ELX4 -60
BASIC CONFIGURATION
14
2003.05.21 (v 1.0)
Rugged CCTV
3.5. Viewing an alarm triggered channel
- When an alarm is triggered, the related channel will pop-up full screen automatically.
- Set ‘Alarm Pop -up Screen’ function to “On ” in “Configuration” under the “Monitor” tab , and set the
display duration in “Pop-up Hold (sec)”
- If more than one channel is triggered by an alarm, the related channels will be displayed simultaneously
in a split -screen. In order to move current screen, press any button.
3.6. Viewing images with Digital Zoom
- In Single Full Screen mode, live and recorded images can be expanded using the Digital Zoom feature.
- To enable the digital zoom, press the [ZOOM] button.
- Digital Zoom will expand the image to twice its normal size.
- Default location of the digital zoom is in the center of screen. The zoom box can be moved each 10
th
step to left and right and 4
t h
step up and down.
- To move the zoom box, use the [Arrow] button.
- To cancel the zoom box, press the [ZOOM] button once more.
3.7. Viewing with connected PTZ
- Pan/Tilt/Zoom (PTZ) devices can be controlled through the ELX4 -60
when a PTZ device is connected and properly configured under “Serial
Setup.”
- While in Monitor mode, press the [SELECT] button.
- Channel selection icon will be displayed.
- Move the icon to the channel t o contr ol with the [Arrow] button.
- Press the [MENU] button.
- PTZ menu (Pan/Tilt, Zoom/Focus, Load Preset, Save Preset) will appear.
- Press the [ENTER] button after selecting the desired function.