![Rugged CCTV SCOUT III Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/rugged-cctv/scout-iii/scout-iii_instruction-manual_1499237027.webp)
IR Dome Camera Instruction Manual
26
8
Vertical range is
not within 90
degree with
large deviation
Fault occurs when the dome
device is in tilt movement. It
may be caused by obstacle
of camera of other object,
which lead to early tilt
movement
Check and adjust the
mechanical
installation
9
Self-test is
normal, but
cannot control
Wrong setting
Set the protocol, baud
rate and address of
dome device
Improper connection of
control cable
Check the circuit
10
Insensitive
control of dome
device
Overload or too long
distance transmission
Add driver
Mostly happen in the
connection
Improper contact of control
cable
Check the circuit
Slip ring is damaged
Replace slip ring
RS-485 protective discharge
arresters broken
Change 485 protective
discharge arresters
11
Call out function
fails
System failure caused by
noise interference
Restart the dome
device
12
Auto action of
dome device
periodically
No transmission auto “call
back” function is set to the
dome device
Called this setting
13
One dome
working well
while the other
does not under
identical
operaion
Something wrong with the
setting or wiring
check the setting and
wiring again