Ruckus ICX 7650 Switch Hardware Installation Guide
41
Part Number: 53-1005301-01
DRAFT: BROCADE CONFIDENTIAL
Monitoring the Device
•
•
•
•
•
LED activity interpretation
System activity and status can be determined through the activity of the LEDs on the switch.
There are three possible LED states: off (no light), a steady light, and a flashing light. Flashing lights may be slow, fast, or flickering. The
LED colors are either green or amber.
Sometimes, the LEDs flash either of the colors during boot, POST, or other diagnostic tests. This is normal; it does not indicate a problem
unless the LEDs do not indicate a healthy state after all boot processes and diagnostic tests are complete.
Ruckus ICX 7650 port-side LEDs
The Ruckus ICX 7650-48ZP has the following LEDs on the front panel:
•
Two management port status LEDs (green) for speed and link/activity
•
Two power supply unit (PSU) bicolor status LEDs (green and amber) labeled PWR and PWR2
•
One SYS (system) bicolor status LED (green and amber)
•
One DIAG (diagnostic) bicolor status LED (green and amber)
•
One MSTR (stacking configuration) bicolor status LED (green and amber)
•
One CLD (cloud management) bicolor status LED (green and amber)
•
One UPDATE (software update) bicolor status LED (green and amber)
•
Five status mode LEDs (green) selected by pressing the status mode button:
•
STAT — port LEDs indicate link and traffic activity.
•
SPD — port LEDs indicate the link speed.
•
ID — port LEDs indicate the stack unit ID when the switch is in stacking mode, or the PE ID when in SPX mode.
•
USB — indicates files are being copied to a USB drive connected to the USB port.
•
PoE — port LEDs indicate the PoE status.
•
48 bicolor (green and amber) status LEDs for ports 1-48. The LED indication is dependent on the mode set by the status mode
button.
4x10 GbE module LEDs:
•
Four 1/10 GbE SFP+ port bicolor status LEDs (green for 10 GbE and amber for 1 GbE) which indicate 1 GbE or 10 GbE mode
of operation.