background image

Connect the AC/DC power supply to the SpotDAP unit first, then to the 
correct voltage power source. The SpotDAP unit will automatically turn 
on. The Status LED wil show green. See page 5 for more detail in 
connecting the AC/DC power supply to the SpotDAP unit.

Adjusting the SpotDAP unit volume:

The SpotDAP unit requires audio from a line level external audio 
source, with volume control such as a CD player, DVD player or 
MP3 player.

 

Stop the external audio source.

 

Connect the RCA cables.

 

Turn the external audio sound on.

 

Adjust the external audio source’s volume until you reach  

 

the desired level from the SpotDAP unit.

When the SpotDAP unit detects that incoming signals are signifi-
cantly beyond the input rating of the unit, it automatically lowers 
the signal until the limiter can reduce the input level to within 
operating limits.

Adjusting the SpotDAP EQ settings:

The SpotDAP unit comes programed with 3 selectable EQ 
settings. See page 22 for frequency response plots showing the 
effect of each EQ setting. The factory default is EQ setting #1.

!

NOTE: 

It is always best to begin with a low volume level at the source. 

 

 
 
 
 

OPERATING INSTRUCTIONS

#1 Normal

#2 Bass Cut

#3 Bass Boost

GENERAL SPECIFICATIONS

SYSTEM MODEL Nos. SpotDAP450/SpotDAP460

 

ULTRASONIC & DSP PROCESSING
Carrier Frequency:  

Variable 40 - 50 kHz

Modulation Method:  Proprietary Dynamic Double Sideband

ULTRASONIC EMITTER
Type:    

 

Proprietary Monolithic Film Transducer

AUDIO

Analog Input Section:

Input Impedance: 

            

 

            

 

10k Ohms

A/D 

Converter: 

   16 

bit

Input Connector:  

 

 

2 RCA style connectors

Input Channels:  

 

 

RCA1, RCA2

System Configuration:    

 

Monaural (Two input channels  

     summed 

together 

on 

the 

RCA 

 

     connectors)

Max Input Level Before Clipping:  

160 mVrms x1 channel

     or 

80 

mVrms 

channels

System:

Bandpass Filtering:  

 

 

400Hz to 16KHz

Max Audio SPL Output:   

 

SpotDAP450 85db @ 1KHz/1 meter

 

 

 

 

 

SpotDAP460 91db @ 1KHz/1 meter

POWER AMPLIFICATION (ALL UNITS)

Amplifier 

Type: 

 

   Proprietary 

Modulation 

Amplifier

     (MODAMP®)

7

16

Operating the SpotDAP Unit

OPERATING INSTRUCTIONS

Содержание SpotDAP450

Страница 1: ...ular installation and may be in a position to provide faster service RSF France 45 av Marcel Dassault Parc de la Plaine F 31500 TOULOUSE FRANCE PHONE 33 5 61 20 79 09 E MAIL fab rsf europe com www rsf int com SpotDAP460 SpotDAP450 Directed Audio Sound System Important Safety Instructions 2 3 Unpacking and Inspection Instructions 4 Operating Instructions 5 7 Maintenance 8 Installation Notes 9 10 Tr...

Страница 2: ...GENERAL SPECIFICATIONS Performace Charts cont d 22 SpotDAP450 Frequency Response SpotDAP460 Frequency Response ...

Страница 3: ...urpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinche...

Страница 4: ...els of ultrasound used in the SpotDAP device are not harmful As you would with any loudspeaker it is recommended that you follow prudent safety procedures 21 For best results when operating the SpotDAP unit in Direct Mode pointed directly towards the intended listener it is recommended that you maintain a distance greater than 6 feet 2 meters between the SpotDAP unit and the listener 22 This produ...

Страница 5: ...onnect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Packaging Specifications The packaging for SpotDAP is suitable for common parcel shipment It meets the International Safe Transit Association Procedure 1A pre shipment test specifications Structures and methods utilized in this sy...

Страница 6: ...tically turn on if the AC DC power supply is on The LED on the AC DC power supply will display green if AC power is present For Professional Use Only Low Voltage Directive 73 23 EEC including amendments EMC Directive 89 336 EEC EN60065 1998 Safety for Audio Video Musical Instruments Apparatus for Household Commercial and Similar General Use EN55103 1 Emissions tests EN55022 1998 Conducted Emission...

Страница 7: ...he input level to within limits The Limiter recovery is typically only for a few seconds Adjust source volume level to reduce limiting frequency for the most consistent output volume The Status LED will flash red when the limiter is working ELECTRICAL AC Power Cord Length 1 83 m 6 ft POWER REQUIREMENTS Wattage 100 watts maximum ELECTRICAL RATINGS Input 100V 240V AC Universal power supply 50V 60 Hz...

Страница 8: ...programed with 3 selectable EQ settings See page 22 for frequency response plots showing the effect of each EQ setting The factory default is EQ setting 1 NOTE It is always best to begin with a low volume level at the source OPERATING INSTRUCTIONS 1 Normal 2 Bass Cut 3 Bass Boost GENERAL SPECIFICATIONS SYSTEM MODEL Nos SpotDAP450 SpotDAP460 ULTRASONIC DSP PROCESSING Carrier Frequency Variable 40 5...

Страница 9: ...c areas Audio video conferences in different languages from a single device Point of purchase advertising or language department messaging Providing hearing impaired sections in churches and schools HSS technology can be used anywhere noise abatement requirements preclude general broadcast address but communications are required SpotDAP can transform signs placards and surfaces into virtual speake...

Страница 10: ...mperature Do not expose the SpotDAP unit to direct sunlight for extended periods as the emitter in the SpotDAP unit can be damaged by extremes of heat or cold Observe and maintain the temperature limits as described in the General Specifications section page 18 Humidity Avoid direct exposure to water If the SpotDAP unit is moved and the temperature change causes condensation on the unit allow the ...

Страница 11: ...ranty How do I get SpotDAP service if required Please call RSF Technical Service at 352 49 74 20 40 or email supportl rsf int com to obtain authorization RMA to return the unit for repair or replacement See the warranty card provided with the SpotDAP unit for additional information TROUBLESHOOTING AND FREQUENTLY ASKED QUESTIONS FAQ Select an installation location that is consistent with the variou...

Страница 12: ...art until it hits a reflective surface SpotDAP aplications Troubleshooting If the SpotDAP unit does not generate sound Check green LED is on at SpotDAP I O panel Check that the AC DC power supply is on and the DC plug is in the SpotDAP unit Check the volume level of your external audio source Unplug the AC power check the audio input connectors at the SpotDAP unit and source connection points wait...

Отзывы: