FO-HB9-2022-02 

 

 

FO-HB9 

Internal Blower 

 

 

ATTENTION:  

This fan kit should be installed by a qualified installer

.  

 

DO NOT

  install this blower in fireplaces that are “Clean Face”, making the lower louver area 

inaccessible after installation. 
All wiring must comply with local ordinances and the National Electrical Code. 

WARNING:

  

Prior to installing the blower, ensure all power to the fireplace is disconnected and that the breaker 

is shut off. 

 

 

The internal blower kit will increase the circulation of heated air in the room where the fireplace is installed.  

 

If you desire to distribute the heat in different rooms, please refer to central heating and zone heating kits (FO-

FDHB6-1, FO-FDHC6, FO-FDHCZ1 and FO-FDHCZ2). 

 

This blower kit includes:   

  Blower Assembly 

  Thermal Switch Assembly 

  Variable Speed Switch 

  Wiring 

  Instructions 

Powering the blower:  

Electrician Required 

Power must be brought to the fireplace for the blower to 

operate. 

OPTION 1: THREE PRONG PLUG INSTALLATION 

The three-prong plug setup is best for new installations 

where the internal blower is the only option that will require 

electricity. 
1.  An electrical junction box with a three-prong plug outlet 

should be installed in the bottom of the fireplace by a certified electrician in an accessible location. 

2.  Ensure no wires contact the firebox. 

OPTION 2: TERMINAL BLOCK INSTALLATION 

The terminal block setup is best for replacing existing blowers that are already wired through the terminal block or 

for systems that will utilize the terminal block to power multiple options. For example, systems combining the 

Internal Blower with Central Heating Blower (FO-FDHB6-1) and Central Heating Control (FO-FDHC6). There is no 

terminal block in the Pearl 3600 or Focus 3600 fireplaces. 
1.  Have a certified electrician connect terminals 5 and 6 of the terminal block to a 120V circuit with 14/2 wiring. 

Do not forget to attach the ground wire to the fireplace ground screw which is next to the terminal block. 

2.  Ensure no wires contact the firebox. 

Содержание FO-HB9

Страница 1: ... for the blower to operate OPTION 1 THREE PRONG PLUG INSTALLATION The three prong plug setup is best for new installations where the internal blower is the only option that will require electricity 1 An electrical junction box with a three prong plug outlet should be installed in the bottom of the fireplace by a certified electrician in an accessible location 2 Ensure no wires contact the firebox ...

Страница 2: ... page for the correct orientation and assembly Installation of the Internal Blower 1 Remove the bottom louver of the fireplace If your fireplace has a magnetic bracket located on the right side of the bottom louver opening remove the magnetic bracket If your fireplace is equipped with an ash pan remove the ash pan plug ash pan and the ash pan support by unscrewing the screw located at the back of ...

Страница 3: ...nting plate between the two brackets and face the air outlet upwards The thermal switch should be placed on the inside of the one for the fireplace legs 1 8 from the firebox See below Delta Fusion The floor shield is made of two parts Both parts are screwed together and factory installed to cover the entire floor below the firebox Before installing the internal blower the floor shield must be modi...

Страница 4: ...pan support the ash pan and the ash pan plug if necessary Installation of the thermal switch Install the thermal switch which is a heat activated switch that will turn your blower on and off as the fireplace heats or cools Placement is important Place the thermal switch to the inner right leg or outside air box below the firebox Space the switch 1 8 from the fireplace bottom the magnet will hold t...

Страница 5: ...FO HB9 2022 02 Wiring for terminal block installation Connect the wiring as shown below N Ground 120Vfrom breaker L ...

Отзывы: