DIP SW5, SW6, SW7, SW8 are used to set the speed when the motor is triggered. Built-in S-type
acceleration and deceleration.

When the switch is closed, the motor accelerates to the set speed.

When the switch is off, the motor decelerates and stops.

4.3 Acceleration selection

DIP SW4 is used to set the acceleration of the motor when it is running.

“Off” means the acceleration gear position “1” and the acceleration is moderate;

“On” means the acceleration gear position “2”, and the acceleration is large.

The default acceleration for the general application is gear 1.

5. Drive working status LED indication

LED status

Drive status

Green indicator is on for long time

Drive not enabled

Green indicator is flickering

Drive working normally

One green indicator and one red indicator Drive overcurrent

One green indicator and two red
indicators

Drive input power overvoltage

One green indicator and three red
indicators

The internal voltage of the drive is
wrong

One green and four red indicators

Tracking error exceeds limits

One green and five red indicators

Encoder phase error

Содержание R60-IO

Страница 1: ...R60 IO User Manual Shenzhen Rtelligent Mechanical Electrical Technology Co Ltd...

Страница 2: ...3 2 Power supply input 4 3 3 Motor connection 5 3 4 Control signal connection 6 3 4 1 IN Port connection for pulse command 6 3 4 2 ENA port for potentiometer speed control 6 4 The setting of DIP switc...

Страница 3: ...O trigger fixed speed motion Power supply 24 48VDC Output Current Up to 5 6 amps peak value Current control PID current control algorithm Micro stepping settings DIP switch settings 16 options Speed r...

Страница 4: ...vertically or horizontally with its front facing forward top facing upward to facilitate cooling During assembly avoid drillings and other foreign matters falling inside the drive During assembly plea...

Страница 5: ...t current control The drive output the voltage to motor by changing the input power into PWM chopping wave when it is working In this case the input power will affect the performance of drive Power se...

Страница 6: ...inductance hybrid stepper motor The common 2 phase stepper motor s lead number are 4 8 and 6 There is only one connection mode for 4 leads motor Series and parallel connection mode are used by 8 leads...

Страница 7: ...f the motor decelerates to a stop When IN1 is off the motor stops running default is this mode S p e e d m o d 2 In1 In2 When IN1 is turned on the motor is triggered to continue to rotate forward when...

Страница 8: ...ent can be custom made 2 1A 1 5A off on on 2 7A 1 9A on off on 3 2A 2 3A off off on 3 8A 2 7A on on off 4 3A 3 1A off on off 4 9A 3 5A on off off 5 6A 4 0A off off off DIP SW1 SW2 SW3 are used to set...

Страница 9: ...tion of the motor when it is running Off means the acceleration gear position 1 and the acceleration is moderate On means the acceleration gear position 2 and the acceleration is large The default acc...

Страница 10: ...SW5 The motor cable is disconnected Check the connection The motor has only one direction Pulse mode error or DIR port damaged Alarm indicator is on The motor connection is wrong Check the motor conne...

Страница 11: ...ause A 1 Warranty period 12 months We provide quality assurance for one year from the date of delivery and free maintenance service for our products during the warranty period A 2 Exclude the followin...

Отзывы: