6. CAUTION

7. WARNING

The RubbaFIX

®

 MELTA

®

 Pro can cause severe injury if incorrectly used. Those who use and maintain the system should 

be trained on its proper use warned of its dangers and should read the entire manual before attempting to set up, operate 
or adjust the machine.

•     Do not squeeze the trigger switch on the gun when the system is cold.
•     Do not adjust the Flow Control Knob when the system is cold.
•     Do not allow the pump motor to stall.  A prolonged stall will cause the motor to go into thermal overload.
•     Do not connect or disconnect electrical connectors or remove components with the power on, This will prevent 

       arcing of electrical contacts and possible failure of components.

•     Always close and secure the control panel access cover 13 to protect internal electrical components.
•     Always operate the system with the tank lid Closed.
•     Foot brake must always be on when machine is in use.

•     Refer to RubbaFIX

®

 Safety Data Sheet (SDS) for the following Warning instructions before using RubbaFIX

®

 MELTA

®

   

       Pro Applicator. 

•     RubbaFIX

®

 Pty Ltd recommends an independent Risk Assessment should be carried out on this equipment before a 

       decision is made to use it underground.

•     Working on or around the RubbaFIX

®

 MELTA

®

 Pro and equipment can cause severe burns.

•     Use eye protection, Thermal gloves and protective clothing while operating. 
•     Before using any RubbaFIX

®

 MELTA

®

 Pro equipment, determine proper electrical requirements as per all applicable  

       codes.

•     Ensure hazardous material(s) that are toxic, heat or fire sensitive are not located in the immediate vicinity of the 

       RubbaFIX

®

 MELTA

®

 Pro as fire, explosion, personal injury, property and/or equipment damage can result.

•     The RubbaFIX

®

 MELTA

®

 Pro system is equipped with over temperature protection as a necessary safety device.

•     Run-away heating can cause hot melt materials to exceed their flash point.

At RubbaFIX

®

 Pty Ltd, we pay special attention to the needs of operators and service personnel when designing equipment, 

but molten repair compounds are dangerous and can cause severe burns. Extreme care must be exercised to insure 
personnel safety.

Содержание MELTA Pro

Страница 1: ...Australia Toll Free 1800 352 228 International 61 2 8853 3000 www rubbafix com Operating Instructions for RubbaFIX MELTA Pro Applicator...

Страница 2: ...g Instructions 6 4 Product Identification 7 4 1 Applicator Gun 8 4 2 Front Control Panels 8 5 Control Panel Settings 10 6 CAUTION 11 7 WARNING 11 8 Service and Maintenance 12 9 Trouble Shooting 13 10...

Страница 3: ...pleteness of the information below We make no warranties which extend beyond the description contained herein and any information given does not constitute any warranty of merchantability or fitness f...

Страница 4: ...ar heat resistant PPE and clothing whenever you work with this equipment Electrical Hazard Environmental Hazard Caution Hot Surface Accident prevention regulations VBG 125 W26 hot surfaces such as mac...

Страница 5: ...s designed to do Is not used by anyone untrained and unable to operate it properly Is only used whilst wearing the correct PPE and clothing Is not used in damp or wet environments An independent Risk...

Страница 6: ...RubbaFIX Product Data Sheet PDS before operating RubbaFIX MELTA Pro Applicator website link www rubbafix com au Refer to troubleshooting guide for more information of operating RubbaFIX MELTA Pro App...

Страница 7: ...E temps meet the target ZONE temps the system is up to temperature Do not operate until this has happened 12 Turn the Pump Switch 8 ON 13 The pump is activated by the trigger switch 11 which is locate...

Страница 8: ...4 Product Identification 1 2 3 6 7 4 5 8 10 11 14 9 12 13...

Страница 9: ...Australia Toll Free 1800 352 228 International 61 2 8853 3000 See our full range online at www rubbafix com 4 1 Applicator Gun 4 2 Front Control Panels 12 21 22 18 19 20 5 15 6 16...

Страница 10: ...seconds When the Set Mode light illuminates continue to hold the zone button and adjust the set temperature using the arrow keys Set temperatures range from 38 C to high limit in 1 C increments 16 St...

Страница 11: ...hose may need to be adjusted higher to achieve the ideal product temperature The belt also needs to be preheated using a hot air gun to maximise product adhesion Actual Temperature During operation a...

Страница 12: ...the following Warning instructions before using RubbaFIX MELTA Pro Applicator RubbaFIX Pty Ltd recommends an independent Risk Assessment should be carried out on this equipment before a decision is m...

Страница 13: ...l on a regular basis The frequency of maintenance depends on usage Checks and maintenance should include but are not limited to functionality of the lid latch the wire stand and the power cord 5 Ensur...

Страница 14: ...ar coupling Check that tank has Rubba x material Check nozzle for blockage Check hose for blockages or damage Check that tank has Rubba x material Check hose feed connector for leaks Adjust to require...

Страница 15: ...or current IEC 61180 1 This is to certify that the above applicator in the design marketed is in conformity with the following EMC guidelines AS NZS 61000 6 3 16 6 Gladstone Rd Castle Hill NSW Please...

Страница 16: ...tic Compatibility Directive EMC 2014 30 EU Restriction of Hazardous Substances RoHS Directive 2011 65 EU WEE Directive 2012 19 EU 4 Standards EN61010 2 010 2014 EN 61000 6 3 2007 A1 2011 EN 61000 6 3...

Страница 17: ...all be allowed in respect of a MELTA Pro which has been injected with non RubbaFIX approved products neglected or improperly stored transported handled installed connected operated used or maintained...

Страница 18: ...C 10 amp Hz 50 60 Drive Motor All electric fractional HP Length of Electric Cord 1 8 Metres Pump Cast iron with steel gears Temperature Control Micro Processor Dimensions 28 cmx 61 cm x 51 cm high app...

Страница 19: ...ank Heaters Main Power Breaker L1 Pump Switch Display Board 241 213 PLUG INTO MOTHERBOARD FAULT HOSE GUN 8 9 10 11 Hose Connector 14 pin Ribbon Cable 220 053 FUSE CHART F2 HOSE GUN FUSE 8 AMP H2 2 F3...

Страница 20: ...N INPUT H6 A7 A6 M4 M3 C1 7 C1 6 C2 4 C2 3 HOSE GUN FUSE F1 AIR BAG L2 C1 2 HOSE HEATER C1 5 TANK HEATERS C1 4 GUN HEATER HOSE RELAY H2 H5 ACC INPUT C3 7 C3 6 POWER SWITCH POWER SWITCH TANK RELAY TANK...

Страница 21: ...nfo rubbafix com Unit 16 6 Gladstone Road Castle Hill NSW 2154 Australia Mail To PO Box 6467 Baulkham Hills BC NSW 2153 Australia Head Office Contact For further information on how RubbaFIX solutions...

Отзывы: