background image

DSI-2008

Installation  11

Bosch Security Systems, Inc.

User Manual

 F.01U.193.295

Rev. 05

Other 2-wire Audio Connection

1.

Use the J1A connector on the back of the DSI 2008 to connect one 2-wire line to the System A hybrid. Use the J1B 
connector to connect a second 2-wire line to the System B hybrid. The pin configuration for the J1A and J1B connec-
tors depend on whether you are connecting a balanced or unbalanced 2-wire line, as follows:

NOTE:

TW systems must provide termination on the audio channel. 

There are two (2) possible configurations for unbalanced connection:

2.

On the DSI 2008 front panel, set the 

CHAN SEL switches

 as follows:

Balanced Configuration

: set the CHAN SEL switches to the BAL position.

Unbalanced Configuration 1

: set the CHAN SEL switches to position 1.

Unbalanced Configuration 2

: set the CHAN SEL switches to position 2.

FIGURE 3.

Using a JB-2 Junction Box to split a 2-channel Audiocom cable into two 1-channel cables.

Balanced Configuration

Pin 1

No Connection

Pin 2

Balanced Audio + Input/Output

Pin 3

Balanced Audio - Input/Output

** Termination 300 

Unbalanced Configuration 1

Pin 1

Audio Common

Pin 2

Audio Input/Output

Pin 3

No Connection

** Termination 200 

Unbalanced Configuration 2

Pin 1

Audio Common

Pin 2

No Connection

Pin 3

Audio Input/Output

** Termination 200 

Содержание DSI 2008

Страница 1: ...F 01U 193 295 Rev 05 SEPTEMBER 2012 User Instructions DSI 2008 Digital System Interface ADAM ADAM M ADAM CS Zeus and Zeus III Intercoms...

Страница 2: ...he manufacturer of the equipment described herein makes no expressed or implied warranty with respect to anything contained in this manual and shall not be held liable for any implied warranties of fi...

Страница 3: ...If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs conveni...

Страница 4: ...Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05 iv DSI 2008...

Страница 5: ...udio Connection 10 Other 2 wire Audio Connection 11 4 Wire Call Signal Connections 12 Call Signal Connection for ADAM ADAM M ADAM CS Zeus and Zeus III 12 Call Signal Connections for other 4 wire Commu...

Страница 6: ...Bosch Security Systems Inc User Manual 2 DSI 2008 Rev 05 F 01U 193 295...

Страница 7: ...ms Features Two 2 Independent Hybrids Interface two 2 separate 2 wire lines to two 2 separate 4 wire lines Automatic Nulling Digital hybrids eliminate all nulling and ducking adjustments Quick trouble...

Страница 8: ...wire output 4W LEVEL REF SEL Under the 4 wire meter is an identical meter for the 2 wire output level and there is a recessed level set control for the 2 wire output to the left of the meter Under th...

Страница 9: ...ls 10dBu 0dBu 4dBu 8dBu 12dBu System to System Frequency Response 200Hz to 3 5kHz 4dB THD 1 channel output with nominal input Environmental Operating Temp 20 C to 50 C 4 F to 122 F Storage Temp 40 C t...

Страница 10: ...6 Description and Specifications DSI 2008 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05...

Страница 11: ...e DSI 2008 is physically positioned near the 4 wire operator this can be used as an incoming call indication for the 4 wire system if desired although other methods are available as described in 4 Wir...

Страница 12: ...tches to the position which most closely matches the audio input and output levels of your 4 wire system NOTE If you don t know the levels select the 8dB position for now 9 Pin Connection Connector Ty...

Страница 13: ...DSI 2008 Installation 9 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05 FIGURE 2 Rack Mount Configurations...

Страница 14: ...front panel For System A and System B set the 2W CHAN SEL switch to the appropriate position To interface to TW channel 1 select position 1 for TW channel 2 select position 2 NOTE If the System A or S...

Страница 15: ...for unbalanced connection 2 On the DSI 2008 front panel set the CHAN SEL switches as follows Balanced Configuration set the CHAN SEL switches to the BAL position Unbalanced Configuration 1 set the CH...

Страница 16: ...n also use that for connections Table 1 on page 13 and Table 2 on page 14 As an alternative to using the GPI you can use external components to send and receive call signals as described in Call Signa...

Страница 17: ...PI Input 1 High 5 18 VDC 2 GPI Input 2 High 5 18 VDC 3 GPI Input 3 High 5 18 VDC 4 GPI Input 4 High 5 18 VDC 5 GPI Input 5 High 5 18 VDC 6 GPI Input 6 High 5 18 VDC 7 GPI Input 7 High 5 18 VDC 8 GPI I...

Страница 18: ...ummarized in the UIO 256 Manual GPI INPUT PIN NUMBERS UIO 256 Frame 1 UIO 256 Frame 2 UIO 256 Frame 3 UIO 256 Frame 4 Common Input Height 5 18 VDC 1 17 33 49 9 34 2 18 34 50 10 35 3 19 35 51 11 36 4 2...

Страница 19: ...GPI OUTPUT NUMBERSa a Dependent on UIO 256 DIP Switch SW1 Settings for Input Output Range as summarized in the UIO 256 manual RELAY CONTACT PIN NUMBERS UIO 256 FRAME 1 UIO 256 FRAME 2 UIO 256 FRAME 3...

Страница 20: ...o relay contact closure for use as a 4 wire call receive indication The DSI 2008 also provides 5 VDC which can be connected to the relay contacts to generate a DC output signal instead of a contact cl...

Страница 21: ...imposed on the audio as follows DSI 2008 Signal Specifications for balanced configuration DSI 2008 Receive 20kHz 100Hz 100mVRMS DSI 2008 Send 20kHz 800Hz 500mVRMS 10 DSI 2008 Signal Specifications for...

Страница 22: ...18 Installation DSI 2008 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05...

Страница 23: ...e call signal option board is attached The DSI 2008 level displays should help to confirm which line is calling 4 Use the level adjust trimmers to fine tune the listen levels NOTE For 4 wire systems o...

Страница 24: ...one GPI To use simply activate the call key and the appropriate talk key Then when a verbal response is received release the call key 4 Optional call signal input using the GPI a In AZedit click GPI I...

Страница 25: ...Remove the top cover This provides access to all internal adjustments 3 For option card installation slide the circuit board out toward the back to remove it from the bottom cover AUX J4B J3B J2B J1B...

Страница 26: ...ion Card Installation To install a Call Signal Option Card in a DSI 2008 that was originally ordered without it do the following 1 Disassemble the DSI 2008 as previously described 2 Assemble the stand...

Страница 27: ...DSI 2008 23 Bosch Security Systems Inc User Manual F 01U 193 295 Rev 05 Notes...

Страница 28: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...

Отзывы: