Flex-Line
Installation manual
__________________________________________________________________________________
20
Fire-resistant hot air systems
Hot air cross sections
The cross sections of hot air openings in hot air systems may not be closable and the cross section may
not undercut the specification. The hot air openings must be optimally designed in terms of circulating
air to create as little resistance as possible.
For appliances with a hot-air mantle, the connecting supports must be connected to the hot-air grille by
a flexible aluminium hose. Insulate the connecting piece with 3 cm mineral wool. If the supports for the
mantle have not been fed to the hot air grille with flexible aluminium hose or the connecting piece is not
insulated, the hot air cross section must be used by the appliance without a mantel. The hot air inlet
does not have to be connected to the appliance. The cross sections in the cavity may then not exceed
700 cm
2
, however.
Venting the cavity
Aluminium flexible tubing
Connecting support device
Appliance including mantle
Front-opening appliances
* Cavity ventilation
Appliance
Including mantle
Excluding mantle
Inlet
[cm2]
Outlet
[cm2]
Inlet
[cm2]
Outlet
[cm2]
Violino 45x60
350
350+ 175*
600
600
Violino 45x80
350
350 + 175*
800
800
Violino 55x73
700
700 + 175*
730
730
Violino 55x98
700
700 + 175*
980
980
Violino 65x87
700
700 + 175*
1000
1200
RIII 45x56x46
-
-
350
350
RIII 45x56x60
-
-
350
350
RIII 45x56x80
-
-
350
350
RIII 45x80x46
-
-
350
350
RIII 45x100x46
700
700 + 175*
1000
1000
RIII 55x100x46
700
700 + 175*
1000
1000