background image

        VS-2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER

’S MANUAL Ver.A3   

                                                                                                                                                                                                                             

 

214 

 

Note: 

If Vlan group include cpu port. The member of this group can management this vdsl2 Ipdslam. 

 

 

 

 

 

Select Untag or Tag Setup. Unless the device (computer or switch) which connect to port 1 or port 10 can support Tagging VLAN, 

otherwise select Untag. 

Содержание VS-2400S

Страница 1: ...2 2 2 M M Ma a an n na a ag g ge e ed d d I I IP P P D D DS S SL L LA A AM M M w w wi i it t th h h P P PO O OT T TS S S s s sp p pl l li i it t tt t te e er r r V V VS S S 2 2 24 4 40 0 00 0 0S S S U...

Страница 2: ...ditions In the interest of improving internal design operational function and or reliability RubyTech reserves the right to make changes to the products described in this document without notice RubyT...

Страница 3: ...n the power cord DO NOT install nor use your device during a thunderstorm There may be a remote risk of electric shock from lightning DO NOT expose your device to dampness dust or corrosive liquids DO...

Страница 4: ...on HDTV and interactive gaming VDSL2 enables operators and carriers to gradually flexibly and cost efficiently upgrade existing xDSL infrastructure ITU T G 993 2 VDSL2 is an enhancement to G 993 1 VDS...

Страница 5: ...uch as hotels campus hospitals and sscom The VS 2400S provides the important features necessary for robust networks Key features and benefits Jumbo packet up to 9k bytes In computer networking jumbo f...

Страница 6: ...ce feature provides four internal queues to support four different classifications of traffic High priority packet streams experience less delay inside the switch which supports lower latency for cert...

Страница 7: ...it too many broadcast multicast unknown unicast flooding in the network broadcast multicast storm control is used to restrict excess traffic Threshold values are available to control the rate limit fo...

Страница 8: ...ol by Telnet and Web based Management easy to use configuration and ongoing monitoring This software is embedded in the switch and delivers remote intuitive management of the switch and connected NIC...

Страница 9: ...at yields the same bit error rate BER The BER equivalent noise for a biased Gaussian noise is simply the amplified version of the underlying Gaussian noise source The amplification factor is derived f...

Страница 10: ...ation 16 1 1 Check list 16 1 2 Package Contents 16 1 3 Product Outward 17 1 4 Key Features Benefits 18 1 5 Product Specifications 22 Chapter 2 General Description 25 2 1 Hardware Description 25 2 2 Fr...

Страница 11: ...tion Notice 37 4 0 1 0 Command Line Editing 38 4 0 1 1 Command Help 39 4 0 1 2 Upgrade firmware via console command line 39 4 0 1 3 Reset system to default via console command line 40 4 0 2 System Com...

Страница 12: ...6 Reboot switch 96 4 0 6 0 Reset to Default 96 4 0 6 1 Restart 96 4 0 7 TFTP Function 96 4 0 7 0 TFTP Firmware Update 96 4 0 7 1 Restore Configure File 97 4 0 7 2 Backup Configure File 97 4 0 8 Access...

Страница 13: ...18 4 2 3 3 VDSL Port Status 119 4 2 4 SNMP Configuration 120 4 2 4 0 System Options 120 4 2 4 1 Community strings 121 4 2 4 2 Trap Manager 121 4 2 4 3 SNMPv3 Group 122 4 2 4 4 SNMPv3 View 123 4 2 4 5...

Страница 14: ...4 3 0 2 QinQ VLAN 144 4 3 1 Forwarding and Filtering 147 4 3 1 0 Dynamic MAC Address 148 4 3 1 1 Static MAC Table 149 4 3 1 2 MAC Filtering 151 4 3 2 IGMP Snooping 152 4 3 3 Spanning Tree 154 4 3 3 0...

Страница 15: ...port Configuration 186 4 5 2 2 Misc Configuration 187 4 6 QoS 189 4 6 0 QoS Configuration 189 4 6 1 Per Port Configuration 190 4 6 2 ToS DSCP Configuration 192 4 7 Monitoring 196 4 7 0 Port Status 196...

Страница 16: ...ith POTS splitter USER S MANUAL Ver A3 15 Appendix B Example of VLAN Setting 212 Example 1 212 Example 2 216 Example 3 218 Appendix C Compliance and Safety Information 221 Warranty 225 Chinese SJ T 11...

Страница 17: ...Power Cord 4 A package contains two Rack Mounting Brackets and screws 5 4 x Rubber feet 6 1 x Console Cable RJ45 to D sub 9 pin 7 2 x RJ21 Cable Notes 1 Please inform your dealer immediately for any m...

Страница 18: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 17 1 3 Product Outward...

Страница 19: ...Supports Port Security with MAC address filtering Supports Port Based VLAN Protocol Based VLAN and VLAN Mapping Supports IEEE 802 1d STP IEEE802 1w RSTP IEEE 802 1s MSTP Supports DHCP Client Relay Op...

Страница 20: ...2 source filtering Flexible per port VLAN classification option supports port based VLAN domain and 802 1Q VLAN domain simultaneously Supports Independent VLAN Learning IVL and Shared VLAN Learning S...

Страница 21: ...pecify Filtering untagged packets or VLAN tagged packets Filtering packets received on non ingress VLAN member ports Supports insertion of 2nd tag with different TPID to VLAN tagged packets Port based...

Страница 22: ...r 2 packet classification result may be used to define packet priority Priority adjustment based on per port profile and per VLAN property Priority of a packet can be upgraded or downgraded based on s...

Страница 23: ...97 1 standards Hardware Interface 2 x Copper Fiber combo giga port 1 x RJ 21 connector for 24 x VDSL2 ports connection 1 x RJ 21 connector for 24 x POTS ports connection 1 x console port RJ 45 115200b...

Страница 24: ...urity L2 Frame Filtering by MAC Addresses L3 Frame Filtering by IP Addresses protocol ID and TCP UDP DHCP and ARP Broadcasting Frames Filtering Support Secured Forwarding Management Local Management R...

Страница 25: ...R S MANUAL Ver A3 24 Dimensions 435mm x 260mm x 67mm 17 12 x 10 24 x 2 63 Regulatory Compliance CE FCC Class B VCCI EN60950 Notes 1 Features and specifications in this manual are subject to change wit...

Страница 26: ...tion This section describes the important parts of the IP DSLAM It features the front and rear panel drawings LEDs connectors and IP DSLAM 2 2 Front Panel The following figure shows the front panel Fi...

Страница 27: ...erminal emulation program such as Hyperterminal and Teraterm 115200 8 None 1 None GE1 GE2 For connecting Gigabit Ethernet VS 2400S provides Gigabit Ethernet combo interfaces TP and SPF TP 10 100 1000...

Страница 28: ...rt GIGA Port supports RJ 45 or SFP Interface auto link function You can use RJ 45 interface or SFP Interface Figure 2 2 Note Please make sure fiber connection has ready and the IP DSLAM will be auto s...

Страница 29: ...nd upgrade electro optical communications networks The typical SFP transceiver is a plug in module that supports hot plugging it can be removed and replaced without turning off the system The devices...

Страница 30: ...1000 Link ACT Active LEDs Steady Giga port indicates that communications have been set 10 100 1000 Mbps Each port on the IP DSLAM is assigned an LED light for 100 or 1000 Base TX connecting Green Blin...

Страница 31: ...he reset buttons allows users to reboot the VDSL2 IP DSLAM or load the default settings Press and hold for 1 5 seconds Reboot the IP DSLAM Press over 5 seconds Load the default settings 2 6 AC Power S...

Страница 32: ...2 Black P23 10 White P15 18 Red P7 27 Blue 35 Green 43 Blue 3 Red P22 11 White P14 19 Red P6 28 Gray 36 Orange 44 Orange 4 Red P21 12 White P13 20 Red P5 29 Brown 37 Blue 45 Green 5 Red P20 13 White...

Страница 33: ...ts sufficient physical space and proximity to other network devices that are to be connected Verify the following installation requirements Power requirements AC 100V to 240 V at 50 to 60 Hz The IP DS...

Страница 34: ...must run at full duplex but the attached device does not support auto negotiation then you should upgrade this device to a newer version that supports auto negotiation Use any of the GbE1 GbE2 ports t...

Страница 35: ...and profile to Annex A 17a and please enter the management of VC 450RT and set the tone mode as A43 from Profile Config Band Plan is Annex A If the user would like to connect with the VC 450RT for Ann...

Страница 36: ...duct with the local serial console port If one of the Ethernet port is not in use you can disable it that procedure is to connect a notebook computer to the RS 232 port then boot operating systems suc...

Страница 37: ...Connects PC with the IP DSLAM you will find login manual window on the screen then enter Login name admin password admin 4 Setting IP Address by Console Port When you are going to login a IP DSLAM th...

Страница 38: ...have to re configure the IP address subnet mask and default gateway The following show how to configure the IP address of a IP DSLAM First login with the console port Username admin Password admin Sec...

Страница 39: ...oves the cursor forward one character Ctrl K Deletes from the cursor to the end of the command line Ctrl N Enters the next command line in the command history Ctrl P Enters the previous command line i...

Страница 40: ...r Tab Switch config copy tftp running config You do not need to type in the entire commands you only need to type in enough characters for the CLI to recognize the command as unique The following exa...

Страница 41: ...r to the configuration mode 12 At the CLI command type the command copy tftp firmware ip addr remote file to upgrade the firmware ip addr specifies the IP address of the TFTP server remote file specif...

Страница 42: ...gs at next boot time clear arp ip addr Clear entries in the ARP cache Parameters ip addr specifies the IP address to be cleared If no IP address is entered the entire ARP cache is cleared show arp Sho...

Страница 43: ...ic Configuration 4 0 3 0 Port Configuration and Status port state on off port list Turn the port state on or off Parameters port list specifies the ports to be turn on or off If not entered all ports...

Страница 44: ...te ingress egress 0 8000 port list Set port effective ingress or egress rate Parameters 0 8000 specifies the ingress or egress rate 0 8000 port list specifies the ports to be set If not entered all po...

Страница 45: ...ort forward jumbo frame packet Parameters port list specifies the ports to be set If not entered all ports are set port interval 0 3600 While flooding CPU port at the speed of 4MB s or larger system w...

Страница 46: ...ing a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically A station can belong to more than one VLAN group VLAN prevent...

Страница 47: ...own in the following figure the switch administrator configured port 1 2 as VLAN 1 and port 3 4 as VLAN 2 The packets received from port 1 can only be forwarded to port 2 The packets received from por...

Страница 48: ...to a specific port as long as it is also in the same VLAN group The 802 1Q VLAN works by using a tag added to the Ethernet packets The tag contains a VLAN Identifier VID which belongs to a specific V...

Страница 49: ...n the port based VLAN mechanism Broadcast packets will also be forwarded to port 4 of sw2 It means the port based VLAN can not operate a logical VLAN group among switches The VS 2400S supports both po...

Страница 50: ...t the switch for valid value VLAN Mode 802 1Q In the setting port was set to Untagged if devices underneath this port do not support VLAN tagging Thus the switch can send untagged frames to this port...

Страница 51: ...it is an untagged packet Furthermore if the received packet is tagged but not belonging to the same VALN group of the receiving port you can also control the switch to forward or drop the packet The...

Страница 52: ...ecifies the VLAN id or Group id if port based VLAN mode NAME specifies the VLAN group name cpu port no cpu port specifies the CPU port belong this VLAN group 1st LIST specifies the ports to be set to...

Страница 53: ...lan 1 show vlan static Show static VLAN entry information vlan pvid LIST 1 4094 Set port default VLAN id Parameters LIST specifies the ports to be set 1 4094 specifies the port VLAN id show vlan pvid...

Страница 54: ...rame will be dropped or not If set enable drop untagged frame LIST specifies the port list eg 3 6 8 show vlan filter LIST Show VLAN filter setting Parameters LIST specifies the ports to be showed If n...

Страница 55: ...ters join leave leave all specifies a timer Join Leave or Leave All to be set 0 65535 specifies the timer in seconds show garp timer Show GARP timer show gvrp db Show GVRP DB show gvrp gip Show GVRP G...

Страница 56: ...of the IEEE 802 1Q specification Using the QinQ feature service providers can use a single VLAN to support customers who have multiple VLANs Customer VLAN IDs are preserved and traffic from different...

Страница 57: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 56 QinQ Commands qinq enable Enable QinQ no qinq Disable QinQ qinq tpid TPIDVAL Set QinQ tpid Parameters...

Страница 58: ...s qinq uplinkport enable disable LIST A port configured to support network end of QinQ tunnel is called a QinQ uplink port Use this command to enable disabel QinQ uplinkport to specified port s qinq...

Страница 59: ...onnects to the public network The following commands needs to be set qinq enable qinq tpid 8100 qinq userport enable 1 qinq uplinkport enable 16 qinq tunnel add 1 10 1 16 4 0 3 2 Misc Configuration no...

Страница 60: ...ast Packets Broadcast Packets filter Collision Retry off 16 32 48 Parameters off 16 32 48 In half duplex collision retry maximum is 16 32 or 48 times and packet will be dropped if collisions still hap...

Страница 61: ...iguration User can configure the IP setting and fill in the new value ip address ip addr ip mask Set IP address and subnet mask ip default gateway ip addr Set the default gateway IP address show ip Sh...

Страница 62: ...After properly configured packets with the specified direction from the monitored ports are forwarded to the monitoring port Note 1 The default Port Monitoring setting is disabled 2 The analysis port...

Страница 63: ...h queue to put the received packet into In VS 2400S the switch will put received packets into queues according to the settings of 802 1p Priority and Static Port Ingress Priority When the received pac...

Страница 64: ...ample 8 Highest 4 second high means that the switch sends 8 highest priority packets before sending 4 second high priority packets Qos Level 0 7 priority level can map to highest second high second lo...

Страница 65: ...weight 8 Second High weight 4 Second Low weight 2 Lowest weight 1 802 1p priority 0 7 Lowest Lowest SecLow SecLow SecHigh SecHigh Highest Highest 4 0 3 5 1 Per Port Priority port priority disable 0 7...

Страница 66: ...ast or multicast MAC address table entries show mac address table Display MAC address table entries show mac address table static Display static MAC address table entries show mac address table multic...

Страница 67: ...splay filter MAC address table 4 0 3 7 MAC Limit MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table The MAC addresses chosen to be stored in MAC addr...

Страница 68: ...tocol Related Configuration 4 0 4 0 STP RSTP no spanning tree Enable or disable spanning tree spanning tree forward delay 4 30 Set spanning tree forward delay used in seconds Parameters 4 30 specifies...

Страница 69: ...the following relationships 2 hello time 1 maximum age 2 forward delay 1 spanning tree priority 0 61440 Set spanning tree bridge priority Parameters 0 61440 specifies the bridge priority The value mus...

Страница 70: ...rts The remaining commands in this section are only for system with RSTP rapid spanning tree 802 1w capability no spanning tree debug Enable or disable spanning tree debugging information spanning tre...

Страница 71: ...rts to be set Null means all ports no spanning tree port non stp port list Disable or enable spanning tree protocol on this port Parameters port list specifies the ports to be set Null means all ports...

Страница 72: ...anning tree forward delay of CIST in seconds Parameters 4 30 specifies the forward delay in seconds Default value is 15 Note The parameters must enforce the following relationships 2 hello time 1 maxi...

Страница 73: ...priority 0 61440 Set spanning tree bridge priority of CIST and all MSTIs Parameters 0 61440 specifies the bridge priority The value must be in steps of 4096 Default value is 32768 spanning tree proto...

Страница 74: ...T Parameters 1 65535 specifies the bridge revision Default value is 0 spanning tree port path cost 1 200000000 port list Set spanning tree port path cost of CIST Parameters 1 200000000 specifies port...

Страница 75: ...t the port of CIST to be non edge connection Parameters port list specifies the ports to be set Null means all ports no spanning tree port non stp port list Disable or enable spanning tree protocol on...

Страница 76: ...map VLAN list Parameters 0 15 specifies the MSTI instance ID vlan list specifies the mapped VLAN list Null means all VLANs spanning tree mst 0 15 port path cost 1 200000000 port list Set spanning tree...

Страница 77: ...information of CIST show spanning tree port port list Show spanning tree port information of CIST Parameters port list specifies the port to be shown Null means all ports show spanning tree mst config...

Страница 78: ...gement running the simple Network Management Protocol SNMP can be management the IP DSLAM 4 0 4 2 0 System Options Snmp no snmp Enable or disable SNMP Show snmp status Show enable or disable status of...

Страница 79: ...m show snmp system Show SNMP system information 4 0 4 2 1 Community Strings snmp community read sysinfo only read all only read write all community str Set SNMP community string Parameters community s...

Страница 80: ...g 1 65535 specifies the trap receiver port number e g snmp trap 192 168 200 1 public no snmp trap ip addr 1 65535 Remove trap receiver IP address and port number Parameters ip addr specifies the IP ad...

Страница 81: ...s the security name e g no snmp group usm testuser show snmp group Show group list snmp view view name included excluded view subtree view mask Add a view Parameters view name specifies the view name...

Страница 82: ...del noauth auth authpriv specifies the security level read name specifies the access read view name write name specifies the access write view name notify name specifies the access notify view name e...

Страница 83: ...engine id 123456789123456789123456 show snmp engine id Show SNMPv3 engine ID snmp usm user user name md5 none Add SNMPv3 USM user Parameters user name specifies the user name md5 none specifies the a...

Страница 84: ...ement Protocol IGMP is an internal protocol of the Internet Protocol IP suite no igmp Enable disable IGMP snooping no igmp fastleave Enable disable IGMP snooping fast leave If enable switch will fast...

Страница 85: ...ear IGMP snooping statistics counters 4 0 4 4 802 1x This IP DSLAM supports IEEE 802 1x standard which provides port based access control by validating end user s authorization through authentication...

Страница 86: ...s id str specifies NAS identifier string show radius server Show radius server information including radius server IP port number accounting port number shared key NAS identifier dot1x timeout quiet p...

Страница 87: ...ut default 30 seconds Parameters 1 300 specifies the radius server timeout in seconds dot1x max req 1 10 Set 802 1x maximum request retries default 2 times Parameters 1 10 specifies the maximum reques...

Страница 88: ...resses DHCP also helps conserve the limited IP address space because IP addresses no longer need to be permanently assigned to hosts When the DHCP Option 82 feature is enabled on the switch a subscrib...

Страница 89: ...n clients and servers when they are not on the same physical subnet Relay agent forwarding is different from the normal Layer 2 forwarding in which IP datagrams are switched transparently between netw...

Страница 90: ...ple of DHCP relay The following commands are provided for DHCP option82 relay configuration no dhcp option82 Enable disable DHCP option82 function no dhcp relay Enable disable DHCP relay function dhcp...

Страница 91: ...how dhcp configuration Show DHCP configuration information For example refer to the figure of DHCP option 82 in the previous page use the following commands to achieve dhcp option82 dhcp router 18 dhc...

Страница 92: ...eighbor s can be seen through the console only SNMP browser will be supported in the future LLDP Operation Mode LLDP can operate in one of the following modes LLDP Mode Description TxRx mode A port in...

Страница 93: ...ast sending mechanism In this case the interval to send LLDP PDUs changes to one second After the device sends specific number of LLDP PDUs the interval restores to the normal A neighbor is discovered...

Страница 94: ...le Disable LLDP global option lldp hello time 5 32768 Set LLDP hello time which is the time interval between the transmission LLDP info packets The range is from 5 to 32768 seconds Default is 30 secon...

Страница 95: ...IST specifies the ports to be set If not specified all ports are set show lldp Show the LLDP global option all the ports configuration and the neighbor s information show lldp port PORT LIST show LLDP...

Страница 96: ...ANUAL Ver A3 95 State RX and TX Pkt Tx 3868 Pkt Rx 46409 Neighbor Count 1 Neighbor 1 information TTL Time 5879 Class ID 56 78 17 45 25 00 Port ID port 12 System Name System Description Switch v2 16 Po...

Страница 97: ...g level 0 none 1 major 2 all show syslog server Display the syslog server IP and logging level 4 0 6 Reboot switch 4 0 6 0 Reset to Default erase startup config Reset configurations to default factory...

Страница 98: ...the configuration flash image of the switch instead use the keyword flash Parameters ip addr specifies the IP address of the TFTP server remote file specifies the file to be downloaded from the TFTP...

Страница 99: ...ndexed by source and destination IP address protocol and so on Note This function is available only in the 802 1q VLAN enabled environment 4 0 8 0 IPv4 ACL commands no acl group id Delete ACL group Pa...

Страница 100: ...D Any IP Fragement Uncheck Src IP Address Any Dst IP Address Any L4 Protocol Any Port ID Any Hit Octet Count 165074 Hit Packet count 472 acl add edit group id permit deny 0 4094 ipv4 0 255 A B C D A B...

Страница 101: ...ield unCheck Not check IP fragment field 0 65535 specifies the Destination port number if TCP or UDP 0 means don t care 0 26 specifies the Port id 0 means don t care e g acl add 1 deny 1 ipv4 0 192 16...

Страница 102: ...it ACL group for non Ipv4 Parameters add edit specifies the operation group id specifies the group id 1 220 permit deny specifies the action permit permit packet cross switch deny drop packet 0 4094 s...

Страница 103: ...g function no bind group id Delete Binding group Parameters group id specifies the group id 1 220 e g no bind 1 show bind group id Show Binding group information Parameters group id specifies the grou...

Страница 104: ...A B C D specifies the Source IP address 0 0 0 0 means don t care 3rd A B C D specifies the IP Address 1 26 specifies the Port id e g bind add 1 00 11 22 33 44 55 0 192 168 1 1 1 This Binding rule will...

Страница 105: ...rol by Telnet To enter Telnet type the IP address of the Ethernet Switch to connect management system And type User name and password Default User Name admin Default Password admin Notes 1 For securit...

Страница 106: ...tch that default values are as followings If you need change IP address in first time you can use console mode to modify it Default IP Address 192 168 0 100 Subnet Mask 255 255 255 0 Default Gateway 1...

Страница 107: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 106 This is the Web Management Home Overview Fig 4 1 Web Management Home Overview...

Страница 108: ...ese functions are IP address Setting See section 4 2 0 Switch Settings See section 4 2 1 Console Port information See section 4 2 2 Port Configuration See section 4 2 3 SNMP Configuration See section...

Страница 109: ...ay in this page then clicks Apply button to confirm save the settings then the switch reboot must be done to activate the updates The IP address can be statically set or dynamically be assigned by ena...

Страница 110: ...only user can t modify the contents Model name Display the switch s model name Description Display the name of device type MAC Address The unique hardware address assigned by manufacturer default Fir...

