The rear of the SFCP Rail will have the following connections:
CONNECTOR X4:
1. FAULT Normally-closed connection
2. FAULT Normally-open connection
3. FAULT Common (engaged an any fault condition)
4. FIRE Normally-closed connection
5. FIRE Normally-open connection
6. FIRE Common (indicates upcoming extinguisher activation)
7. VFC Normally-closed connection
8. VFC Normally-open connection
9. VFC Common (engaged an single/dual* alarm)
(* = dipswitch setting)
CONNECTOR X3:
11. ALARM-
: system ground
12. ALARM +
: switched alarm output, same voltage as input +
13. IGNITION
: 11-32 VDC switched ignition v
14. INPUT-
: input ground
15. INPUT +
: 11-32 VDC input voltage
16. GND
: system ground
CONNECTOR X2:
17. BATTERY -
: battery ground
18. B
: same target voltage as Input +
CONNECTOR X7:
19. EXT HOLD-
: external hold off Input -
20. EXT HOLD +
: external hold off Input +
CONNECTOR X5:
21. GND
: system ground
22. FIRE-EXTINGUISHER -
: output -
23. FIRE-EXTING
: regulated for monitoring
and activation of the extinguisher
CONNECTOR X6:
24. EXT RELEASE-
: external release extinguishing Input
25. EXT R
: external release extinguishing Input
26. ZONE2B
: detector zone2 sense and GND
27. ZONE2A
: detector zone2 +, input power output, 50mA max.
28. ZONE1B
: detector zone1 sense and GND
29. ZONE1A
: detector zone1 +, input power output, 50mA max.