3 Specifications
3.1 Power Supply Specifications
Power Supply Type
Minimum
Input
Maximum
Input
Fuse
Rating
Maximum Power
Consumption
24 VDC
18 VDC
36 VDC
3.15A(T)
2
48 VDC
36 VDC
72 VDC
3.15A(T)
2
HI (88/300 VDC)
1
HI (120/240 VAC)
1
88 VDC
85 VAC
300 VDC
264 VAC
3.15A(T)
2
3 W
Notes: 1 – This is the same power supply for both AC and DC.
2 – (T) Denotes time-delay fuse
CAUTION:
For continued protection against risk of fire, replace only with same type and rating of
fuse.
3.2 Fiber Optical Port Specifications
Parameter
Specifications
Mode
Multimode
Connector
ST
Typical Dist. (km)
5
Optical Wavelength (nm)
820
Cable Size
Core/Cladding (um)
50/125
62.5/125
Tx Power (dBm)
-13
Rx Sensitivity (dBm)
-33.5
Rx Saturation (dBm)
-11
Typical Budget (dB)
17.5
Notes:
1.
Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
2.
All optical power numbers are listed as dBm averages.
17
©
2006 RuggedCom Inc. All rights reserved
Rev100