Страница 111: ...naged IP DSLAM with POTS splitter USER S MANUAL Ver A3 110 4 2 1 1 Module Info All information in this field is read only user can t modify its contents It is only to display the module port informati...

Страница 112: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 111 4 2 1 2 MISC CONFIG Fig 4 2 1 2 MISC CONFIG...

Страница 113: ...oadcast traffic for a port rises above the threshold you set broadcast storm control becomes active The valid threshold value are 1 2 1 4 1 8 1 12 and off If VS 2400S continued occur hangs up issue pl...

Страница 114: ...Console Port Information Console is a standard UART RS 232 interface to communicate with Serial Port User can use windows HyperTerminal program to link the switch Connect To Configure Bits per seconds...

Страница 115: ...ol area The lower display area will show the port settings for the selected port s Use the other control fields in the upper area to modify the port settings for the selected port s Press Apply to sav...

Страница 116: ...lf mode Rate Control Traffic shaping port1 port 24 supports by port Up ingress and Down egress rate control For example assume port 1 is 10Mbps users can set its effective egress rate at 1Mbps and ing...

Страница 117: ...port broadcast storm filtering option by port The filter mode and filter packets type can be select in Switch Setting Misc Config page Jumbo Frame User can disable Enable port jumbo frame option by p...

Страница 118: ...Monitoring Port It means Analysis port can be used to see the traffic on another port you want to monitor You can connect Analysis port to LAN analyzer Monitored Port The port you want to monitor The...

Страница 119: ...ith unprotected ports Unprotected ports can communicate with any ports including protected ports In default all ports are in Group1 and not protected Fig 4 2 3 2 Protected Port Setting For example in...

Страница 120: ...monitor the current information of each VDSL port such as status upstream rate downstream rate SNR margins for upstream and downstream and firmware version In addition it includes Advance button for c...

Страница 121: ...he transfer of information between management station and agent 4 2 4 0 System Options Use this page to define management stations as trap managers and to enter SNMP community strings User can also de...

Страница 122: ...object information RW Read write Enables requests accompanied by this string to display MIB object information and to set MIB objects Fig 4 2 4 1 Community strings 4 2 4 2 Trap Manager Trap Manager is...

Страница 123: ...DSLAM with POTS splitter USER S MANUAL Ver A3 122 4 2 4 3 SNMPv3 Group Maintain SNMPv3 group Group Name specifies the group name v1 v2c USM specifies the security model Security Name specifies the sec...

Страница 124: ...NUAL Ver A3 123 4 2 4 4 SNMPv3 View Maintain SNMPv3 view View Name specifies the view name Included Excluded specifies the view type View Subtree specifies the view subtree e g 1 3 6 1 2 1 View Mask s...

Страница 125: ...Group Name specifies the group name v1 v2c USM specifies the security model SNMP Access specifies the security level noauth auth authpriv Read View specifies the access read view name Write Name speci...

Страница 126: ...v3 USM User Maintain SNMPv3 USM user User Name Specifies the user name should be the security name defined in group Auth Type Specifies the authorization type md5 none Auth Key Specifies the authoriza...

Страница 127: ...emote syslog server Currently system will do syslog for 3 events cold start warm start and link change In this page user needs to setup the following parameters to activate the syslog Syslog server IP...

Страница 128: ...ation and Alarm Information Users are able to setup alarms and monitor alarm status Configure Alarm Information configuration section Alarm Item Total of four alarms can be set in the VDSL2 IP DSLAM A...

Страница 129: ...DSLAM with POTS splitter USER S MANUAL Ver A3 128 4 2 7 Temperatures Fan Status Temperatures Fan Status allows users to monitor the real time information of the VDSL2 IP DSLAM s temperatures and FANs...

Страница 130: ...e g Tftpd32 exe got the messages from switch which link status is changed on port 9 4 2 8 Firmware Update This system supports firmware update through two different ways TFTP and HTTP 4 2 8 0 TFTP Upd...

Страница 131: ...g 4 2 8 0 TFTP Update The firmware image will first update to the RAM area in system Hit the Update Firmware button to confirm to write to the system s flash memory When the whole process is completed...

Страница 132: ...pdating is using HTTP transfer Just like the file copy in Windows select the valid firmware image file to be uploaded to the switch and hit Submit to start the updating process This is easier than ord...

Страница 133: ...ither TFTP or HTTP transfer 4 2 9 0 TFTP Restore Configuration Use this page to assign a TFTP server IP address and an existing configuration filename to be restored Then press Apply button to start t...

Страница 134: ...etting SNTP stands for Simple Network Time Protocol SNTP is a simpler version of Network Time Protocol NTP which is a system for synchronizing the clocks of network computer systems By enabling SNTP f...

Страница 135: ...the time zone After UTC UTC hh hh hours For example Taipei UTC 08 choose After UTC Before UTC UTC hh hh hours For example San Francisco UTC 08 choose Before UTC Time Range This field is for setting u...

Страница 136: ...3 135 4 3 L2 Features This switch provides the following L2 features VLAN Configuration See section 4 3 0 Forwarding Filtering See section 4 3 1 IGMP Snooping See section 4 3 2 Spanning Tree STP See s...

Страница 137: ...the same VLAN members Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still pl...

Страница 138: ...0 0 0 Port Based VLAN First select Port based VLAN in VLAN Operation Mode Then click Add to create a new VLAN group Enter the VLAN name group ID and select the members for the new VLAN Then click App...

Страница 139: ...Q VLAN In this page user can create 802 1Q tag based VLAN There are up to 512 VLAN groups to provide configuration While VLAN Operation Mode is changed to 802 1Q VLAN all ports on the switch belong to...

Страница 140: ...nd add tagged member ports to it 1 From the main menu click Administrator VLAN configuration click Add then you will see the page as follow 2 Type a name for the new VLAN 3 Type a VID 1 4094 The defau...

Страница 141: ...3 802 1Q VLAN Add 6 Uses this page to set the outgoing frames are VLAN Tagged frames or no Then click Apply Tag outgoing frames with VLAN Tagged Untag outgoing frames without VLAN Tagged Note CPU Port...

Страница 142: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 141 VLAN Filters Fig 4 3 0 0 4 VLAN Filters...

Страница 143: ...t support tagging This switch allows user to set one PVID for each port the range is 1 4094 default PVID is 1 The PVID must as same as the VLAN ID that the port belong to VLAN group or the untagged tr...

Страница 144: ...IEEE 802 1Q specification which defines a method of tagging frames with VLAN configuration data GVRP allows automatic VLAN configuration between the switch and nodes If the switch is connected to a de...

Страница 145: ...e range of VLAN IDs to each customer would restrict customer configurations and could easily exceed the VLAN limit 4096 of the IEEE 802 1Q specification Using the QinQ feature service providers can us...

Страница 146: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 145 Fig 4 3 0 2 QinQ VLAN...

Страница 147: ...designed for service providers who carry traffic of multiple customers across their networks and are required to maintain the VLAN and Layer 2 protocol configurations of each customer without impacti...

Страница 148: ...er USER S MANUAL Ver A3 147 4 3 1 Forwarding and Filtering In this submenu the following functions related to forwarding and filtering are provided Dynamic MAC Table See section 4 3 1 0 Static MAC Tab...

Страница 149: ...able shows the MAC addresses learned by the switch The table will be shown by pages if larger than 500 MAC Addresses Fig 4 3 1 0 Dynamic MAC Address Click Clear to clear Dynamic MAC address table Clic...

Страница 150: ...ch This saves the switch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again This table can associate with the Security field in P...

Страница 151: ...rt number Switch port number to associate with the MAC address in a MAC entry Vlan ID If tag based IEEE 802 1Q VLANs are enabled static MAC address can be associated with individual VLANs Type the VID...

Страница 152: ...ltered based on the destination MAC addresses Fig 4 3 1 2 MAC Filtering MAC Address MAC address that wants to be filtered Vlan ID If tag based 802 1Q VLAN are enabled type the VID in this field to ass...

Страница 153: ...lticast group VID and member port in here IP multicast addresses range from 224 0 0 0 through 239 255 255 255 Fig 4 3 2 IGMP Snooping The Internet Group Management Protocol IGMP is an internal protoco...

Страница 154: ...ven group indicated in the report message Leave Group A message sent by a host to the queries to indicate that the host has quit being a member of a specific multicast group IGMP protocol Enable disab...

Страница 155: ...ops in switching networks Enable STP to ensure that only one path at a time is active between any two nodes on the network You can enable STP on web management s switch setting advanced item select en...

Страница 156: ...with POTS splitter USER S MANUAL Ver A3 155 You can view STP port status about the switch Such as following screen Fig 4 3 3 0b STP system You can configure STP parameters then click Apply button to...

Страница 157: ...e root bridge The bridge with lowest value has the highest priority and is selected as the root Value range 0 61440 the value must be in steps of 4096 Default value is 32768 Max Age You can change Max...

Страница 158: ...the value used for the ageing time of dynamic entries in the Filtering Database while received BPDU indicate a topology change Value range 4 30 Default value is 15 NOTE The above parameters must enfo...

Страница 159: ...ion of the path through this port when the port is the root port to the total cost of the path to the root for this bridge Value range 1 65535 Port Priority You can make it more or less likely to beco...

Страница 160: ...rames assigned to different VLANs to follow separate paths each based on an independent Multiple Spanning Tree Instance MSTI within Multiple Spanning Tree MST Regions composed of LANs and or MST Bridg...

Страница 161: ...h POTS splitter USER S MANUAL Ver A3 160 You can view MSTP CIST port status about the switch Such as following screen Fig 4 3 3 1b MSTP system You can configure MSTP parameters then click Apply button...

Страница 162: ...lue of STP sate is disabled You can select STP Debug item to output MSTP debug information If you want to disable the debug please cancel the item Default value of STP Debug is disabled STP protocol v...

Страница 163: ...s 20 Hello Time You can change Hello time value The time interval between the transmission of Configuration BPDUs by a Bridge that is attempting to become the Root or is the Root Value range 1 10 Defa...

Страница 164: ...400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 163 The following parameters can be configured on each CIST port click Apply button to set the values Fig 4 3 3 1d MSTP sys...

Страница 165: ...in Edge You can choose the value of YES if you want the port to be edge port If the port is edgeport when the port becomes a Designated Port it can rapidly transition to the Forwarding Port State Valu...

Страница 166: ...t Information option may use the information to implement IP address or other parameter assignment policies The DHCP Relay can forward the DHCP broadcast packets to a DHCP server in a different subnet...

Страница 167: ...Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 166 4 3 4 1 DHCP Relay To enable DHCP relay function need to enable global dhcp relay and special port dhcp relay Then select DHCP router port...

Страница 168: ...5 Trunking Trunking function allows users to combine several ports or connections together to create one single connection which has a higher and faster connection speed Trunking is also called Link A...

Страница 169: ...ACP checkbox for enable or disable LACP algorithm by check on the checkbox System Priority this value is for identifying the active LACP of this VDSL2 IP DSLAM Note the lowest value presents the highe...

Страница 170: ...tor information This section allows users to review trunk information Two data are reviewed in this section Group Key the trunk group ID Port No the port member of this trunk group Port1 Port24 Mod1 M...

Страница 171: ...Ver A3 170 Static Activity This area is for setting up LACP mode active or passive Active the active port will send LACP packets automatically Passive the passive port will not send LACP packets but i...

Страница 172: ...A3 171 4 4 Access Control List Packets can be forwarded or dropped by ACL rules include IPv4 or non Ipv4 NV802S can be used to block packets by maintaining a table of packet fragments indexed by sour...

Страница 173: ...and Binding SIP SMAC Port Fig 4 4b Access Control List Enable Disable ACL rule Select an ACL entry which you want to enable disable in the Current List Then click Enable Disable to execute Reset ACL...

Страница 174: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 173 4 4 0 IPv4 In Packet Type Binding box should select IPv4 Fig 4 4 0 IPv4...

Страница 175: ...itch b Deny Drop packet Permit VLAN Any VID a Any Any Vlan id b VID 1 4094 A certain vlan id Any Packet Type IPv4 Non IPv4 Binding a IPv4 Set Ipv4 packet field b Non IPv4 Set non Ipv4 packet field c B...

Страница 176: ...5 Any IP Fragment Set this field if Packet Type is IPv4 else ignore Uncheck Check a Uncheck Not check IP fragment field b Check Check IP fragment field Uncheck L4 Protocol Set this field if Packet Typ...

Страница 177: ...ld if Packet Type is IPv4 else ignore Any DHCP 67 TFTP 69 NetBios 137 Any Port Set this field if Packet Type is IPv4 else ignore 0 65535 If UDP port not find in UDP field you can direct assign number...

Страница 178: ...inding box should select Non IPv4 Fig 4 4 1 Non IPv4 The related parameters are shown in the following table Items Option Default value Group ID 1 220 max 220 ACL group Action Permit Deny c Permit Per...

Страница 179: ...on IPv4 Set non Ipv4 packet field f Binding Set binding function IPv4 Ether Type Set this field if Packet Type is Non IPv4 else ignore Any ARP 0x0806 IPX 0x8137 Any Type Set this field if Packet Type...

Страница 180: ...t has specific IP address and MAC address can use network We can set specific IP address MAC address VLAN id and port id to bind and device can cross switch if all conditions match Use binding functio...

Страница 181: ...rop packet Permit VLAN Any VID e Any Any Vlan id f VID 1 4094 A certain vlan id Any Packet Type IPv4 Non IPv4 Binding g IPv4 Set Ipv4 packet field h Non IPv4 Set non Ipv4 packet field i Binding Set bi...

Страница 182: ...S VoIP QoS VoIP Parameter Option Default value Priority 0 7 7 PortID 0 1F 0 PortID Mask 0 1F 0 Protocol 0 FF 0 Protocol Mask 0 FF 0 Source Port 0 FFFF 0 Source Port Mask 0 FFFF 0 Destination Port 0 FF...

Страница 183: ...with POTS splitter USER S MANUAL Ver A3 182 Parameter Value GID 1 Action QoS VoIP VLAN Any Priority 7 PortID 0 PortID Mask 0 Protocol 11h Protocol Mask 1FH Source Port 2710h Source Port Mask FF00h De...

Страница 184: ...rity 4 5 0 Security Manager In this page user can change user name and password with the following parameters User Name Type the new user name Assign Change password Type the new password Reconfirm pa...

Страница 185: ...lt of first come first save policy Once a MAC address is stored in the MAC address table it stays in until it is aged out When an opening is available the switch stored the first new MAC address it se...

Страница 186: ...aracteristics and of preventing access to that port in cases in which the authentication and authorization process fails In the beginning 802 1x configuration page is disabled because 802 1x is disabl...

Страница 187: ...ing Port The UDP port number used by the authentication server to retrieve accounting information default 1813 Shared Key A key shared between this switch and authentication server NAS Identifier A st...

Страница 188: ...orized Fa Force the specific port to be authorized Au The state of the specific port was determined by the outcome of the authentication No The specific port didn t support 802 1x function 4 5 2 2 Mis...

Страница 189: ...t conditions in the exchanges between the supplicant and authentication server default value 30 seconds Server Timeout Used to determine timeout conditions in the exchanges between the authenticator a...

Страница 190: ...utput queue and 802 1p 8 level priority to 4 level queue mapping QoS functions Strict and weight round robin WRR QoS mode are supported 4 6 0 QoS Configuration This page is mainly to set the QoS mode...

Страница 191: ...e These options represent the number of higher priority packets sent before one lower priority packet is sent For example 8 Highest 4 second high means that the switch sends 8 highest priority packets...

Страница 192: ...LAM with POTS splitter USER S MANUAL Ver A3 191 Port Number the ports in the switch Port Priority port priority can be disable or 0 7 Per Port priority setting can be displayed like the following figu...

Страница 193: ...e only the IP Precedence part of the field was ever used At its simplest the higher the value of the IP Precedence field the higher the priority of the IP packet In RFC 2474 the definition of this ent...

Страница 194: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 193 DSCP priority of ToS setting can be displayed like the following figure Fig 4 6 2a Per DSCP Configuration...

Страница 195: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 194 Per Port status setting can be displayed like the following figure Fig 4 6 2b Per Port status configuration...

Страница 196: ...AF 1 Low AF21 IPTV VOD 010 010 18 0x12 72 0x48 2 Medium AF22 IPTV VOD 010 100 20 0x14 80 0x50 3 High AF23 IPTV VOD 010 110 22 0x16 88 0x58 Flash 3 011 AF 1 Low AF31 IPTV Broadcast 011 010 26 0x1a 104...

Страница 197: ...tus Port statistics 4 7 0 Port Status This page provides current status of every port that depends on user s setting and the negotiation result Fig 4 7 0 Port Status State Display port statuses disabl...

Страница 198: ...play the backpressure is enabled or disabled in half mode Rate Control Traffic shaping Display the rate control setting Up Ingress Display the port effective ingress rate of user setting Down Egress D...

Страница 199: ...naged IP DSLAM with POTS splitter USER S MANUAL Ver A3 198 4 7 1 Port Statistics The following information provides a view of the current status of the whole unit Press Reset button to clean all count...

