34
Troubleshooting
Symptom
Cause
No sound.
●
The M-48’s output has been muted by an operation from the M-400 or computer. To cancel the mute
using the M-48, press any of the top panel buttons.
●
The REAC connection has not been established (p. 20). Check whether there might be a problem
with the REAC cable or connections.
●
The settings for the source/level or Source Assign, made on either the M-400 or on a computer, are
inappropriate (p. 21–25).
In situations where an M-400 or a computer is unavailable, the settings for the source/level or Source
Assign can be modified by means of a Recall from memory (p. 31) or a Factory Reset (p. 31).
Can’t adjust the audio that you want to
monitor.
●
The source you’re trying to adjust is not assigned to a group.
Pressing the [SOLO] button does not do
what you expect.
●
The Solo mode setting has been changed from the M-400 or computer (p. 22).
Can’t perform recall/store operations.
●
Recall/store operations on the M-48 have been disabled from the M-400 or computer.
The volume level of the instrument
connected to the AUX IN L/R jack is too
low.
●
You are using a connection cable that contains a built-in resistor. Use a connection cable that does
not contain a resistor.
For EU Countries