40
Facing
P1
or CN7’s connector pins, the pinout is:
RS422 or RS485 Serial Port
You may use Setup to configure the first serial port as RS422 or RS485. In this case, you must con-
nect P1or CN7 to an RS422 or RS485 compatible device.
When using RS422 or RS485 mode, you can use the port in either half-duplex (two-wire) or full-
duplex (four-wire) configurations. For half-duplex (2-wire) operation, you must connect RXD+ to
TXD+, and connect RXD- to TXD-.
RS422 and RS485 Mode Pinout
The following table gives the pinout of connector P1or CN7when RS422 or RS485 modes are en-
abled.
9
7
5
3
1
GND
DTR
TXD
RXD
DCD
GND
RI
CTS
RTS
DSR
10
8
6
4
2
NOTE!
A 120 ohm termination resistors is provided on the cpuModule. Termi-
nation is usually necessary on all RS422 receivers and at the ends of the
RS485 bus.
If the termination resistor is required, it can be enabled by closing jump-
er JP1.
Connector
P1
or CN7
in RS-422/485 Mode
Pin
Signal Function
in/out
DB9
1
--
Data Carrier
Detect
--
1
2
--
Data Set Ready
--
6
3
RXD-
Receive Data (-)
in
2
4
TXD+
Transmit Data (+)
out
7
5
TXD-
Transmit Data (-)
out
3
6
RXD+
Receive Data (+)
in
8
7
--
Reseved
--
4
8
--
Reseved
--
9
9,10
gnd
Signal ground
out
5
Содержание cpuModule CMC6686GX
Страница 3: ......
Страница 16: ...15...
Страница 29: ...28...
Страница 30: ...29...
Страница 31: ...30...
Страница 34: ...33 Connector Locations The figure and table below show all connectors and the SSD socket of the cpuModule...
Страница 35: ...34 CMC6686GX Connector Locations...
Страница 36: ...35...
Страница 97: ...96...
Страница 99: ...98...
Страница 102: ...101...
Страница 104: ...103 Default Jumper Settings JP2 2 pin jumper Open no termination...
Страница 105: ...104 Solder Jumpers Solder jumpers are set at the factory and are rarely changed...
Страница 115: ...114...
Страница 117: ...116 Real Time Devices USA Inc P O Box 906 103 Innovation Blvd State College PA 16803 USA Our website www rtdusa com...