Страница 200: ...A3 199 4 8 Reset System The page to reset the switch to default configuration is shown as below Warning All configuration settings are restored to factory default setting Fig 4 8 Reset System 4 9 Rebo...

Страница 201: ...VS 2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 200 Chapter 5 VDSL2 functions The page to configure and show VDSL2 functions Figure 5 1 1 VDSL2 Configuration...

Страница 202: ...rofiles and bandplans to meet regional service provider requirements The frequency bandwidth has increased to 30 MHz with configuration options at 8 5 MHz 12 MHz 17 7 MHz and 30 MHz Band profile and b...

Страница 203: ...ifferent connection status of data rate and distance 1 AnnexA_R_POTS_D 64_EU 64_30a 2 AnnexA_R_POTS_D 32_EU 32_17a 3 AnnexA_R_POTS_D 32_EU 32_12b 4 AnnexA_R_POTS_D 32_EU 32_12a 5 AnnexA_R_POTS_D 32_EU...

Страница 204: ...B8 15 998ADE30 M2x NUS0 M 32 AnnexB_B8 16 998ADE30 M2x NUS0 A 33 AnnexC_POTS_25 138_b 34 AnnexC_POTS_25 276_b 35 AnnexC_TCM_ISDN SNR SNR values for both downstream and upstream 6dB 24dB Rate Limit Ds...

Страница 205: ...view the details of existing profiles in the following details User Name The profile name System Name VDSL2 Band profile SNR Ds Us SNR value Rate Limit Ds Us The data rate INP 30a Ds Us INP level for...

Страница 206: ...B X X AnnexA_R_POTS_D 32_EU 32_ 8b A43 X AnnexB_B8 8_998E17 M2x MUS0 B43 AnnexA_R_POTS_D 32_EU 32_ 8c A43 AnnexB_B8 9_998E17 M2x MUS0 M B43 AnnexA_R_POTS_D 32_EU 32_ 8d A43 AnnexB_B8 10_998ADE17 M2x M...

Страница 207: ...ch need to pass this traffic via the high speed switching fabric Flexible Configuration This Switch is not only designed to segment your network but also to provide a wide range of options in setting...

Страница 208: ...ervice Provider s fiber node to the buildings and customers houses The Intelligent VS 2400S provides a high speed 100Mbps transmission over phone wiring over a single Internet account to provide simul...

Страница 209: ...onnected to a IP sharing device then to a xDSL or Cable Modem Note For network applications that actually require a Router e g Interconnecting dissimilar network types attaching the SWITCH directly to...

Страница 210: ...other that is functioning properly Check the power cord with another device If these measures fail to resolve the problem have the unit power supply replaced by an qualified distributor 2 Symptom Link...

Страница 211: ...why we are seeing such varied results and has there been any other reported problem with this feature lately Answer Regarding our VDSL2 IP DSLAM principle of bandwidth control which must rely on flow...

Страница 212: ...ach mode as 12a or 8d AnnexB 8 Question Sometimes the IP DSLAM unstable Cause Due to heavy noise or impulse noise of field environment caused unstable Solution 1 If VS 2400S hangs up please enable bro...

Страница 213: ...B connects to port 2 and join to Internet through port 10 3 User C connects to port 3 and join to Internet through port 10 4 User D connects to port 4 and join to Internet through port 10 5 User A iso...

Страница 214: ...ter USER S MANUAL Ver A3 213 VLAN Filters Add VLAN Group There are 256 VLAN groups available for configuration Add a VLAN Group VID 21 member ports port 1 port 10 Note Do not change the default_1 grou...

Страница 215: ...R S MANUAL Ver A3 214 Note If Vlan group include cpu port The member of this group can management this vdsl2 Ipdslam Select Untag or Tag Setup Unless the device computer or switch which connect to por...

Страница 216: ...SL2 Managed IP DSLAM with POTS splitter USER S MANUAL Ver A3 215 Add a VLAN Group Name UserB VID 22 member ports port 2 port 10 with Untag Add a VLAN Group Name UserCD VID 23 member ports port 3 port...

Страница 217: ...VDSL2 2 4 User D connect to port 2 of VDSL2 2 and join to Internet through port 10 of VDSL2 2 5 User A isolate with Users B C and D 6 User C isolate with Users A B and D 7 User B and D in the same Gro...

Страница 218: ...dd VLAN Group Do not change the default_1 group settings Add a VLAN Group Group name UserA VID 11 member ports port 9 port 10 Select Untag or Tag Setup for VID 11 group Port Number Untag Tag Select 9...

Страница 219: ...3 PC C connect to port 3 of VDSL2 and join to Internet through port 9 of VDSL2 4 PC D connect to port 1 of Switch and join to Internet through port 25 of Switch 5 PC E connect to port 2 of Switch and...

Страница 220: ...1 2 3 on left side of the VS 2400S connects to VLAN9 client Port 9 of the VS 2400S connects to public network 4 Add six VLAN Groups as follow form VDSL2 VLAN Group Switch VLAN Group VLAN VID Untag Tag...

Страница 221: ...l1 VID5 within port1 25 2 Set tunnel2 VID5 within port2 9 for VDSL2 and Switch set tunnel2 VID5 within port2 25 3 Set tunnel3 VID5 within port3 9 for VDSL2 and Switch set tunnel3 VID5 within port3 25...

Страница 222: ...alled If one or more components appear to be malfunctioning e g the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning...

Страница 223: ...from the network 3 When cascading two devices using RJ 45 station ports at both ends of the cable i e an Auto MDIX port if supports a auto MDIX used crossover cable is not need External Adapters Make...

Страница 224: ...twork Control by Telnet and Web FCC Mark Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are d...

Страница 225: ...may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electron...

Страница 226: ...e or which contain defects which are in any way attributable to improper installation or to alteration or repairs made or performed by any person not under control of the original owner The above warr...

Отзывы: