Preparing your PC for ZoneDirector 5000 
Setup

On your Admin PC, open the Network Connections (or Network and Dial-up 

1. 

Connections) control panel according to how your Start menu is set up:

Start > Settings > Network Connections

• 

Start > Control Panel > Network and Sharing Center > Change Adapter 

• 

Settings

NOTE: This procedure assumes Windows 7 as the operating system. Procedures 

 

L

for other OS’s are similar.

When the Network Connections windows appears, right click the icon for “Local 

2. 

Area Connection“ and select Properties.
When the Local Area Connection Properties dialog box appears, select Internet 

3. 

Protocol Version 4 (TCP/IPv4) from the scrolling list and click Properties. The TCP/
IP Properties dialog box appears.

NOTE: Write down all of the currently active settings so you can restore your 

 

L

computer to its current configuration later (when this process is complete).

Select 

4. 

Use the following IP address

 (if it’s not already active) and make the 

following entries:

IP Address

• 

: 192.168.0.22 (

or any address in the 192.168.0.x network other than 

192.168.0.2, in use by the ZoneDirector 5000)

Subnet mask

• 

: 255.255.255.0

Default gateway

• 

: 192.168.0.2

Leave the 

5. 

Preferred DNS Server

 and 

Alternate DNS Server

 fields empty.

Click 

6. 

OK

 to save your changes and exit first the TCP/IP Properties dialog box, then 

the Local Area Connection Properties dialog box. Your changes are put into effect 
immediately.

Содержание ZoneDirector 5000

Страница 1: ...Ruckus WirelessTM ZoneDirectorTM 5000 Getting Started Guide Part Number 800 70310 001 Rev F Published June 2013 www ruckuswireless com...

Страница 2: ...e Notes are available at http support ruckuswireless com documents User Guides are available at http support ruckuswireless com documents Software Upgrades are available at http support ruckuswireless...

Страница 3: ...cription below 2 RJ45 serial port COM2 serial B 3 USB port not used 4 Front bezel lock Front panel features 1 Number Description 1 ESD ground strap attachment 2 Hard drive bays not used 3 Control pane...

Страница 4: ...status LED 4 Fan status LED 5 Critical alarm not used 6 MJR alarm LED not used 7 NMI pin hole button factory reset button 8 Chassis ID button 9 NIC1 NIC2 activity LED 10 HDD activity LED not used 11 P...

Страница 5: ...Video connector not used 8 USB 0 and 1 1 on top 9 USB 2 and 3 3 on top 10 GbE NIC 1 connector 11 GbE NIC 2 connector 12 Two ground studs used for DC input system Rear panel features 1 2 3 4 5 6 7 8 9...

Страница 6: ...rver rack Unpacking the Rack Mount Kit Unpack your rack mount kit and identify each item Package Contents A complete rack mount installation kit includes all of the items listed below NOTE This kit in...

Страница 7: ...de Rails into the Inner and Outer Parts Extend the inner rail see 1 in Figure 2 until it locks 1 Press down the spring safety lock see 2 in Figure 2 to release the inner rail 2 Remove the inner rail f...

Страница 8: ...the rack The right rail assembly is identified with a BLUE sticker and the left rail assembly is identified with a GREEN sticker Attach the outer rail slides to the rack posts using two 8 32 x 1 2 scr...

Страница 9: ...the inner rails onto the hex head shoulder screws and then slide the inner rails forward Figure 5 Installing the inner rails Step 5 Fasten the Inner Rails to the Server Secure the inner rails with one...

Страница 10: ...semblies 1 attached to the rack Engage the matching rails and then slide the server chassis into the rack until the 2 two spring safety locks snap into position Press down the two spring safety locks...

Страница 11: ...other end of the power cable s to an electrical outlet 2 Connect one end of an Ethernet cable to one of the RJ45 GbE ports on the rear 3 panel of the ZoneDirector 5000 and connect the other end to an...

Страница 12: ...r electrical shock and fire hazard insure the DC L L wiring to the DC input connectors has adequate circuit protection in accordance with local electrical codes When looking at the DC input connector...

Страница 13: ...Maximum 75Vdc DC Input Current Maximum 13A 38Vdc Grounding the rack installation To avoid the potential for an electrical shock L L hazard for AC power you must include a third wire safety ground con...

Страница 14: ...ernet 3 Protocol Version 4 TCP IPv4 from the scrolling list and click Properties The TCP IP Properties dialog box appears NOTE Write down all of the currently active settings so you can restore your L...

Страница 15: ...Mesh capability at this time Once you have completed the Setup Wizard ZoneDirector is ready to begin 4 controlling your ZoneFlex WLAN s For more detailed configuration information see the ZoneDirector...

Страница 16: ...e handle sliding the PSU all the way out of the rear of the 3 machine Insert the new PSU into the slot and holding the green safety lock slide the PSU 4 into the slot until it locks in place The PSU s...

Страница 17: ...hassis Open the front chassis cover of the ZoneDirector 5000 It may be necessary to 1 extend the ZoneDirector into a maintenance position Identify the faulty fan Each fan has a service required LED th...

Страница 18: ...n a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try...

Отзывы: