Safety spacing front-opening devices (1-ceramic class pane)
The safety spacing from combu
stible materials must be maintained in the system’s heat-radiation zone.
If Z > than the value cited in the table, Y is reduced. If Z ≤ than cited in the table, the combustible
components must be insulated by the spacing Y.
*With mantle for hot air
The safety spacing may be halved if a radiation shield ventilated on both sides is installed at a distance
of ≥ 2 cm.
Appliance
X
[cm]
Y
[cm]
Z
[cm]
Violino 45x60
125
63 /56*
33
Violino 45x80
150
80
36
Violino 55x73
130
48
26
Violino 55x98
150
55
35
Violino 65x87
170
75
28