![ruegg Flex-Line series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/ruegg/flex-line-series/flex-line-series_installation-manual_1499072023.webp)
Flex-Line
Installation manual
__________________________________________________________________________________
23
23
If the thermal insulation with Silca 250KM or equivalent according to application guidelines created by
the manufacturer is sufficient a thickness of 3 cm and can be dispensed with a concrete base with
combustible environment.
Floor covering
If the appliances are integrated directly into the floor in the heat-radiation area of the pane, a simple
precoated board is not sufficient. The floor in the heat-radiation area of the panel, based on the value X
in the table, must not be of flammable construction.
*Normal precoat based on country-specific regulations
** No specific information from the fire safety test
Appliance
X < 30 cm
Kick plate to the finished floor
Y > 30 cm
Kick plate to the finished floor
Distance from non-combustible
floor
[cm]
Distance from non-combustible floor
[cm]
Violino 45x60
80
0*
Violino 45x80
80
0*
Violino 55x73
80
0*
Violino 55x98
80
0*
Violino 65x87
87
0*
RIII 45x56x46
**
0*
RIII 45x56x60
**
0*
RIII 45x56x80
**
0*
RIII 45x80x46
**
0*
RIII 45x100x46
**
0*
RIII 55x100x46
**
0*
Not flammable
Combustible floor
X
Y
Содержание Flex-Line series
Страница 1: ...Flex Line INSTALLATION MANUAL...