environmental Type Tests The RUGGEDCOM RSG2300 has passed the foll...

Страница 51: ...7 Ripple on DC Power Supply DC Power Ports 15 3 IEC 61000 4 29 Voltage Dips and Interrupts DC Power Ports 30 for 0 1 s 60 for 0 1 s 100 for 0 05 s Signal Ports 2 kV Fail Safe Relay Output DC Power Por...

Страница 52: ...fferential mode 1 MHz Signal Ports 5 kV Fail Safe Relay Output DC Power Ports 5 kV HV Impulse AC Power Ports 5 kV Signal Ports 2 kV DC Power Ports 2 kV Dielectric Strength AC Power Ports 2 kV Damped O...

Отзывы: