108
Common Problems and Solutions
The following table lists some of the common problems you may encounter while using your cpu-
Module, and suggests possible solutions.
If you are having problems with your cpuModule, please review this table
before
contacting techni-
cal support.
Problem
Cause
Solution
cpuModule "will not boot"
no power or wrong polarity
check for correct power on PC/104 bus
connectors
incorrect Setup
(video disabled, etc.)
reboot and press {Del} key to run Setup
defective or mis-connected de-
vice on bus
check for misaligned bus connectors;
remove other cards from stack
cable connected backwards
verify all cables are connected correctly
SSD installed backwards
check for an SSD memory installed in
socket backwards
will not boot from particu-
lar drive or device
device not bootable
use sys command on drive or re-format the
device using the
/s
switch
device not formatted
format drive using
/s
switch
power not connected to boot
drive
connect power cable to floppy or hard
drive
Atmel Flash shows disk
space available, but it can-
not be written
part smaller than 1.44MB was
formatted as 1.44MB; it will
show space available even
when full
ignore "disk space remaining" messages
from DOS
REMEMBER! A bootable disk contains 3
hidden files plus format info, totalling
about 150kB
will not boot from DiskOn-
Chip®
DiskOnChip® is not the only
hard drive in system
disable other hard drive(s) in system
using wrong DiskOnChip®
device (not 32 pin)
change to correct (32 pin) DiskOnChip®
Boot device not set to Hard
disk
run Setup and set boot device to Hard
Drive
Содержание cpuModule CMC6686GX
Страница 3: ......
Страница 16: ...15...
Страница 29: ...28...
Страница 30: ...29...
Страница 31: ...30...
Страница 34: ...33 Connector Locations The figure and table below show all connectors and the SSD socket of the cpuModule...
Страница 35: ...34 CMC6686GX Connector Locations...
Страница 36: ...35...
Страница 97: ...96...
Страница 99: ...98...
Страница 102: ...101...
Страница 104: ...103 Default Jumper Settings JP2 2 pin jumper Open no termination...
Страница 105: ...104 Solder Jumpers Solder jumpers are set at the factory and are rarely changed...
Страница 115: ...114...
Страница 117: ...116 Real Time Devices USA Inc P O Box 906 103 Innovation Blvd State College PA 16803 USA Our website www rtdusa com...