1. Adjustable Rear Handle:
2. Hinged Lid:
The lid has a spring loaded hinge and a lock clip
at the front to ensure the lid is always closed during operation.
3. Tank
4. Adjustable Front Handle
5. Pump Control:
"ON/OFF" Switch: Turns pump motor
circuit "ON" or "OFF.
6. Main Power Switch:
Turns the system "ON" or "OFF."
7. Control Panel
8. Rear Handle Angle Adjuster:
To adjust rear handle release
catches on the bottom of both arms, lower handle to new position
and re-insert catches.
9. Floor lock:
To apply brace and lift rear wheels off the ground,
push down on the outer lever. To release the floor lock and return
the rear wheels to the ground push down on the inner lever.
10. Flow Control:
Refer to section 4, for full adjustment instruc-
tions.
11. Gun Hook:
This is used to rest the applicator gun on when
the gun is not being used.
12. Applicator Gun:
The control gun for applying the RubbaFIX
®
product.
13. Access Cover:
This cover should always be in situ when the
machine is in use.
14. Serial Number Placard:
The serial number placard is located
at the lower rear panel of the machine.
15. Set Temperatures:
Press and hold the Tank, Hose, or Gun
button for 2 seconds. When the Set Mode light illuminates,
continue to hold the zone button and adjust the set temperature
using the arrow keys. Set temperatures range from 38°C to high
limit in 1°C increments.
16. Standby:
All zones are lowered by 50%. Pump will not
operate while in standby.
Auto Standby & Auto Off Timer:
When activated, the system
will enter standby after three (3) hours of continuous inactivity,
then off after three (3) more hours. To activate press and hold the
Standby button and turn the system on. Use the arrow buttons to
turn “ON” or "OFF." Turn the main power switch OFF and then
ON to begin operation.
17. Actual Temperatures:
During operation the actual
temperatures scan through each zone every five (5) seconds.
Press and release any zone button to display that zone’s actual
temperature.
18. Over Temp:
If any zone reaches 15°C above the high limit,
the over temp light will illuminate and the system will shut off.
The temperature display will read "OFF" and the light above the
faulted zone will flash.
19. Pump Ready:
The pump will not operate until the actual
tank temperature is within 15°C of set temperature.
20. Set Lock:
Lit when feature is “ON."
21. Applicator Nozzle:
Hot product comes out of the nozzle
under pressure when the trigger switch is squeezed.
22. Trigger Switch:
The trigger switch will allow product to flow
when squeezed.