Real Time Automation, Inc. 

150 South Sunny Slope Road Suite 130 

Brookfield WI 53005 

Toll free 1-800-249-1612  

Local (262) 439-4999  

www.rtaautomation.com 

[email protected]

 

Содержание 460MXE

Страница 1: ...460MXE Gateway User Guide 460MXE Gateway User Guide...

Страница 2: ...forth in this agreement may not apply to you No patent liability is assumed by Real Time Automation with respect to use of information circuits equipment or software described in this manual Governmen...

Страница 3: ...a BACnet IP Client or Ethernet IP Client or DeviceNet Master By following this guide you will be able to configure the 460MXE gateway for basic operation You will set the device s network settings an...

Страница 4: ...Data You will need the following tools The 460MXE Gateway The provided CD ROM A Working PC Windows based The Supplied Ethernet crossover cable A 7 30 VDC power source T strip You will also need to ve...

Страница 5: ...60MXE gateway are for Port 0 T strip to be set for RS485 in cluding power Pin 5 Port 1 DB9 is set to RS232 by default If these default port are not compatible with your equipment they can be configure...

Страница 6: ...0MXE gateway are for Port 0 T strip to be set for CAN while Port 1 DB9 is set to RS485 by default If these default port are not compatible with your equipment they can be configured differently For sp...

Страница 7: ...e to the device 2 Using the crossover cable supplied connect the device to the PC NOTE If you are connecting to the device via a hub or a switch use a standard Ethernet cable 3 Insert the provided CD...

Страница 8: ...1 Open an MS DOS Command Prompt 2 Type ipconfig and press enter 3 Note the IP address The previous example was 192 168 0 1 4 To test the communication between the PC and the unit type ping in the prom...

Страница 9: ...2 Type the desired description into the text box 3 Click Save 4 From the Main Page Click the Edit button with the Application Parameters section 5 Enter a 0 to transfer data to BACnet IP 6 Enter a 1 t...

Страница 10: ...xt box 3 Click Save 4 In the Selected Communication Modules row click Edit 5 In the Modbus row click Edit 6 Verify that the Enabled box is checked 7 Response Timeout is set to 500 ms by default and sh...

Страница 11: ...Master Modules 1 From the Main page click Edit in the Client Module Configuration row 2 There are four options for external devices Eaton IQ 250 260 Power Meter Eaton IQ 130 140 150 Eaton Power Xpert...

Страница 12: ...d Generic Remote Modbus Slave Device button 5 Enter a name for the device in the Device Label field to help distinguish between multiple devices 6 In the Slave address enter the address that correspon...

Страница 13: ...e BACnet device to the Modbus slave 3 The Point Type Data Type values will match those of the Modbus slave device 4 Length is the number of data types to be read It is not the number of registers 5 Cl...

Страница 14: ...t corresponds with your Modbus Slave device s 3 In the Device Name field enter a unique name for the device 4 The Description and Locations fields are optional Filling in the fields is recommended to...

Страница 15: ...net IP Server 1 For the Data Out column do the same as Step 8 except use the correct Output Instance Number Length in bytes and Required Pack Interval in milliseconds 2 Click Save when configuration i...

Страница 16: ...ange the device description on the main page in the Description row click Edit Otherwise skip to step 4 2 Type the desired description into the text box 3 Click Save 4 In the Selected Communication Mo...

Страница 17: ...249 1612 460 Gateway Device Line 460MXE Application Parameters 1 Next Application Parameters click Edit 2 460MXE Mapping will display the connection between the tags file names in your PLC to the BAC...

Страница 18: ...The 460MXE Device Summary and Status page will be shown 3 The device drop down menu allows you to switch between the different devices and display their status 4 Under Show you can choose to show onl...

Страница 19: ...1612 460 Gateway Device Line 460MXE Validating Gateway Communication If the Timeout counter or the Error counter are incrementing or a status of Enabled Not Connected refer to the Troubleshooting Tops...

Страница 20: ...ollow these steps 1 From the Main Page click the Utilities button 2 Click Save Configuration to File 3 Click Save 4 Browse to the location you want to save the file 5 Click OK 6 Remove the first devic...

Страница 21: ...ded location 3 For Bacnet IP or Ethernet IP follow steps 4 6 For DeviceNet skip to step 7 4 Attach the Ethernet cable from the BACnet IP Client Ethernet IP Client to the network port on the 460MXE Gat...

Страница 22: ...ng side of the Gateway unit 3 Remove the green T Strip connector Slide the cover off towards the ports The jumpers are just behind the ports 4 Move the jumper shunts to reflect the desired settings 5...

Страница 23: ...3 4 5 Pin Setting GND CANL SHIELD CANH PWR Port 1 DB 9 RS485 1 2 3 4 5 6 7 8 9 Pin Setting NC TX NC NC GND NC TX NC NC Port 0 T Strip CAN 1 2 3 4 5 Pin Setting GND CANL SHIELD CANH PWR Port 1 DB 9 RS...

Страница 24: ...Real Time Automation Inc 150 South Sunny Slope Road Suite 130 Brookfield WI 53005 Toll free 1 800 249 1612 Local 262 439 4999 www rtaautomation com support rtaautomation com...