Push-In Pressure Cell with Piezometer 

Installation Manual 

 
 

LPM0032A 

 

Page 2  

 

 

CAUTION:

 

I

F YOUR 

P

USH

-I

P

RESSURE 

C

ELL DOES NOT HAVE A PIEZOMETER

,

 DO 

NOT PROCEED WITH SATURATION

The following steps outline the procedure for saturating the filter: 

1

 

Remove the filter set screw (Figure 3-1).  

 

  

F

IGURE 

3-1

  

F

ILTER SET SCREW AND FILTER

 

 

CAUTION:

 

T

AKE CARE TO REMOVE ONLY THE FILTER SET SCREW

.

 

R

EMOVING THE 

GLYCOL SET SCREW WILL DAMAGE THE 

P

USH

-I

P

RESSURE 

C

ELL

2

 

Submerge the Push-In Pressure Cell in a bucket of flat water (i.e. water that has 
been sitting for 24 hours). This will fill the space above the diaphragm with water. 

3

 

Let the pressure cell sit in the water to completely saturate the filter. 

4

 

With the pressure cell submerged, slowly replace the filter set screw.  

5

 

The Push-In Pressure Cell should remain submerged until installation. 

I

NSTALLATION 

 

The following instructions outline the steps required to successfully install a Push-In 
Pressure Cell: 

1

 

Drill a pilot hole slightly shorter than the planned installation depth. 

2

 

Connect the Push-In Pressure Cell to a readout. Take an initial reading. 

3

 

Carefully push the Pressure Cell into the pilot hole. Monitor the readout to ensure 
the cell is not over-pressured. 

 

CAUTION:

 

M

ONITOR THE READOUT WHILE THE 

P

RESSURE 

C

ELL IS BEING 

INSTALLED TO PREVENT OVER

-

PRESSURING THE CELL