8. Common faults and troubleshooting

Phenomenon

Possible situations

Solutions

Motor does

not work

Power indicator is off

Check the power supply circuit for normal
power supply

The motor rotor is locked but the
motor does not work

Pulse signal is weak; increase the signal
current to 7-16mA

The speed is too slow

Select the right micro-stepping

Driver is protected

Solve the alarm and re-power

Enable signal problem

Pull up or disconnect the enable signal

Command pulse is incorrect

Check whether the upper computer has
pulse output

The steering

of motor is

wrong

The rotary direction of motor is
reverse

Adjust the DIP SW5

The motor cable is disconnected Check the connection
The motor has only one direction Pulse mode error or DIR port damaged

Alarm

indicator is on

The motor connection is wrong

Check the motor connection

The voltage is too high or too low Check the power supply

The position

or speed is

wrong

The signal is disturbed

Eliminate interference for reliable
grounding

The command input is incorrect

Check the upper computer instructions to
ensure the output is correct

The setting of Pulse per
revolution is wrong

Check the DIP switch status and correctly
connect the switches

Encoder signal is abnormal

Replace the motor and contact the
manufacturer

The Driver

terminal

burned up

Short circuit between terminals

Check power polarity or external short
circuit

Internal resistance between
terminals is too large

Check whether there is any solder ball
due to excessive addition of solder on the
wire connections

9. Guarantee clause

9.1 Warranty period: 12 months

We provide quality assurance for one year from the date of delivery and free maintenance service
for our products during the warranty period.

9.2 Exclude the following:

■ Improper connection, such as the polarity of the power supply is reversed and insert/pull the
motor connection when the power supply is connected.

■ Beyond electrical and environmental requirements.

■ Change the internal device without permission.

Содержание 3R110PLUS

Страница 1: ...3R110 Plus User Manual szruitech com Digital Stepper Driver 3R110PLUS User Manual Shenzhen Rtelligent Mechanical Electrical Technology Co ltd...

Страница 2: ...3 2 3 ALM OUT1 port 4 3 3 USB port 4 4 The setting of DIP switches and operating parameters 5 4 1 The setting of current 5 4 2 Standby current 5 4 3 The setting of pulse per revolution 5 4 4 Pulse com...

Страница 3: ...digital signal input high level can directly receive 24V DC level 1 photoelectric isolation digital signal output maximum withstand voltage 30V maximum input or pull out current 50mA 8 gears can be cu...

Страница 4: ...3 1 Power supply and motor port function description Function Grade Definition Remarks Power supply PE Single phase 220VAC power input AC AC Motor PE Motor PE earth wire Reversing any two wires of U...

Страница 5: ...le IN3 ENA ENA Alarm OUT1 ALM Optocoupler isolation open collector output ALM 3 2 1 PUL DIR port IN1 IN2 By default when operating in external pulse command mode 3R110 PLUS can receive two pulse comma...

Страница 6: ...e motor is in an error state it is automatically turned off The level logic of the enable signal can be set to the opposite At the same time this port can be reused as other functions like IN1 and IN2...

Страница 7: ...the driver is in the enabled state the current remains at the set current SW4 OFF After the driver stops receiving pulses for a certain time it enters the standby state and the current drops to a cert...

Страница 8: ...f 4 4 Pulse command filtering The driver has a built in pulse command smoothing function which can make the motor start more stable SW9 ON enable pulse command filtering SW9 OFF disable pulse command...

Страница 9: ...ase loss alarm function which can detect the phase loss state of the motor during stationary and movement During the operation of the stepper motor due to mechanical reasons the winding wire of the mo...

Страница 10: ...parameters In the absolute position mode the operation state is determined according to the current position and the absolute position set from 70 74 3 Speed mode continuous forward rotation According...

Страница 11: ...e motor is in operation it only responds to the stop command deceleration stop or emergency stop If it is necessary to change the running direction of the motor by command please send the stop command...

Страница 12: ...for the motor to stop and then send the start signal of the other direction The acceleration register 75 and deceleration register 76 are changed during motor operation but the driver will not respond...

Страница 13: ...4 This mode is for the speed defined by the speed table selected by SW5 6 7 8 5 Set the motion parameters you can modify the acceleration deceleration 7 3 IO Control Forward Reverse Same as 7 2 only n...

Страница 14: ...wer supply The position or speed is wrong The signal is disturbed Eliminate interference for reliable grounding The command input is incorrect Check the upper computer instructions to ensure the outpu...

Страница 15: ...ts please follow the procedures shown below 1 Contact our customer service staff to get the rework permission 2 The written document of the Driver failure phenomenon is attached to the goods as well a...

Отзывы: