![RTK REact 15 DC Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/rtk/react-15-dc/react-15-dc_installation-and-operating-instructions-manual_1497794007.webp)
REact 15E/15DC - 8070
12/2016
9
Replacement of components
9.1
Replacing the terminal board
Caution: Observe the safety regulations
The actuator must be disconnected from the power supply.
To replace the terminal board, remove the slide (Fig. 11, pos.520).
Remove the board mount from motor plate.
Remove the lever-force switch (Fig. 11, pos. 510).
Remove the terminal board (Fig. 11, pos. 430) from board mount.
Install the new terminal board.
Install the lever-force-switch (Fig. 11, pos. 510) onto the pin of the board mount.
Secure the lever-force-switch with a quick tension disk.
Install the board mount on the motor plate.
Install the slide.
Perform electrical connection according the wiring diagram.
9.2
Motor assembly replacement
Caution: Observe the safety regulations
The actuator must be disconnected from the power supply.
Disconnect the motor with capacitor from terminal board.
Dismantle the BLDC-Controller (BLDC-Motor-Group Pic. 10)
Loosen motor screws or distant bolts (BLDC-Motor-Group Pic. 10)
Replace motor assembly
Screw new motor in place and connect plug.
10
Maintenance, repair
The drive is maintenance-free.
The drive may only be cleaned with mild, soapy water.
Lubricant for the gear and spindle nut:
See technical data in appendix.
11
Notes
Use is purposive. The drive may only be used for the intended purpose. Control and shut off drive for control and Shut/Off valves.
The electric motor can be operated in this drive at a higher ambient temperature (Limit: refer to technical Data).
External metal surfaces can get hot during operation. Do not touch.
A safety distance to hot components must be maintained to avoid heat building up.
Einbau- und Betriebsanleitung
Installation and Operating Instructions
Instrukcja montażu i obsługi