Installation
2 Installation
2.1 Rack Mounting
Figure 12: RS2000 Family 19” Rack Mount Adapters
Figure 13: Rack mount adapter mounting location
The RSG2000 family of products can be rack mounted using the included rack mount
adapter assemblies shown in Figure 12. Secure the one rack mount adapter to the front
of each side of the chassis using the included black PAN head philips screws in the
positions shown in Figure 14. The entire chassis can then be mounted to a standard 19”
rack. An additional two rack mount adapters are included to optionally secure the rear of
the chassis in high-vibration, or seismically active locations.
Note
: Since heat within the RSG2100 is channeled to the enclosure, it is recommended
that 1 rack unit of space (1.75”) be kept unpopulated and free of equipment above each
RSG2100 series product to allow for a small amount of convectional airflow. Although
forced airflow is not necessary, any increase in airflow will result in a reduction of
ambient temperature that will improve long-term reliability of all equipment mounted
within the rack space.