DBP Digital Beltpack
Cabling | en
11
Bosch Security Systems, LLC
Technical Manual
2021-06 | 01 | F.01U.380.825
4
Cabling
4.1
To OMS
i
Notice!
PoE is not necessary as long as it is on a network that can reach the DBP.
To
cable the DBP to an OMS main station
, do the following:
1.
Using a CAT-5e cable, attach
one end to the PoE IN connector
on the DBP.
2.
Connect the
other end of the cable
to an approved PoE switch.
3.
Using a second CAT-5e cable, connect
one end to the approved PoE switch
.
4.
Connect the
other end to the OMNEO connector
on the OMS device.
PoE Switch
i
Notice!
If using IPedit to configure the connection between the DBP and the OMS, a third cable is
needed to connect the OMNEO port to the PoE switch.