background image

 

 

RuggedSwitch

® 

RSG2100 

 

19-Port Modular Managed Ethernet Switch with 

Gigabit Uplink Ports

 

 
 
 

 

 
 
 

Installation Guide 

June 22, 2009 

 
 
 

www.ruggedcom.com 

Содержание RuggedSwitch RSG2100

Страница 1: ...RuggedSwitch RSG2100 19 Port Modular Managed Ethernet Switch with Gigabit Uplink Ports Installation Guide June 22 2009 www ruggedcom com...

Страница 2: ...n given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions We appreciate any suggested improvements We reserve the right to make technical imp...

Страница 3: ...m and is classified as a CLASS 1 LASER PRODUCT CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure This pro...

Страница 4: ...rength HIPOT Testing 21 2 5 Failsafe Alarm Relay Wiring and Specifications 22 2 6 Console Port Wiring 23 2 7 RJ45 Twisted Pair Data Ports 24 2 8 Gigabit Ethernet 1000Base Tx Cabling Recommendations 25...

Страница 5: ...ure 18 AC Power supply wiring examples 18 Figure 19 DC Power supply wiring examples 19 Figure 20 DC And AC power supply wiring examples 20 Figure 21 Dielectric Strength HIPOT Testing 21 Figure 22 Fail...

Страница 6: ...nations Optional front or rear mount connectors make the RSG2100 highly versatile for any application and can support multiple fiber connectors ST MTRJ LC SC without loss of port density The RSG2100 i...

Страница 7: ...24 or 48 VDC Terminal blocks for reliable maintenance free connections CSA UL 60950 safety approved to 85 C Simple Plug and Play Operation Automatic learning of up to 8192 MAC addresses Auto negotiati...

Страница 8: ...Rail or directly onto a panel For rack mount installations the RSG2000 series can be ordered with connectors on the front of the unit or can located on the rear of the chassis to allow for all data a...

Страница 9: ...t module is equipped with two LEDs that indicate link activity status information The LED will be solid for ports with link and will blink for activity The diagram in Figure 3 highlights the port and...

Страница 10: ...s or tabs towards the top of the unit Modules located on the bottom row of the device have locking mechanisms or tabs towards the bottom of the device The drawings in the following figures show each f...

Страница 11: ...Product Overview Figure 8 100FX 1000LX ST connector Figure 9 1000LX GBIC Module and SC connector Figure 10 1000LX SFP mini GBIC Module and LC connector RuggedSwitch RSG2100 11 RuggedCom...

Страница 12: ...tors conveying Link Activity Duplex or Speed via push button control System reset via push button if held for 5 seconds Figure 11 RSG2000 LED Display Panel Device status LEDs exist to provide a quick...

Страница 13: ...le port LED colours and the corresponding description Mode Color Description Green Solid Link Green Blinking Activity Status Off No link Green Solid Full Duplex operation Orange Solid Half Duplex oper...

Страница 14: ...unted to a standard 19 rack An additional two rack mount adapters are included to optionally secure the rear of the chassis in high vibration or seismically active locations Note Since heat within the...

Страница 15: ...e panel DIN adapters to be mounted on each side of the chassis enclosure The adapter allows for the chassis to be mounted on the standard 1 DIN rail using the grooves in the adapter secured using the...

Страница 16: ...connections for PS1 PS2 and the fail safe relay are located on the terminal block as shown in Figure 15 and Figure 16 The RSG2000 Family chassis ground connection shown in Figure 17 uses a 6 32 screw...

Страница 17: ...st be disconnected from Chassis Ground during HIPOT dielectric strength testing 3 PS1 Neutral PS1 Neutral is connected to the negative terminal if the power source is DC or to the Neutral terminal if...

Страница 18: ...d equipment A 250VAC appropriately rated circuit breaker must be installed Equipment must be installed according to the applicable country wiring codes When equipped with two HI voltage power supplies...

Страница 19: ...ppropriately rated circuit breaker must be installed A circuit breaker is not required for 12 24 or 48 VDC rated power supplies For dual DC power supplies Separate circuit breakers must be installed a...

Страница 20: ...it breaker must be installed 100 240VAC rated equipment A 250VAC appropriately rated circuit breaker must be installed A circuit breaker is not required for 48 or 24VDC rated power supplies Separate c...

Страница 21: ...supply terminal block This metal jumper connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during HIPOT testing...

Страница 22: ...wer up of the unit and remain energized until a critical error occurs The proper relay connections are shown in Figure 22 One common application for this output is to signal an alarm if a power failur...

Страница 23: ...Console cable For user reference the console cable pin out is shown in Table 4 RuggedCom RS232 over RJ45 pin out specification Signal Name PC is DTE DB9 Female RJ45 Male DCD Carrier detect 1 2 RxD Rec...

Страница 24: ...able 5 RJ45 Ethernet pinout assignment NOTE RuggedCom does not recommend the use of CAT 5 10 100Base TX communications cabling of any length for critical real time substation automation applications H...

Страница 25: ...e infrastructure required 5 Yes Verify TIA EIA 568 A compliance 5e Yes No action required New installations should be designed with Category 5e components or higher 6 Yes No action required 6 Yes Conn...

Страница 26: ...hen not plugged into a chassis SFP and GBIC optical modules should always be stored in an ESD safe bag or other suitable ESD safe environment free from moisture and stored at proper storage temperatur...

Страница 27: ...ure 27 Locking latch location on GBIC optical modules 2 9 3 SFP Module Removal SFP Modules are removed using the metal bail latch located on the top of the module shown in Figure 28 To remove the SFP...

Страница 28: ...30 W NOTES 1 This is the same power supply for both AC and DC 2 F Denotes fast acting fuse T denotes time delay fuse For continued protection against risk of fire replace only with same type and rati...

Страница 29: ...3x Full Duplex Operation IEEE 802 1D MAC Bridges IEEE 802 1Q VLAN Virtual LAN IEEE 802 1p Priority Levels 3 4 Twisted Pair Port Specifications Parameter Specification Notes Speed 10 100 Mbps Auto neg...

Страница 30: ...assemblies installed in a particular product Optics Order Code Speed Standard Mode Connector Tx nm Cable Type um Tx min dBm Tx max dBm Rx Sensitivity dBm Rx Saturation dBm Typical Distance km Power B...

Страница 31: ...310 9 125 9 5 3 21 3 10 11 5 12 11 0028 1000LX SM LC 1310 9 125 5 0 24 3 25 19 12 11 0025 1000LX SM SC 1310 9 125 10 3 20 3 10 10 12 11 0026 1000LX SM SC 1310 9 125 5 0 20 3 25 15 25 10 0111 1000SX MM...

Страница 32: ...hen determining maximum segment distances 2 All cabling is duplex type unless otherwise specified 3 All optical power numbers are listed as dBm averages 4 These transceivers utilize a distributed feed...

Страница 33: ...C 60255 22 1 IEC Surge 4 kV 2 kV IEC 61000 4 5 Level 4 IEC Fast Transient 2 kV 1 kV IEC 61000 4 4 Level 4 ANSI IEEE Fast Transient 4 kV ANSI IEEE C37 90 1 IEC Radiated RFI Immunity 10 V m IEC 61000 4...

Страница 34: ...he center of the enclosure Ambient Relative Humidity 5 to 95 Non condensing Ambient Storage Temperature 40 to 85 C 3 8 Mechanical Specifications Parameter Value Comments Dimensions 18 29 x 10 17 x 1 7...

Страница 35: ...Technical Specifications Figure 30 RSG2000 Series Mechanical Dimensions RuggedSwitch RSG2100 35 RuggedCom...

Страница 36: ...FR Chapter 1 Subchapter J Compliant IEC EN EN60825 1 1994 A11 1996 A2 2001 Compliant 5 Warranty RuggedCom warrants this product for a period of five 5 years from date of purchase For warranty details...