PA R T S   L I S T

F O R C E D   A I R   E L E C T R I C   H E AT E R S

PART NUMBERS

Please have model and serial number 

available before calling.

ITEM

2.5 - 10 kW

12.5 - 20 kW

20.9 - 35 kW

Description

1

Core

2

3773

3774

3775

Panel, Bottom

3

3776

3777

3778

Panel, Left Side

4

4075

4076

4077

Louver Kit, c/w Screws

5

3770

3771

3772

Panel, Top

6

3779

3780

3781

Panel, Right Side

7

3782

3783

3784

Fan Shroud

8

2.5 - 5 kW: 4022 

6.3 - 10 kW: 4023

4024

4025

Fan

9

4078

4079

4080

Fan Guard Kit

10

208/240V 60 HZ 1 PH: 1979/10388 

220V 50 HZ 1 PH: 1979/10388 

480V 60 HZ 1 PH: 9896 

208/240/480V 60 HZ 3 PH: 1699/10387 

380/415V 50HZ 3 PH: 1699

240/480V 60 HZ 3 PH: 

1699 

380/415V 50 HZ 3 PH: 

1699 

600V 60 HZ 3 PH: 

2433/10672

Motor, Explosion-Proof

11

3789

3789

3789

Bracket, Motor Mount Right

12

3785

3786

3787

Channel, Motor Mount

13

3788

3788

3788

Bracket, Motor Mount Left

14

3737/4590

3737/4590

3737/4590

Coupling, Motor

15

3811

3812

3813

Conduit, Motor

16

4983

4983

4983

Enclosure, Conduit Junction

17

208/240V 60 HZ 1 PH: 3813 

220V 50 HZ 1 PH: 3813 

480V 60 HZ 1 PH: 3813 

ALL 3 PH: 3813

3813

Conduit, Control Enclosure

18

3810

3810

3810

Conduit, Element Enclosure

19

3793

3793

3793

Enclosure, Element

20

3510

3510

3510

Cover, Element Enclosure

21

3790

3790

3790

Panel, Element Enclosure guard

22

4983

4983

4983

Enclosure, Thermostat

23

5032

5032

5032

Thermostat, Built-in Kit

24

3524

3525

3526

Enclosure, Control

25

10557

10557

10557

Contactor

26

10556

10556

10556

Transformer

27

3809

3809

3809

Bracket, Printed Cuircuit Board

28

1876

1876

1876

Terminal, 6-14 ga. Screw Lug

29

3519

3519

3519

Fuse, Buss MDQ-1/4 Amp

30

3514

3514

3514

Printed Circuit Board Assembly

31

3516

3516

3516

Cover, Control Enclosure

32

4082

4082

4082

Temperature High-Limit Kit

33

3816

3816

3816

Bus-Bar, Straight

34

3817

3817

3817

Bus-Bar, Small Curved

35

3818

3818

3818

Bus-Bar, Large Curved

Содержание FX4 Series

Страница 1: ...Temperature Code T3B 165 C 329 F 50 Hz 60 Hz Models For details of hazardous locations with potential for explosion refer to the Canadian Electrical Code Part 1 Section 18 or National Electrical Code articles 500 516 WARNING Read all important information notices Ruffneck and VacuCore are registered trademarks of Thermon Heating Systems Inc Copyright 2018 All rights reserved Part No 5031 Rev 15 06...

Страница 2: ...se rating and type are on printed circuit board Correct fuse must be in the active fuse clip It is recommended that a spare fuse be stored in the spare fuse clip Check all explosion proof conduits Replace damaged conduits All threaded conduit connections must have a minimum 5 turns engagement Straight threaded conduit must protrude a minimum of 1 16 1 6mm inside enclosures Taper threaded connectio...

Страница 3: ...ght position Refer to the Installation Mechanical section for details 12 Heater must be kept clean When operating in a dirty environment regularly clean the finned tubes fan and fan guard Follow the recommended maintenance procedures Refer to the Heater Maintenance Checklist section for details 13 The heater core is vacuum charged and contains propylene glycol If any fluid leakage occurs from the ...

Страница 4: ... that may impede the heater s air inlet or discharge 2 The air discharge is directed into open areas and not at occupants 3 The air discharge is not directed at a thermostat 4 The air discharge is directed across areas of heat loss such as doors and windows see Figure 1 5 The air discharge is directed along and at a slight angle toward exterior walls see Figure 1 6 If equipment freeze protection i...

Страница 5: ...ode fuse size shall be 125 of the line current or next size larger F I E L D W I R I N G 1 The supply conductors ground conductor and room thermostat conductors see point 2 page 4 all pass through the 1 NPT opening see Figure 4 and are to be wired into the control enclosure see Figure 5 2 Heater may be supplied with a factory installed built in room thermostat On heaters not supplied with this opt...

Страница 6: ...0 6 3 1 2 0 6 050 28 6 35 8 8 40 28 4 15 8 10412 3618 FX4 220150 084 220 8 4 1 2 0 8 140 38 2 47 8 6 50 37 9 21 1 10413 3618 FX4 220150 126 220 12 6 1 2 0 12 100 57 3 71 6 4 80 27 5 15 3 10424 3618 FX4 380350 025 380 2 5 3 0 7 2 260 3 8 4 8 14 15 19 7 11 0 10410 3618 FX4 380350 042 380 4 2 3 0 7 3 930 6 4 8 0 14 15 33 2 18 4 10411 3618 FX4 380350 063 380 6 3 3 0 7 6 020 9 6 12 0 14 15 28 4 15 8 10...

Страница 7: ...40 27 9 15 5 10412 3618 FX4 240360 075 240 7 5 3 1 4 7 200 18 0 22 5 10 25 27 9 15 5 10412 3618 FX4 480160 075 480 7 5 1 1 3 7 200 15 6 19 5 12 20 27 9 15 5 10416 3618 FX4 480360 075 480 7 5 3 0 7 7 200 9 0 11 3 14 15 27 9 15 5 10416 3618 FX4 600360 075 600 7 5 3 0 6 7 200 7 2 9 0 14 15 27 9 15 5 10420 3618 FX4 208160 100 208 10 1 2 7 9 690 48 1 60 1 4 70 37 2 20 6 10409 3619 FX4 208360 100 208 10...

Страница 8: ... will not enter Mounting Holes Two 9 16 in 14 3 mm diameter holes at top of heater Heating Elements Three long life low watt density high grade metal sheathed elements Temperature High Limit Automatic reset type snap action bimetal open on temperature rise Rated 100 000 cycles at 10 amps handles 0 128 amps Control Circuit 120 Volts 0 128 amps 15VA Grounded Optional Built in Thermostat Explosion pr...

Страница 9: ...ting Holes Two 9 16 in 14 3 mm diameter holes at top of heater Heating Elements Three long life low watt density high grade metal sheathed elements Temperature High Limit Automatic reset type snap action bimetal open on temperature rise Rated 100 000 cycles at 10 amps handles 0 130 amps Control Circuit 115 Volts 0 130 amps 15VA Grounded Optional Built in Thermostat Explosion proof 2 C to 28 C 36 F...

Страница 10: ...SEMBLY DIAGRAM HIGH LIMIT ASSEMBLY DIAGRAM Optional built in thermostat replaces item 16 1 4 22 23 24 5 6 7 8 9 10 11 12 13 14 15 16 17 2 9 19 20 21 25 26 30 31 32 27 28 29 3 18 33 BUS BAR CONFIGURATION ALL 1 PHASE MODELS BUS BAR CONFIGURATION ALL 3 PHASE 60 HERTZ 3 PHASE 50 HERTZ 415 VOLT MODEL BUS BAR CONFIGURATION 3 PHASE 380 VOLT 50 HERTZ MODELS ONLY ...

Страница 11: ...788 Bracket Motor Mount Left 14 3737 4590 3737 4590 3737 4590 Coupling Motor 15 3811 3812 3813 Conduit Motor 16 4983 4983 4983 Enclosure Conduit Junction 17 208 240V 60 HZ 1 PH 3813 220V 50 HZ 1 PH 3813 480V 60 HZ 1 PH 3813 ALL 3 PH 3813 3813 Conduit Control Enclosure 18 3810 3810 3810 Conduit Element Enclosure 19 3793 3793 3793 Enclosure Element 20 3510 3510 3510 Cover Element Enclosure 21 3790 3...

Страница 12: ...ring into the thermowell without damaging the insulating tube Secure in place with the cotter pin see Figure 12 MOTOR FAN FAN GUARD 1 Remove bolts holding the motor to the motor mount On units with a built in thermostat remove the bolts on the back of the thermostat enclosure 2 Remove conduit 1 located between motor junction box and control enclosure by turning it in the direction illustrated see ...

Страница 13: ... the same rating T R A N S F O R M E R 1 Replace with a factory supplied transformer of the same rating 2 On the new transformer select primary wires to match heater voltage Ensure that the correct transformer secondary lead is grounded see Figure 8 Individually terminate all unused wires using closed end connectors F U S E Replace fuse with one of the same type and rating as indicated on P C Boar...

Страница 14: ... 14 NOTES ...

Страница 15: ... 15 NOTES ...

Страница 16: ...y but not so as to limit the generality of the foregoing includes physical chemical or mechanical abuse accident improper installation of the product improper storage and handling of the product improper application or the misalignment of parts No warranty applies to paint finishes except for manufacturing defects apparent within 30 days from the date of installation The Company neither assumes no...

Отзывы: