10 Installation
DSI-2008
Bosch Security Systems, Inc.
User Manual
F.01U.193.295
Rev. 05
2-Wire Audio Connections
RTS TW Audio Connections
To
configure 2-wire connections
, do the following:
1.
Use standard TW intercom cables. Standard TW system cables can carry either one (1) or two (2) channels. Each
hybrid in the DSI 2008 can only interface one (1) TW channel to one (1) 4-wire channel, the channel is determined by
the front panel 2W CHAN SEL switch. If your TW system cable is only carrying one (1) channel, or if you only need
to connect one (1) channel, connect directly to J1A (System A) or J1B (System B). If your TW system cable is
carrying two (2) channels, and you want to connect to both, use a TW-5W or similar device.
NOTE:
The DSI 2008 features internal DC isolation. You can therefore connect to the DSI 2008 to powered TW
cables, and it will not draw any power from the TW system.
2.
On the DSI 2008 front panel: For System A and System B, set the 2W CHAN SEL switch to the appropriate position.
To interface to TW channel 1 select position 1; for TW channel 2, select position 2.
NOTE:
If the System A or System B is not used, set the 2W CHAN SEL switch to the OFF position and attach a dummy
load to the TW XLR connector.
Audiocom Audio Connection
You can directly connect standard Audio 1-channel cables.
1.
Connect
one (1) Audiocom channel to the J1A connector
on the back of the DSI 2008 (System A).
2.
Connect a
second Audiocom channel to the J1B connector (System B)
.
If your Audiocom system uses 2-channel cables, use a JB-2 Junction Box to split the channels (Figure 3)
NOTE:
The DSI 2008 features internal DC isolation. You can therefore connect the DSI 2008 to powered Audiocom
cables, and it will not draw any power from the Audiocom system.
3.
On the DSI 2008 front panel, set the
2W CHAN SEL switches for System A or System B to the BAL position
.
NOTE:
If System A or System B hybrid will not be used, set the 2W CHAN SEL switch to the off position and
attach a dummy load to the TW XLR connector.
Содержание DSI 2008
Страница 4: ...Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05 iv DSI 2008...
Страница 6: ...Bosch Security Systems Inc User Manual 2 DSI 2008 Rev 05 F 01U 193 295...
Страница 10: ...6 Description and Specifications DSI 2008 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05...
Страница 22: ...18 Installation DSI 2008 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05...
Страница 27: ...DSI 2008 23 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05 Notes...
Страница 28: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...