#3. Specification 

 

 

General 

CPU 

32bit RISC Processor (200MIPS)  

Flash Memory 

8MB 

Main Memory 

64MB 

OS  

Embedded LINUX 

Video Channel 

8 Analog Channel (NTSC or PAL) 

Storage Device 

Internal 3.5” IDE HDD 2EA (default  1EA) 

External 2EA for IEEE1394 Interface 

Support Max. 4Tbytes 

Intelligent File System 

Data-loss protection against power failure 

 

Image Compression 

Technology 

Differential Wavelet  

Average File Size  

1~5KB (Standard Quality) 

Image Quality Level 

5 Level 

Image Compression Rate  

20:1~500:1 

Recording Speed 

60 ips/50 ips(NTSC/PAL) 7.5 ips/8ch or 30 ips/2ch 

 

Network 

Browser 

D VR Manager 

Protocol  

TCP/IP, ARP, ICMP, DHCP, FTP, PPPoE

 

Connector 

10/100Mbps Ethernet (RJ-45) 

S/W Upgrade  

Firmware upgrade via Network 

Simultaneous Users  

Monitoring : Max. 5 Users 

Playback : Max. 5 Users 

Security 

Password (User or Administrator Authenticantion)  

Watermarking (Against image forging)  

 

Содержание ELX8-60

Страница 1: ...ELX8 60 Installation Guide v 1 0a...

Страница 2: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 3: ...60 4 Be careful not to drop the ELX8 60 Physical shocks may harm the product In addition be sure the ELX8 60 is secured after installation 5 ELX8 60 is made of metal Therefore you can hurt human being...

Страница 4: ...te controller 17 6 1 Setting remote control DIP switch 17 6 2 Setting ID of ELX8 60 17 6 3 Selecting ELX8 60 18 6 4 Operable range of remote controller 18 6 5 Loading the batteries into remote control...

Страница 5: ...ce with Serial Port 31 11 1 Connecting Text Input Device ATM POS Access Control 31 12 Connecting Configuring Serial Ports for Pan Tilt Zoom 32 12 1 Connecting Serial Port 32 12 1 1 Connecting RS232 32...

Страница 6: ...ninstalling DVR Manager 43 16 4 Configstation 43 16 5 Monitor 44 16 6 Playback 44 APPENDIX 45 1 HDD 46 1 1 Fundamental Notions Terms 46 1 2 Installing HDD 48 1 3 Replacing HDD 60 1 4 Keeping Data 61 1...

Страница 7: ...1 4 9 Ch Mode on CCTV Monitor as well as PC q Maximum 4TB storage capacity IEEE 1394 for external HDD q ATM POS transaction information text recording and search with corresponding video q 4 pairs of...

Страница 8: ...ugged CCTV 2 Supplied Accessories Unpack and check all the items as below 1 ELX8 60 1 2 DC Power Supply 1 110V 220V 3 AC Power Cord 1 4 CD ROM Including DVR Manager 1 5 Remote Controller 1 6 Guide 2 7...

Страница 9: ...EW ELX8 60 Rugged CCTV 2003 08 13 v 1 0 9 3 Description Function ELX8 60 Front 1 LED 2 IEEE1394 connecter 3 Remote controller receiver 4 USB connecter 5 Function buttons 6 Bracket fixing hole for rack...

Страница 10: ...Audio input output connector 11 RS232 connecter 9Pin D Sub 12 Terminal block for RS232 422 485 13 Terminal block for Sensor input 14 Terminal block for Relay output 15 Video output for MONITOR or VCR...

Страница 11: ...CONNECTION 4 Connecting Running ELX8 60 4 1 Connecting camera 1 Set video type NTSC PAL by rear panel s switch 2 Connect CCTV camera to ELX8 60 with BNC cable as shown below Note The video type for a...

Страница 12: ...Connecting Monitor 1 Connect CCTV monitor to ELX8 60 with BNC cable as shown below Note ELX8 60 has two video output ports for Monitor and VCR The output signals from the two ports are same and either...

Страница 13: ...2003 08 13 v 1 0 13 4 4 Supplying Power 1 Connect power cable to ELX8 60 2 Turn on the power switch located on the ELX8 60 rear panel Note Use the plug bracket to secure the power cable if needed Note...

Страница 14: ...menu Use the arrow button s to move within the sub menu list To move to the setting page press the ENTER button To exit the setting page press the EXIT button 3 Setting Page The select ed item is sho...

Страница 15: ...to set word 1 Using number button Enter the related numbers in order of horizontal vertical For example in order to select C press 3 and 2 buttons 2 Using arrow button Select a value using the or butt...

Страница 16: ...AND CONNECTION 16 2003 08 13 v 1 0 Rugged CCTV 3 Function word The following symbols are for executing specific functions 1 2 1 Enter Back Space delete Space Move to left Move to right Previous Code...

Страница 17: ...the remote control DIP switch t o ON 6 2 Setting ID of ELX8 60 When controlling sever al ELX8 60s with one remote controller set Remote Control ID as follows 1 Press the MENU button 2 Select System w...

Страница 18: ...Remote Control ID Up to 16 ELX8 60s can be controlled with a single remote controller 6 3 Selecting ELX8 60 If several ELX8 60s are set with unique ID numbers they can be controlled with one remote c...

Страница 19: ...19 6 5 Loading the batteries into remote controller Remote controller requires two AAA type batteries 1 Remove the battery cover 2 Taking care that the poles are correctly positioned 3 Replace the bat...

Страница 20: ...ELX8 60 INSTALLATION AND CONNECTION 20 2003 08 13 v 1 0 Rugged CCTV 7 ELX8 60 Configuration 7 1 Basic Configuration 7 2 Advanced Configuration...

Страница 21: ...INSTALLATION AND CONNECTION ELX8 60 Rugged CCTV 2003 08 13 v 1 0 21 7 3 External Storage Backup Configuration 7 4 Internet Intranet Configuration...

Страница 22: ...ION 22 2003 08 13 v 1 0 Rugged CCTV 8 ELX8 60 Basic Setting 8 1 Viewing Image After initial start up images from Ch 1 4 are displayed in a quad split screen Note If user password is set a prompt for e...

Страница 23: ...e button and press the EXIT button when finished 8 2 2 Daylight Saving 1 Daylight Saving Time is only activated for time zones that use Daylight Savings If activated press ENTER to enter a new value 2...

Страница 24: ...lect t he value usingthe buttons 3 Press the EXIT button when finished 8 2 7 Apply Date Time Most setting values are applied automatically when exiting from the related menu page But Date Time setting...

Страница 25: ...status When setting up through the Quick Setup menu Quick Setup will be shown When setting up through Normal Rec or Alarm Rec Custom Setup will be shown Note Only when all the 16 channels normal reco...

Страница 26: ...s Custom values can be set manually 1 Select Speed using buttons and press the ENTER button 2 Select a value using the button Press the EXIT button when finished 8 3 5 Quality When Recording Speed Qua...

Страница 27: ...27 9 Connecting and Configuring Sensor 9 1 Connecting Sensor Input To connect a sensor to S1 fix the wire to S1 and G Note Devices connected to the sensor input should have Dry contact The following...

Страница 28: ...ugh the OSD Configuration menu 2 Select the sensor number S1 S2 etc and press the Enter button to configure Use the buttons to select On or Off Press EXIT when finished 3 When activated the Pre Post A...

Страница 29: ...t 10 1 Connecting Relay Out ELX8 60 has total four ports of Relay Out To connect a device to O1 connect the wires to two O1 s Note The rated voltage and current of Relay Out are as follows Do not exce...

Страница 30: ...onized with a sensor input or with motion detection for each of the four time schedules Weekday Day Weekday Night Weekend Day Weekend Night Relays can also be controlled locally by pressing the SEARCH...

Страница 31: ...POS ATM through the RS232 serial port Connect RS232 to 9pin D sub of ELX8 60 and configure the Text sub menu under the System tab Set Serial Setup under the System menu tab to RS232 and Device to Tex...

Страница 32: ...otocols already pre programmed Makes and models not supported can still be controlled using the Transparent Protocol For a list of supported protocols refer to the list on the OSD Configuration menu 1...

Страница 33: ...al Port Configure PTZ serial ports and available modes at System Serial Setup After completing serial setup configure base address and port for each channel under the Camera menu tab When connecting P...

Страница 34: ...Wire Peel off the wiring cover 8 10mm and solder it Wire gage should be AWG 20 26 Inserting removing wire To insert the wire use a screwdriver as shown in the diagr am to the right 13 Connecting USB...

Страница 35: ...connected the disk is recognized automatically as in the following picture To c opy images the process is as follows Set copy range up to 1 minute Select drive Copy press Start Note USB Flash products...

Страница 36: ...lt the local RUGGED CCTV distributor 14 2 Connecting IEEE1394 Device When using FireWire supported external HDD hard drive bays can be connected to 1 port in the front panel or 1 port in the rear pane...

Страница 37: ...l No Size 6Y060L0 60GB 4R060L0 60GB 6Y080L P 0 80GB 4R080L0 80GB 6Y120L P 0 120GB 4R120L0 120GB 6Y160L P 0 160GB 4R160L0 160GB 6Y200P0 200GB DiamondMax Plus 9 7200rpm 6Y250P0 250GB DiamondMax 16 5400r...

Страница 38: ...HDD status is changed to 6 Select Action using button and press EXIT button 7 Select Format using button and press EXIT button 8 Select Apply using button and press EXIT button The HDD status is chan...

Страница 39: ...0 Rugged CCTV 2003 08 13 v 1 0 39 Note 1 Supply power to ELX8 60 after connecting Ethernet cable to protect against electrical damage to ELX8 60 2 Check cable connection status 3 Check LED on ELX8 60...

Страница 40: ...3 Select Network using the buttons and press ENTER 4 Select IP Addr using the buttons and press ENTER 5 Press EXIT button after entering IP address in the dialogue box 6 Select Net Mask using the butt...

Страница 41: ...MB or above VGA 16 MB or above 32 MB or above OS Windows 2000 XP Windows 2000 XP Resolution 1024 X 768 pixels or above 1024 X 768 pixels or above Network 100 Base TX Fast Ethernet 100 Base TX Fast Eth...

Страница 42: ...ect which component s to install and press the Next button 5 Browse and choose a directory if the default directory is not preferred Click the Install button after selecting a directory to install 6 C...

Страница 43: ...v 1 0 43 16 3 Uninstalling DVR Manager 1 Click Windows Start Button 2 Select and Click Uninstall icon to run Uninstall Shield 3 DVR Manager program will be automatically deleted 16 4 Configstation Cli...

Страница 44: ...STALLATION AND CONNECTION 44 2003 08 13 v 1 0 Rugged CCTV 16 5 Monitor Click the related icon and run the DVR ManagerMonitor program 16 6 Playback Click the related icon and run the DVR Manager Playba...

Страница 45: ...APPENDIX ELX8 60 Rugged CCTV 2003 08 13 v 1 0 45 APPENDIX APPENDIX...

Страница 46: ...mary Secondary Each channel can be connected to two devices Mas ter Slave HDD CD ROM However ELX8 60 supports 1 channel interface internally and total two HDDs In order to prevent confusing VFS2 s Pri...

Страница 47: ...nager 2 HDD Type at Disk Manager R Available of recording V Connected and formatted as ELX8 60 s file system If using Add used command it will be changed to R There is no need to reformat F Connected...

Страница 48: ...d command Confirm Removed Used when a removed HDD is still listed ALL DATA WILL BE LOST 1 2 Installing HDD Compatible HDD It is recommended to use the following HDD models with the ELX8 60 If a non re...

Страница 49: ...ollow below process 1 Turn off the power of ELX8 60 2 Check whether the dip switches are set as illustrated below 3 Remove the 6 screws as illustrated below and pull up the cover from the rear part to...

Страница 50: ...Caution for HDD Management 1 Replacing SLAVE HDD of internal 2 HDDs causes permanent data loss in the SLAVE HDD 2 MASTER HDD has all the index of stored data including SLAVE HDD Corruption on MASTER...

Страница 51: ...IX ELX8 60 Rugged CCTV 2003 08 13 v 1 0 51 6 Connect HDD power cable to main PCB ASS Y Secure the HDD with screws 7 Connect HDD cable s connector to HDD as in the following picture 8 Assemble the top...

Страница 52: ...s a HDD that is indicated as F IntA Select it 3 Press the Apply button after selecting action as Add Then F is changed to 4 Press the Apply button after selecting action as Format and setting the size...

Страница 53: ...l be placed at upper list 5 Select a HDD for installing as auxiliary disk 6 Press the Apply button after selecting action as Add Then F is changed to 7 Select a primary disk and press the Apply button...

Страница 54: ...face and has two ports of IEEE1394 ELX8 60 supports upto 4TB storage Note 1 Some IEEE1394 ports may not be recognized by the ELX8 60 Before purchasing consult the local RUGGED CCTV distributor 2 Exter...

Страница 55: ...F Ext Press the Apply button after selecting action as Add Then F is changed to 4 Select a fourth HDD of F Ext Press the Apply button after selecting action as Add Then F is changed to 5 Select a seco...

Страница 56: ...he manual of related device 1 When external HDD RAID is connected to IEEE1394 port Disk Manager runs automatically If not run it manually in Menu Utility Disk Manager 2 Select a second HDD of F Ext Pr...

Страница 57: ...n as Add Then F is changed to Note It is when ExtA is added as primary disk If connecting the device that is used in ELX8 60 type will be indicated as V 3 Select a second HDD of F Ext Press the Apply...

Страница 58: ...D RAID is connected to IEEE1394 port Disk Manager runs automatically If not run it manually in Menu Utility Disk Manager 2 Select a first HDD of F Ext Press the Apply button after selecting action as...

Страница 59: ...APPENDIX ELX8 60 Rugged CCTV 2003 08 13 v 1 0 59 6 Press the EXIT button to shut down Disk Manager...

Страница 60: ...60 is rebooted in specific playback range 2 When image searching per event is impossible 3 When recording is stopped and Disk Manager shows HDD type as X When primary disk is broken When primary disk...

Страница 61: ...the Backup Data menu 5 Set backup range and press the Start button after selecting backup HDD Note 1 Backup HDD should be formatted as FAT32 type 2 Backup data can be replayed with specific S W DVR Ma...

Страница 62: ...mended to use external HDD instead of internal HDD Namely connect only one external HDD and then keep it after data is full Note The preserved HDD s data is possible to replaying only when it is conne...

Страница 63: ...LX8 60 Remote Management Program Acrobat Reader V ersion 5 1 Preparation To read manual of CD ROM disc Adobe Acrobat 5 0 should be installed in client s PC Note If Adobe Acrobat Reader is not installe...

Страница 64: ...tection against power failure Image Compression Technology Differential Wavelet Average File Size 1 5KB Standard Quality Image Quality Level 5 Level Image Compression Rate 20 1 500 1 Recording Speed 6...

Страница 65: ...of condensation Storage Humidity 93 below free of condensation Data Backup Expansion Copy HDD Expandable Data Backup IEEE1394 Analogue VCR VHS Video output for VCR Backup Reminder Daily Weekly Monthly...

Страница 66: ...tection or Sensor input Alarm Data Preservation Alarm triggered Video Data Preservation Alarm Log Log search Log monitoring via OSD Network Pre Post Alarm Pre 1 10 seconds Post 1 60 seconds Schedule R...

Страница 67: ...APPENDIX ELX8 60 Rugged CCTV 2003 08 13 v 1 0 67 Mechanical Dimension W D H 306 x 280 x 67 mm Weight 3 5Kg With one HDD...

Страница 68: ...ELX8 60 APPENDIX 68 2003 08 13 v 1 0 Rugged CCTV...

Страница 69: ...ELX8 60 Rugged CCTV 2003 08 13 v 1 0 69 Rugged CCTV 5327 Cedar Creek Dr Kemp Texas 75143 Tel 866 301 2288 Fax 903 498 8989 Technical Support 1 866 301 CCTV URL www rugged cctv com E mail sales rugged...

Отзывы: