4 Description and Specifications
DSI-2008
Bosch Security Systems, Inc.
User Manual
F.01U.193.295
Rev. 05
Half-rack Wide, 1RU High
: Two DSI 2008s fit into a single rack space. Compatible with RTS TW rack mount hardware.
Can be mixed with other TW equipment.
Universal Power Pack
: Ready for worldwide use. Automatically accepts any main voltage from 100-250 VAC, 50/60Hz.
Power pack equipped with locking DIN connector for attachment to the DSI 2008.
Front and Back Panel Descriptions
Front Panel
There is a power on/off and call indicator at the left of the front panel. This indicator lights continuously when the DSI 2008 is
turned on and flashes when an incoming call signal is detected, if the call signal option board is installed. The remainder of the
front panel is divided into controls and indicators for the two separate hybrids, labeled SYSTEM A and SYSTEM B. For each
hybrid, there is a 10-segment, peak reading level meter to display the 4-wire output level (TO 4W). There is a recessed level
set control to the left of the 4-wire meter (LEVEL SET) and there is also a recessed, 5-position range select control for the 4-
wire output (4W LEVEL REF SEL). Under the 4-wire meter, is an identical meter for the 2-wire output level, and there is a
recessed level set control for the 2-wire output to the left of the meter. Under the 2-wire meter, there is a recessed, 5-position
selector. The selector has two OFF positions for when no 2-wire input is connected. The three remaining switch positions
select the 2-wire system as follows: position 1 selects RTS TW channel 1; position 2 selects RTS TW channel 2, the BAL
position selects an Audiocom balanced channel. There are 3 LED indicators to display the current selection.
Back Panel
The power pack connector is located at the right end of the back panel. This is a locking DIN connector. The remainder of the
back panel is divided into connectors for the two separate hybrids. Connectors are labeled with “J” numbers followed by “A”
or “B” to indicate System A or System B. For each hybrid, there is an AUX connector. This is used to connect to/from the
optional call signal card. Below the AUX connector, there are both a DB-9F connector and an RJ-11 connector for 4-wire
intercom connection. These are directly compatible with standard keypanel cables. Next to the 4-wire connectors, there is a 3-
pin female XLR audio connector for connection to the 2-wire intercom system.
FIGURE 1.
DSI 2008 Reference View
Содержание DSI 2008
Страница 4: ...Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05 iv DSI 2008...
Страница 6: ...Bosch Security Systems Inc User Manual 2 DSI 2008 Rev 05 F 01U 193 295...
Страница 10: ...6 Description and Specifications DSI 2008 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05...
Страница 22: ...18 Installation DSI 2008 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05...
Страница 27: ...DSI 2008 23 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05 Notes...
Страница 28: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...