FX4 TECHNICAL DATA FOR 50 HZ ELECTRIC AIR HEATERS
NOTES:
1. Minimum conductor size for 30˚C (86˚F) ambient. Derate conductor for ambient temperature. Use minimum 90˚C (194˚F) insulation.
2. Heater is functioning normally if at rated voltage the amp draw is within 10% of the value in this table.
3. Operation at lower voltages will result in reduced heat output and amp draw
4. Add “T” to model number when adding a built-in thermostat
MODEL
VOLT-
AGE
NOMINAL
WATTAGE
PHASE
MAX. MOTOR
NAMEPLATE
CURRENT
HEATER
WATTAGE
TOTAL
CURRENT
MIN. CIRCUIT
AMPACITY
SUPPLY
WIRE SIZE
MAXIMUM
FUSE SIZE
TEMPERATURE
RISE
CORE
PART
NUMBER
CONTACTOR
PART
NUMBER
(V)
(kW)
(A)
(W)
(A)
(A)
(AWG)
(A)
°F
°C
FX4-220150-025
220
2.5
1
2.0
2,270
11.4
14.3
14
15
19.7 11.0 10410
3618
FX4-220150-042
220
4.2
1
2.0
3,950
19.1
23.9
10
25
33.2 18.4 10411
3618
FX4-220150-063
220
6.3
1
2.0
6,050
28.6
35.8
8
40
28.4 15.8 10412
3618
FX4-220150-084
220
8.4
1
2.0
8,140
38.2
47.8
6
50
37.9 21.1 10413
3618
FX4-220150-126
220
12.6
1
2.0
12,100
57.3
71.6
4
80
27.5 15.3 10424
3618
FX4-380350-025
380
2.5
3
0.7
2,260
3.8
4.8
14
15
19.7 11.0 10410
3618
FX4-380350-042
380
4.2
3
0.7
3,930
6.4
8.0
14
15
33.2 18.4 10411
3618
FX4-380350-063
380
6.3
3
0.7
6,020
9.6
12.0
14
15
28.4 15.8 10412
3618
FX4-380350-084
380
8.4
3
0.7
8,100
12.8
16.0
12
20
37.9 21.1 10413
3618
FX4-380350-125
380
12.5
3
0.7
12,030
19.0
23.8
10
25
27.2 15.1 10424
3618
FX4-380350-167
380
16.7
3
0.7
16,220
25.4
31.8
8
35
36.4 20.2 10425
3618
FX4-380350-209
380
20.9
3
1.0
20,230
31.8
39.8
8
40
22.0 12.2 10429
3618
FX4-415350-037
415
3.7
3
0.7
3,510
5.1
6.4
14
15
29.2 16.2 10415
3618
FX4-415350-075
415
7.5
3
0.7
7,240
10.4
13.0
14
15
33.9 18.8 10417
3618
FX4-415350-149
415
14.9
3
0.7
14,510
20.7
25.9
10
30
32.5 18.0 10218
3618
FX4-415350-224
415
22.4
3
1.0
21,820
31.2
39.0
8
40
23.6 13.1 10431
3618
®
FIGURE 8